Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities

被引:103
|
作者
Ben-David, Tom [1 ]
Waring, Michael S. [1 ]
机构
[1] Drexel Univ, Civil Architectural & Environm Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
Natural ventilation; Particulate matter; Filtration; Indoor outdoor (I/O) ratio; Mechanical economizing; SECONDARY ORGANIC AEROSOL; CO2; CONCENTRATIONS; DAILY MORTALITY; EXPOSURE; OZONE; HEALTH; PARTICULATE; FILTRATION; BUILDINGS; POLLUTION;
D O I
10.1016/j.buildenv.2016.05.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study simulated the impacts of natural versus mechanical ventilation in offices on indoor concentrations of key pollutants, as well as energy usage. A typical office building was modeled in EnergyPlus in fourteen U.S. cities to assess the energy use and airflows delivered by an ideal variable air volume (VAV) system in a range of climates. Two mechanical ventilation strategies (minimum; minimum + economizer control) were modeled, as well as two analogous natural ventilation strategies, which used a fan-driven recirculation hybrid system to maintain setpoints if necessary. Outputted hourly ventilation, recirculation, and infiltration rates were used in an indoor air model with city specific outdoor monitoring data to compute indoor concentrations of carbon monoxide, carbon dioxide, formaldehyde, nitrogen dioxide, ozone, and fine particles (PM2.5). Natural ventilation decreased energy use, due to a wider temperature setpoint band for natural ventilation scenarios and somewhat lower fan energy use. Indoor concentrations and indoor/outdoor (I/O) ratios of all pollutants were similar for analogous strategies, except PM2.5, which was reduced by filtration in the supply air. Median PM2.5 I/O ratios were a factor of 1.2, 2.2, and 6.3 larger for natural versus mechanical ventilation strategies with MERV 8, 11, and 16 filters, respectively. The filtration impact was so strong that PM2,5 I/O ratios differed little between mechanical minimum and economizing strategies, especially as filter efficiency increased. These results can be used to understand tradeoffs of energy and indoor air pollution trends of natural versus mechanical ventilation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:320 / 336
页数:17
相关论文
共 50 条
  • [21] Energy efficiency and indoor air quality of seminar rooms in older buildings with and without mechanical ventilation
    Maas, Stefan
    Antunes, Joel Da Cruz
    Steffgen, Georges
    BAUPHYSIK, 2019, 41 (05) : 243 - 251
  • [22] The Relationship between Mechanical Ventilation, Indoor Air Quality Classes, and Energy Classes in a Romanian Context
    Vasile, Vasilica
    Iordache, Vlad
    Radu, Valentin Mihai
    Dragomir, Claudiu-Sorin
    ATMOSPHERE, 2024, 15 (04)
  • [23] Impact of different mechanical ventilation strategies for night purging on indoor air quality in public buildings
    Lestinen, Sami
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    COLD CLIMATE HVAC & ENERGY 2021, 2021, 246
  • [24] Field measurement of the impact of natural ventilation and portable air cleaners on indoor air quality in three occupant states
    Yin H.
    Li Z.
    Zhai X.
    Ning Y.
    Gao L.
    Cui H.
    Ma Z.
    Li A.
    Energy and Built Environment, 2023, 4 (05): : 601 - 613
  • [25] Impact evaluation of carbon dioxide concentration on energy consumption analyzing indoor air quality
    Butala, Vincenc
    Strojarstvo, 1999, 41 (01): : 27 - 34
  • [26] The impact evaluation of carbon dioxide concentration on energy consumption analyzing indoor air quality
    Butala, V
    STROJARSTVO, 1999, 41 (1-2): : 27 - 34
  • [28] Statistical analysis of natural and mechanical ventilation performance in improving indoor air quality, thermal comfort, and perceived air quality in a healthcare facility
    Gholampour, Marzieh
    Taghipour, Malihe
    Tahavvor, Alireza
    Jafari, Saeed
    INTERNATIONAL JOURNAL OF VENTILATION, 2024,
  • [29] Mechanical ventilation and indoor air quality in recently constructed US homes in marine and cold-dry climates
    Antonopoulos, Chrissi A.
    Rosenberg, Samuel I.
    Zhao, Haoran
    Walker, Iain S.
    Delp, William W.
    Chan, Wanyu Rengie
    Singer, Brett C.
    BUILDING AND ENVIRONMENT, 2023, 245
  • [30] Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system
    Che, Wen Wei
    Tso, Chi Yan
    Sun, Li
    Ip, Danny Y. K.
    Lee, Harry
    Chao, Christopher Y. H.
    Lau, Alexis K. H.
    ENERGY AND BUILDINGS, 2019, 201 : 202 - 215