Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities

被引:103
|
作者
Ben-David, Tom [1 ]
Waring, Michael S. [1 ]
机构
[1] Drexel Univ, Civil Architectural & Environm Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
Natural ventilation; Particulate matter; Filtration; Indoor outdoor (I/O) ratio; Mechanical economizing; SECONDARY ORGANIC AEROSOL; CO2; CONCENTRATIONS; DAILY MORTALITY; EXPOSURE; OZONE; HEALTH; PARTICULATE; FILTRATION; BUILDINGS; POLLUTION;
D O I
10.1016/j.buildenv.2016.05.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study simulated the impacts of natural versus mechanical ventilation in offices on indoor concentrations of key pollutants, as well as energy usage. A typical office building was modeled in EnergyPlus in fourteen U.S. cities to assess the energy use and airflows delivered by an ideal variable air volume (VAV) system in a range of climates. Two mechanical ventilation strategies (minimum; minimum + economizer control) were modeled, as well as two analogous natural ventilation strategies, which used a fan-driven recirculation hybrid system to maintain setpoints if necessary. Outputted hourly ventilation, recirculation, and infiltration rates were used in an indoor air model with city specific outdoor monitoring data to compute indoor concentrations of carbon monoxide, carbon dioxide, formaldehyde, nitrogen dioxide, ozone, and fine particles (PM2.5). Natural ventilation decreased energy use, due to a wider temperature setpoint band for natural ventilation scenarios and somewhat lower fan energy use. Indoor concentrations and indoor/outdoor (I/O) ratios of all pollutants were similar for analogous strategies, except PM2.5, which was reduced by filtration in the supply air. Median PM2.5 I/O ratios were a factor of 1.2, 2.2, and 6.3 larger for natural versus mechanical ventilation strategies with MERV 8, 11, and 16 filters, respectively. The filtration impact was so strong that PM2,5 I/O ratios differed little between mechanical minimum and economizing strategies, especially as filter efficiency increased. These results can be used to understand tradeoffs of energy and indoor air pollution trends of natural versus mechanical ventilation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:320 / 336
页数:17
相关论文
共 50 条
  • [41] Quantifying the impact of housing interventions on indoor air quality and energy consumption using coupled simulation models
    Lindsay J. Underhill
    W. Stuart Dols
    Sharon K. Lee
    M. Patricia Fabian
    Jonathan I. Levy
    Journal of Exposure Science & Environmental Epidemiology, 2020, 30 : 436 - 447
  • [42] Novel demand-controlled optimization of constant-air-volume mechanical ventilation for indoor air quality, durability and energy saving
    Zhang, Sheng
    Ai, Zhengtao
    Lin, Zhang
    APPLIED ENERGY, 2021, 293
  • [43] Impact of Stochastic and Deterministic Behavior on Natural Ventilation: Thermal Comfort and Indoor Air Quality Performances in a Preschool Case Study
    Crespino, Elena
    Campagna, Ludovica Maria
    Carlucci, Francesco
    Martellotta, Francesco
    Fiorito, Francesco
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 4, 2025, 555 : 29 - 34
  • [44] Impact of natural ventilation and outdoor environment on indoor air quality and occupant health in low-income tropical housing
    Kajjoba, Derrick
    Kasedde, Hillary
    Kirabira, John B.
    Wesonga, Racheal
    Mugwanya, Richard
    Lwanyaga, Joseph D.
    Olupot, Peter W.
    ENERGY REPORTS, 2024, 12 : 4184 - 4194
  • [45] Comparison of the indoor air quality in an office operating with natural or mechanical ventilation using short-term intensive pollutant monitoring
    Montgomery, James F.
    Storey, Stefan
    Bartlett, Karen
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (06) : 777 - 787
  • [46] Balancing Indoor Thermal Comfort and Energy Consumption of Air-Conditioning and Mechanical Ventilation Systems via Sparse Firefly Algorithm Optimization
    Zhai, Deqing
    Soh, Yeng Chai
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 1488 - 1494
  • [47] Effects of mechanical ventilation on indoor air quality and occupant health status in energy-efficient homes: A longitudinal field study
    Lim, Ah-Young
    Yoon, Miryoung
    Kim, Eun-Hye
    Kim, Hyun-Ah
    Lee, Myoung Ju
    Cheong, Hae-Kwan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 785
  • [48] Improving the Indoor Air Quality of Office Buildings in the Post-Pandemic Era-Impact on Energy Consumption and Costs
    D'Agostino, Diana
    Minelli, Federico
    Minichiello, Francesco
    Musella, Maddalena
    ENERGIES, 2024, 17 (04)
  • [49] Numerical analysis and evaluation of a tropical classroom for thermal comfort, indoor air quality, and energy consumption using ventilation with air-to-air total heat recovery system (MemHEX)
    Rondina, Aaron John A.
    Cuizon, Roldan P.
    Solomon, Jethro Vince I.
    Enteria, Napoleon A.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2024, 18 (05) : 533 - 578
  • [50] Energy efficient achievement of indoor air quality and thermal comfort using mechanical ventilation heat recovery and solar-energy pre-heating
    Moghadam, Talie Tohidi
    Bruton, Ken
    O'Sullivan, Dominic T. J.
    Norton, Brian
    ENERGY CONVERSION AND MANAGEMENT, 2025, 327