Comparison of Contrast Media and Low-Molecular-Weight Dextran for Frequency-Domain Optical Coherence Tomography

被引:68
|
作者
Ozaki, Yuichi [1 ]
Kitabata, Hironori [1 ]
Tsujioka, Hiroto [1 ]
Hosokawa, Seiki [1 ]
Kashiwagi, Manabu [1 ]
Ishibashi, Kohei [1 ]
Komukai, Kenichi [1 ]
Tanimoto, Takashi [1 ]
Ino, Yasushi [1 ]
Takarada, Shigeho [1 ]
Kubo, Takashi [1 ]
Kimura, Keizo [1 ]
Tanaka, Atsushi [1 ]
Hirata, Kumiko [1 ]
Mizukoshi, Masato [1 ]
Imanishi, Toshio [1 ]
Akasaka, Takashi [1 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
关键词
Contrast media; Intracoronary imaging; Low-molecular-weight dextran L; Optical coherence tomography; ACUTE MYOCARDIAL-INFARCTION; INTRAVASCULAR ULTRASOUND; PLAQUE; MORPHOLOGY;
D O I
10.1253/circj.CJ-11-1122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. Methods and Results: Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar. Conclusions: FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality. (Circ J 2012; 76: 922-927)
引用
收藏
页码:922 / 927
页数:6
相关论文
共 50 条
  • [41] Three-dimensional imaging of fibrous cap by frequency-domain optical coherence tomography
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Costa, Marco A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 547 - 549
  • [42] High-resolution frequency-domain second-harmonic optical coherence tomography
    Su, Jianping
    Tomov, Ivan V.
    Jiang, Yi
    Chen, Zhongping
    APPLIED OPTICS, 2007, 46 (10) : 1770 - 1775
  • [43] Detecting Glaucoma With Visual Fields Derived From Frequency-Domain Optical Coherence Tomography
    Zhang, Xian
    Raza, Ali S.
    Hood, Donald C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3289 - 3296
  • [44] Full-field time-encoded frequency-domain optical coherence tomography
    Povazay, Boris
    Unterhuber, Angelika
    Hermann, Boris
    Sattmann, Harald
    Arthaber, Holger
    Drexler, Wolfgang
    OPTICS EXPRESS, 2006, 14 (17): : 7661 - 7669
  • [45] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Kimura, Masahiro
    Takeda, Teruki
    Tsujino, Yasushi
    Matsumoto, Yuichi
    Yamaji, Masayuki
    Sakaguchi, Tomoko
    Maeda, Keiko
    Mabuchi, Hiroshi
    Murakami, Tomoyuki
    HEART AND VESSELS, 2024, 39 (04) : 310 - 318
  • [46] Frequency-domain Optical Coherence Tomography Findings of Population With High Skin Auto Fluorescence
    Fujino, Yusuke
    Tahara, Satoko
    Naganum, Toru
    Yabushita, Hiroto
    Wang, Wei
    Nakamura, Sunao
    CIRCULATION, 2015, 132
  • [47] Fienup Algorithm With Sparsity Constraints: Application to Frequency-Domain Optical-Coherence Tomography
    Mukherjee, Subhadip
    Seelamantula, Chandra Sekhar
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2014, 62 (18) : 4659 - 4672
  • [48] Feasibility of Frequency-Domain Optical Coherence Tomography for Coronary Stent Imaging: A Matter of Definitions
    Nammas, Wail
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10): : A46 - A46
  • [49] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Masahiro Kimura
    Teruki Takeda
    Yasushi Tsujino
    Yuichi Matsumoto
    Masayuki Yamaji
    Tomoko Sakaguchi
    Keiko Maeda
    Hiroshi Mabuchi
    Tomoyuki Murakami
    Heart and Vessels, 2024, 39 : 310 - 318
  • [50] Computational-imaging-based optical coherence tomography in time- and frequency-domain
    Du, Mengqi
    Eikema, Kjeld S. E.
    Witte, Stefan
    OSA CONTINUUM, 2019, 2 (11): : 3141 - 3152