Comparison of Contrast Media and Low-Molecular-Weight Dextran for Frequency-Domain Optical Coherence Tomography

被引:68
|
作者
Ozaki, Yuichi [1 ]
Kitabata, Hironori [1 ]
Tsujioka, Hiroto [1 ]
Hosokawa, Seiki [1 ]
Kashiwagi, Manabu [1 ]
Ishibashi, Kohei [1 ]
Komukai, Kenichi [1 ]
Tanimoto, Takashi [1 ]
Ino, Yasushi [1 ]
Takarada, Shigeho [1 ]
Kubo, Takashi [1 ]
Kimura, Keizo [1 ]
Tanaka, Atsushi [1 ]
Hirata, Kumiko [1 ]
Mizukoshi, Masato [1 ]
Imanishi, Toshio [1 ]
Akasaka, Takashi [1 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
关键词
Contrast media; Intracoronary imaging; Low-molecular-weight dextran L; Optical coherence tomography; ACUTE MYOCARDIAL-INFARCTION; INTRAVASCULAR ULTRASOUND; PLAQUE; MORPHOLOGY;
D O I
10.1253/circj.CJ-11-1122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. Methods and Results: Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar. Conclusions: FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality. (Circ J 2012; 76: 922-927)
引用
收藏
页码:922 / 927
页数:6
相关论文
共 50 条
  • [21] Optimal sparsifying bases for frequency-domain optical-coherence tomography
    Nayak, Rohit
    Seelamantula, Chandra Sekhar
    OPTICS LETTERS, 2012, 37 (23) : 4907 - 4909
  • [22] Accurate Monte Carlo simulation of frequency-domain optical coherence tomography
    Wang, Yan
    Bai, Li
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (04)
  • [23] Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography
    Leitgeb, R
    Wojtkowski, M
    Kowalczyk, A
    Hitzenberger, CK
    Sticker, M
    Fercher, AF
    OPTICS LETTERS, 2000, 25 (11) : 820 - 822
  • [24] Common-path interferometer for frequency-domain optical coherence tomography
    Vakhtin, AB
    Kane, DJ
    Wood, WR
    Peterson, KA
    APPLIED OPTICS, 2003, 42 (34) : 6953 - 6958
  • [25] Comparison of Contrast Media Versus Hydroxyethyl Starch for Frequency- Domain Optical Coherence Tomography Imaging in Coronary Artery Disease
    Kang, Dong Oh
    Nam, Hyeong Soo
    Kim, Sun Won
    Yoo, Hongki
    Kim, Jin Won
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (16) : S40 - S40
  • [26] Exact and efficient signal reconstruction in frequency-domain optical-coherence tomography
    Seelamantula, Chandra Sekhar
    Villiger, Martin L.
    Leitgeb, Rainer A.
    Unser, Michael
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (07) : 1762 - 1771
  • [27] Performance Analysis of Reconstruction Techniques for Frequency-Domain Optical-Coherence Tomography
    Seelamantula, Chandra Sekhar
    Unser, Michael
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2010, 58 (03) : 1947 - 1951
  • [28] Frequency-domain optical coherence tomography with undetected mid-infrared photons
    Vanselow, Aron
    Kaufmann, Paul
    Zorin, Ivan
    Heise, Bettina
    Chrzanowski, Helen M.
    Ramelow, Sven
    OPTICA, 2020, 7 (12): : 1729 - 1736
  • [29] Frequency-Domain Measurement of Neuronal Activity using Dynamic Optical Coherence Tomography
    Lee, Jonghwan
    Boas, David A.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2643 - 2646
  • [30] Performance analysis of the cepstral technique for frequency-domain optical-coherence tomography
    Sekhar, S. Chandra
    Unser, Michael
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 557 - 560