Comparison of Contrast Media and Low-Molecular-Weight Dextran for Frequency-Domain Optical Coherence Tomography

被引:68
|
作者
Ozaki, Yuichi [1 ]
Kitabata, Hironori [1 ]
Tsujioka, Hiroto [1 ]
Hosokawa, Seiki [1 ]
Kashiwagi, Manabu [1 ]
Ishibashi, Kohei [1 ]
Komukai, Kenichi [1 ]
Tanimoto, Takashi [1 ]
Ino, Yasushi [1 ]
Takarada, Shigeho [1 ]
Kubo, Takashi [1 ]
Kimura, Keizo [1 ]
Tanaka, Atsushi [1 ]
Hirata, Kumiko [1 ]
Mizukoshi, Masato [1 ]
Imanishi, Toshio [1 ]
Akasaka, Takashi [1 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
关键词
Contrast media; Intracoronary imaging; Low-molecular-weight dextran L; Optical coherence tomography; ACUTE MYOCARDIAL-INFARCTION; INTRAVASCULAR ULTRASOUND; PLAQUE; MORPHOLOGY;
D O I
10.1253/circj.CJ-11-1122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. Methods and Results: Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar. Conclusions: FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality. (Circ J 2012; 76: 922-927)
引用
收藏
页码:922 / 927
页数:6
相关论文
共 50 条
  • [31] Volumetric Characterization of Human Coronary Calcification by Frequency-Domain Optical Coherence Tomography
    Mehanna, Emile
    Bezerra, Hiram G.
    Prabhu, David
    Brandt, Eric
    Chamie, Daniel
    Yamamoto, Hirosada
    Attizzani, Guilherme F.
    Tahara, Satoko
    Van Ditzhuijzen, Nienke
    Fujino, Yusuke
    Kanaya, Tomoaki
    Stefano, Gregory
    Wang, Wei
    Gargesha, Madhusudhana
    Wilson, David
    Costa, Marco A.
    CIRCULATION JOURNAL, 2013, 77 (09) : 2334 - 2340
  • [32] Frequency-domain optical coherence tomography based on minimum-phase functions
    Ozcan, A.
    Digonnet, M. J. F.
    Kino, G. S.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [33] Frequency-domain optical coherence tomography with undetected mid-infrared photons
    Institut für Physik, Humboldt-Universität zu Berlin, Newtonstr. 15, Berlin
    12489, Germany
    不详
    4040, Austria
    不详
    12489, Germany
    Optica, 2020, 12 (1729-1736):
  • [34] RENAL RESPONSE TO LOW-MOLECULAR-WEIGHT DEXTRAN
    MATHESON, NA
    IRVIN, TT
    HEDLEY, AJ
    LANCET, 1964, 2 (735): : 501 - +
  • [35] RENAL FAILURE AND LOW-MOLECULAR-WEIGHT DEXTRAN
    HULME, B
    LAWSON, LJ
    BRITISH MEDICAL JOURNAL, 1966, 2 (5527): : 1455 - &
  • [36] RENAL FAILURE AND LOW-MOLECULAR-WEIGHT DEXTRAN
    MATHESON, NA
    BRITISH MEDICAL JOURNAL, 1966, 2 (5523): : 1198 - &
  • [37] Large Axial Range Frequency-Domain Optical Low Coherence Interferometry
    Cerrotta, Santiago
    Morel, Eneas N.
    Alvira, Fernando C.
    Torga, Jorge R.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (02) : 125 - 128
  • [38] RENAL FAILURE AND LOW-MOLECULAR-WEIGHT DEXTRAN
    MORGAN, T
    LITTLE, JM
    OSWALD, I
    GIBSON, MA
    BRITISH MEDICAL JOURNAL, 1967, 1 (5540): : 635 - &
  • [39] Comparison between a time-domain and a frequency-domain system for optical tomography
    Nissila, Ilkka
    Lipiainen, Lauri
    Hebden, Jeremy C.
    Katila, Toivo
    Jennions, David
    Heino, Jenni
    Schweiger, Martin
    Kotilahti, Kalle
    Noponen, Tommi
    Gibson, Adam
    Jarvenpaa, Seppo
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (06)
  • [40] INFLUENCE OF LOW MOLECULAR WEIGHT DEXTRAN ON VASCULAR + INTRAVASCULAR RESPONSES TO CONTRAST MEDIA
    WIEDEMAN, MP
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1964, 92 (03): : 682 - &