Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel-Titanium Instruments

被引:0
|
作者
Omori, Satoshi [1 ]
Ebihara, Arata [1 ]
Hirano, Keiko [1 ]
Kasuga, Yuka [1 ]
Unno, Hayate [1 ]
Nakatsukasa, Taro [1 ]
Kimura, Shunsuke [1 ]
Maki, Keiichiro [1 ]
Hanawa, Takao [2 ]
Okiji, Takashi [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Pulp Biol & Endodont, Div Oral Hlth Sci,Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
[2] Tokyo Med & Dent Univ TMDU, Inst Biomat & Bioengn, Dept Metall Biomat, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
关键词
canal centering ability; heat treatment; nickel-titanium rotary instruments; optimum torque reverse motion; reciprocation; screw-in force; torque; CYCLIC FATIGUE; SHAPING ABILITY; PROTAPER GOLD; ENDODONTIC INSTRUMENTS; MECHANICAL-PROPERTIES; VERTICAL FORCE; RESISTANCE; UNIVERSAL; FILES; RECIPROCATION;
D O I
10.3390/ma15196850
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel-titanium instruments. J-shaped resin canals were instrumented with PTU or PTG using an automated instrumentation device operated with reciprocating rotation [150 degrees clockwise and 30 degrees counterclockwise (R150/30) or 240 degrees clockwise and 120 degrees counterclockwise (R240/120)], optimum torque reverse motion (OTR), or continuous rotation (CR) (n = 10 each). Maximum force and torque were recorded, and canal centering ratios were calculated. Statistical analysis was performed with two-way ANOVA and a Bonferroni test (alpha = 0.05). The results were considered with reference to previous studies on the microstructure of the instruments. The upward force generated by R240/120 and OTR was smaller than that generated by R150/30 and CR in PTG (p < 0.05). The clockwise torque produced by OTR was lower than that produced by R150/30 in PTU and R240/120 and CR in PTG (p < 0.05). R240/120 and OTR induced less canal deviation compared to CR in PTU at 0 mm from the apex (p < 0.05). In conclusion, R240/120 and OTR reduced the screw-in force in PTG and improved the canal centering ability in PTU, which may be associated with the heat treatment-induced microstructural difference of the two instruments.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Factors influencing incidents of complications while using nickel-titanium rotary instruments for root canal treatment
    Madarati, Ahmad A.
    BMC ORAL HEALTH, 2019, 19 (01)
  • [32] Ultrastructural analysis of the root canal walls after preparation with two rotary nickel-titanium endodontic instruments
    Poggio, Claudio
    Dagna, Alberto
    Chiesa, Marco
    Beltrami, Riccardo
    Colombo, Marco
    CONTEMPORARY CLINICAL DENTISTRY, 2014, 5 (03) : 357 - 360
  • [33] Impact of Varying Amplitudes of Upward and Downward Motion on the Torque/Force Generation, Canal-Centering Ability, and Cyclic Fatigue Resistance of Nickel-Titanium Reciprocating Instrument
    Hirano, Keiko
    Kimura, Shunsuke
    Maki, Keiichiro
    Omori, Satoshi
    Ebihara, Arata
    Okiji, Takashi
    APPLIED SCIENCES-BASEL, 2025, 15 (01):
  • [34] Cutting efficiency of conventional and heat-treated nickel-titanium rotary or reciprocating glide path instruments
    Pedulla, E.
    Leanza, G.
    La Rosa, G. R. M.
    Gueli, A. M.
    Pasquale, S.
    Plotino, G.
    Rapisarda, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (03) : 376 - 384
  • [35] Influence of rotational speed on torque/force generation and shaping ability during root canal instrumentation of extracted teeth with continuous rotation and optimum torque reverse motion
    Kyaw, M. S.
    Ebihara, A.
    Kasuga, Y.
    Maki, K.
    Kimura, S.
    Htun, P. H.
    Nakatsukasa, T.
    Okiji, T.
    INTERNATIONAL ENDODONTIC JOURNAL, 2021, 54 (09) : 1614 - 1622
  • [36] Cyclic Fatigue Resistance of Nickel-titanium Rotary Instruments according to the Angle of File Access and Radius of Root Canal
    Pedulla, Eugenio
    La Rosa, Giusy Rita Maria
    Virgillito, Chiara
    Rapisarda, Ernesto
    Kim, Hyeon-Cheol
    Generali, Luigi
    JOURNAL OF ENDODONTICS, 2020, 46 (03) : 431 - 436
  • [37] Effect of preset torque setting on torque/force generation, shaping ability and surface changes of nickel titanium rotary instrument in different root canal curvature locations: An ex vivo study
    Kyaw M.S.
    Ebihara A.
    Iino Y.
    Thu M.
    Maki K.
    Kimura S.
    Htun P.H.
    Okiji T.
    Dental Materials Journal, 2024, 43 (03) : 329 - 337
  • [38] Root Canal Preparation and Enlargement Using Thermally Treated Nickel-Titanium Rotary Systems in Curved Canals
    Barreto Pivoto-Joao, Mariana Mena
    Tanomaru-Filho, Mario
    Pinto, Jader Camilo
    Espir, Camila Galletti
    Guerreiro-Tanomaru, Juliane Maria
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1758 - 1765
  • [39] Microscopic computerized tomographic evaluation of root canal transportation prepared with twisted or ground nickel-titanium rotary instruments
    Freire, Laila Gonzales
    Gavini, Giulio
    Branco-Barletta, Fernando
    Sanches-Cunha, Rodrigo
    dos Santos, Marcelo
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (06): : E143 - E148
  • [40] Analysis of second mesiobuccal root canal instrumentation in maxillary first molars with three nickel-titanium rotary instruments: a micro-computed tomographic study