Cyclic Fatigue Resistance of Nickel-titanium Rotary Instruments according to the Angle of File Access and Radius of Root Canal

被引:39
|
作者
Pedulla, Eugenio [1 ]
La Rosa, Giusy Rita Maria [1 ]
Virgillito, Chiara [1 ]
Rapisarda, Ernesto [1 ]
Kim, Hyeon-Cheol [2 ]
Generali, Luigi [3 ]
机构
[1] Univ Catania, Dept Gen Surg & Surg Med Specialties, Catania, Italy
[2] Pusan Natl Univ, Sch Dent, Dent & Life Sci Inst, Dent Res Inst,Dept Conservat Dent, Yangsan, South Korea
[3] Univ Modena & Reggio Emilia, Dept Surg Med Dent & Morphol Sci Transplant Surg, Modena, Italy
关键词
2Shape; angle of file access; canal curvature; canal radius; cyclic fatigue resistance; HyFlex CM; ENDODONTIC INSTRUMENTS; PROFILE VORTEX; RECIPROC BLUE; FRACTURE; DEFECTS; 2SHAPE; SINGLE;
D O I
10.1016/j.joen.2019.11.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the influences from different access angles and curvature radii on cyclic fatigue resistance of nickel-titanium rotary files. Methods: Two file systems (2Shape [TS; MicroMega, Besancon, France] and HyFlex CM [HCM; Coltene/Whaledent, Allstatten, Switzerland]) were used. A total of 192 instruments of TS #25/.04 (TS1), TS #25/.06 (TS2), HCM #25/.04, and HCM #25/.06 were evaluated at 3 insertion angles (0 degrees, 10 degrees, and 20 degrees) and 2 radii (5 mm and 3 mm) in 16-mm stainless steel artificial canals with a 60 curvature. Cyclic fatigue resistance was determined by the number of cycles to failure (NCF) using a customized testing device. Data were analyzed statistically with the significance level established at 95%. Results: In the 3-mm radius canal, the instruments showed lower cyclic fatigue resistance than in the 5-mm radius canal (P < .05). HCM #25/.06 and all .04 taper instruments had a significant NCF reduction at 20 and 10 in the 3-mm radius canal (P < .05), whereas TS2 showed no significant differences. In the 5-mm radius of curvature, although .06 taper instruments had no significant NCF reduction for each angle tested, .04 taper files exhibited significant NCF reduction when tested at 20 (P < .05). Comparing the same size instruments, HCM had higher NCF than TS (P < .05). Instruments with a .04 taper exhibited higher NCF than the .06 ones with the same heat treatment (P < .05). Conclusions: An inclined insertion into the canals decreased cyclic fatigue resistance of thermal-treated instruments with a .04 taper at all radii of curvature tested. The synergistic effect of a small radius of curvature and access angulation of heat-treated instruments decreases their fatigue resistance.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [1] Impact of Angle of File Access and Location of Canal Curvature on the Dynamic Cyclic Fatigue of Nickel Titanium Rotary Instruments
    Assaf, Dina
    El Seoud, Mohammed Abou
    Kataia, Mohamed
    Saber, Shehabeldin
    EUROPEAN ENDODONTIC JOURNAL, 2024, 9 (02): : 133 - 138
  • [2] Influence of surrounding temperature and angle of file access on cyclic fatigue resistance of two single file nickel-titanium instruments
    La Rosa, Giusy Rita Maria
    Palermo, Carlotta
    Ferlito, Sebastiano
    Isola, Gaetano
    Indelicato, Francesco
    Pedulla, Eugenio
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (02) : 260 - 264
  • [3] A comparison of cyclic fatigue resistance in reciprocating and rotary nickel-titanium instruments
    Wan, Jeffrey
    Rasimick, Brian J.
    Musikant, Barry L.
    Deutsch, Allan S.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (03) : 122 - 127
  • [4] Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments
    Capar, Ismail Davut
    Ertas, Huseyin
    Arslan, Hakan
    AUSTRALIAN ENDODONTIC JOURNAL, 2015, 41 (01) : 24 - 28
  • [5] The effect of instrument material, taper and degree of root canal curvature on cyclic fatigue of rotary nickel-titanium instruments
    Saber, Shehab El Din Mohamed
    Abou Seeda, Marwa Mohammad Aly
    Hassanien, Ehab
    ENDO-ENDODONTIC PRACTICE TODAY, 2013, 7 (01): : 59 - 64
  • [6] Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation
    Pedulla, E.
    Lizio, A.
    Scibilia, M.
    Grande, N. M.
    Plotino, G.
    Boninelli, S.
    Rapisarda, E.
    Lo Giudice, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (02) : 194 - 201
  • [7] Response: Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary instruments
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1101 - 1101
  • [8] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [9] A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments
    Plotino, Gianluca
    Grande, Nicola M.
    Cordaro, Massimo
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2009, 35 (11) : 1469 - 1476
  • [10] Cyclic Fatigue Resistance of Rotary Nickel-Titanium Instruments Submitted to Nitrogen Ion Implantation
    Gavini, Giulio
    Pessoa, Oscar Faciola
    Barletta, Fernando Branco
    Vasconcellos, M. A. Z.
    Caldeira, Celso Luiz
    JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1183 - 1186