Cyclic Fatigue Resistance of Nickel-titanium Rotary Instruments according to the Angle of File Access and Radius of Root Canal

被引:39
|
作者
Pedulla, Eugenio [1 ]
La Rosa, Giusy Rita Maria [1 ]
Virgillito, Chiara [1 ]
Rapisarda, Ernesto [1 ]
Kim, Hyeon-Cheol [2 ]
Generali, Luigi [3 ]
机构
[1] Univ Catania, Dept Gen Surg & Surg Med Specialties, Catania, Italy
[2] Pusan Natl Univ, Sch Dent, Dent & Life Sci Inst, Dent Res Inst,Dept Conservat Dent, Yangsan, South Korea
[3] Univ Modena & Reggio Emilia, Dept Surg Med Dent & Morphol Sci Transplant Surg, Modena, Italy
关键词
2Shape; angle of file access; canal curvature; canal radius; cyclic fatigue resistance; HyFlex CM; ENDODONTIC INSTRUMENTS; PROFILE VORTEX; RECIPROC BLUE; FRACTURE; DEFECTS; 2SHAPE; SINGLE;
D O I
10.1016/j.joen.2019.11.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the influences from different access angles and curvature radii on cyclic fatigue resistance of nickel-titanium rotary files. Methods: Two file systems (2Shape [TS; MicroMega, Besancon, France] and HyFlex CM [HCM; Coltene/Whaledent, Allstatten, Switzerland]) were used. A total of 192 instruments of TS #25/.04 (TS1), TS #25/.06 (TS2), HCM #25/.04, and HCM #25/.06 were evaluated at 3 insertion angles (0 degrees, 10 degrees, and 20 degrees) and 2 radii (5 mm and 3 mm) in 16-mm stainless steel artificial canals with a 60 curvature. Cyclic fatigue resistance was determined by the number of cycles to failure (NCF) using a customized testing device. Data were analyzed statistically with the significance level established at 95%. Results: In the 3-mm radius canal, the instruments showed lower cyclic fatigue resistance than in the 5-mm radius canal (P < .05). HCM #25/.06 and all .04 taper instruments had a significant NCF reduction at 20 and 10 in the 3-mm radius canal (P < .05), whereas TS2 showed no significant differences. In the 5-mm radius of curvature, although .06 taper instruments had no significant NCF reduction for each angle tested, .04 taper files exhibited significant NCF reduction when tested at 20 (P < .05). Comparing the same size instruments, HCM had higher NCF than TS (P < .05). Instruments with a .04 taper exhibited higher NCF than the .06 ones with the same heat treatment (P < .05). Conclusions: An inclined insertion into the canals decreased cyclic fatigue resistance of thermal-treated instruments with a .04 taper at all radii of curvature tested. The synergistic effect of a small radius of curvature and access angulation of heat-treated instruments decreases their fatigue resistance.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [21] Effect of different axial speed patterns on cyclic fatigue resistance of rotary nickel-titanium instruments
    Thu, Myint
    Ebihara, Arata
    Maki, Keiichiro
    Nishijo, Miki
    Kimura, Shunsuke
    Nakatsukasa, Taro
    Kyaw, Moe Sandar
    Okiji, Takashi
    BMC ORAL HEALTH, 2022, 22 (01)
  • [22] Dynamic cyclic and torsional fatigue resistance of TruNatomy compared with different nickel-titanium rotary instruments
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    Elshazli, Alaa H.
    AUSTRALIAN ENDODONTIC JOURNAL, 2020, 46 (02) : 226 - 233
  • [23] Effect of different axial speed patterns on cyclic fatigue resistance of rotary nickel-titanium instruments
    Myint Thu
    Arata Ebihara
    Keiichiro Maki
    Miki Nishijo
    Shunsuke Kimura
    Taro Nakatsukasa
    Moe Sandar Kyaw
    Takashi Okiji
    BMC Oral Health, 22
  • [24] Effects of Electropolishing Surface Treatment on the Cyclic Fatigue Resistance of BioRace Nickel-Titanium Rotary Instruments
    Lopes, Helio P.
    Elias, Carlos N.
    Vieira, Victor T. L.
    Moreira, Edson J. L.
    Marques, Raquel V. L.
    Machado de Oliveira, Julio C.
    Debelian, Gilberto
    Siqueira, Jose F., Jr.
    JOURNAL OF ENDODONTICS, 2010, 36 (10) : 1653 - 1657
  • [25] Cyclic Fatigue Resistance of Rotary and Reciprocating Nickel-Titanium Instruments Subjected to Static and Dynamic Tests
    Thu, Myint
    Ebihara, Arata
    Maki, Keiichiro
    Miki, Nishijo
    Okiji, Takashi
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1752 - 1757
  • [26] Comparison of Cyclic Fatigue Resistance of Three Different Rotary Nickel-Titanium Instruments Designed for Retreatment
    Inan, Ugur
    Aydin, Cumhur
    JOURNAL OF ENDODONTICS, 2012, 38 (01) : 108 - 111
  • [27] Static and Dynamic Cyclic Fatigue Resistance of Nickel-Titanium Rotary Instruments in a Double-Curved Stainless Steel Artificial Canal
    Le, Hoang-Lan-Anh
    Tran, Thuan-Loc
    Nguyen, Thu-Thuy
    Pham, Tran-Lan-Khue
    Pham, Van-Khoa
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [28] Effect of Repeated Autoclaving on Cyclic Fatigue of Three Nickel-Titanium Rotary Instruments
    Elbatal, Laila M.
    El Batouty, Kariem Mostafa
    Obeid, Maram Mohamed
    ENDO-ENDODONTIC PRACTICE TODAY, 2016, 10 (01): : 15 - 22
  • [29] In vitro cyclic fatigue analysis of different endodontic Nickel-Titanium rotary instruments
    Cutro, Giuseppe
    Amateis, Valentina
    Provenzano, Salvatore C.
    Cusimano, Paolo
    Cumbo, Enzo M.
    Gallina, Giuseppe
    GIORNALE ITALIANO DI ENDODONZIA, 2012, 26 (03): : 145 - 149
  • [30] An In Vitro Cyclic Fatigue Analysis of Different Endodontic Nickel-Titanium Rotary Instruments
    Bhagabati, Nilav
    Yadav, Seema
    Talwar, Sangeeta
    JOURNAL OF ENDODONTICS, 2012, 38 (04) : 515 - 518