Cyclic Fatigue Resistance of Nickel-titanium Rotary Instruments according to the Angle of File Access and Radius of Root Canal

被引:39
|
作者
Pedulla, Eugenio [1 ]
La Rosa, Giusy Rita Maria [1 ]
Virgillito, Chiara [1 ]
Rapisarda, Ernesto [1 ]
Kim, Hyeon-Cheol [2 ]
Generali, Luigi [3 ]
机构
[1] Univ Catania, Dept Gen Surg & Surg Med Specialties, Catania, Italy
[2] Pusan Natl Univ, Sch Dent, Dent & Life Sci Inst, Dent Res Inst,Dept Conservat Dent, Yangsan, South Korea
[3] Univ Modena & Reggio Emilia, Dept Surg Med Dent & Morphol Sci Transplant Surg, Modena, Italy
关键词
2Shape; angle of file access; canal curvature; canal radius; cyclic fatigue resistance; HyFlex CM; ENDODONTIC INSTRUMENTS; PROFILE VORTEX; RECIPROC BLUE; FRACTURE; DEFECTS; 2SHAPE; SINGLE;
D O I
10.1016/j.joen.2019.11.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the influences from different access angles and curvature radii on cyclic fatigue resistance of nickel-titanium rotary files. Methods: Two file systems (2Shape [TS; MicroMega, Besancon, France] and HyFlex CM [HCM; Coltene/Whaledent, Allstatten, Switzerland]) were used. A total of 192 instruments of TS #25/.04 (TS1), TS #25/.06 (TS2), HCM #25/.04, and HCM #25/.06 were evaluated at 3 insertion angles (0 degrees, 10 degrees, and 20 degrees) and 2 radii (5 mm and 3 mm) in 16-mm stainless steel artificial canals with a 60 curvature. Cyclic fatigue resistance was determined by the number of cycles to failure (NCF) using a customized testing device. Data were analyzed statistically with the significance level established at 95%. Results: In the 3-mm radius canal, the instruments showed lower cyclic fatigue resistance than in the 5-mm radius canal (P < .05). HCM #25/.06 and all .04 taper instruments had a significant NCF reduction at 20 and 10 in the 3-mm radius canal (P < .05), whereas TS2 showed no significant differences. In the 5-mm radius of curvature, although .06 taper instruments had no significant NCF reduction for each angle tested, .04 taper files exhibited significant NCF reduction when tested at 20 (P < .05). Comparing the same size instruments, HCM had higher NCF than TS (P < .05). Instruments with a .04 taper exhibited higher NCF than the .06 ones with the same heat treatment (P < .05). Conclusions: An inclined insertion into the canals decreased cyclic fatigue resistance of thermal-treated instruments with a .04 taper at all radii of curvature tested. The synergistic effect of a small radius of curvature and access angulation of heat-treated instruments decreases their fatigue resistance.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [31] Influence of Rotational Speed on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Lopes, Helio P.
    Ferreira, Alessandra A. P.
    Elias, Carlos N.
    Moreira, Edson J. L.
    Machado de Oliveira, Julio C.
    Siqueira, Jose F., Jr.
    JOURNAL OF ENDODONTICS, 2009, 35 (07) : 1013 - 1016
  • [32] Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency
    Bui, Tung B.
    Mitchell, John C.
    Baumgartner, J. Craig
    JOURNAL OF ENDODONTICS, 2008, 34 (02) : 190 - 193
  • [33] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (11) : 1034 - 1039
  • [34] Effect of nickel-titanium alloys on root canal preparation and on mechanical properties of rotary instruments
    Vivan, Rodrigo Ricci
    Sanches Marques Costa, Vanessa Abreu
    Conti, Leticia Citelli
    Duque, Jussaro Alves
    Bramante, Clovis Monteiro
    So, Marcus Vinicius Reis
    Alcalde, Murilo Priori
    Hungaro Duarte, Marco Antonio
    BRAZILIAN ORAL RESEARCH, 2022, 36
  • [35] Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals
    Bahia, MGA
    Buono, VTL
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (02): : 249 - 255
  • [36] Shaping Ability and Debris Extrusion of New Rotary Nickel-Titanium Root Canal Instruments
    Buerklein, Sebastian
    Donnermeyer, David
    Hentschel, Tim Julian
    Schaefer, Edgar
    MATERIALS, 2021, 14 (05) : 1 - 8
  • [37] Influence of Continuous or Reciprocating Motion on Cyclic Fatigue Resistance of 4 Different Nickel-Titanium Rotary Instruments
    Pedulla, Eugenio
    Grande, Nicola M.
    Plotino, Gianluca
    Gambarini, Gianluca
    Rapisarda, Ernesto
    JOURNAL OF ENDODONTICS, 2013, 39 (02) : 258 - 261
  • [38] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Lee, S. W.
    Park, Y. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1100 - 1100
  • [39] Effect of Torsional Loading of Nickel-Titanium Instruments on Cyclic Fatigue Resistance
    Cheung, Gary Shun-Pan
    Oh, Seung-Hei
    Ha, Jung-Hong
    Kim, Sung Kyo
    Park, Se-Hee
    Kim, Hyeon-Cheol
    JOURNAL OF ENDODONTICS, 2013, 39 (12) : 1593 - 1597
  • [40] Effect of movement kinematics on the cyclic fatigue resistance of nickel-titanium instruments
    Karatas, E.
    Arslan, H.
    Buker, M.
    Seckin, F.
    Capar, I. D.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (04) : 361 - 364