Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel-Titanium Instruments

被引:0
|
作者
Omori, Satoshi [1 ]
Ebihara, Arata [1 ]
Hirano, Keiko [1 ]
Kasuga, Yuka [1 ]
Unno, Hayate [1 ]
Nakatsukasa, Taro [1 ]
Kimura, Shunsuke [1 ]
Maki, Keiichiro [1 ]
Hanawa, Takao [2 ]
Okiji, Takashi [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Pulp Biol & Endodont, Div Oral Hlth Sci,Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
[2] Tokyo Med & Dent Univ TMDU, Inst Biomat & Bioengn, Dept Metall Biomat, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
关键词
canal centering ability; heat treatment; nickel-titanium rotary instruments; optimum torque reverse motion; reciprocation; screw-in force; torque; CYCLIC FATIGUE; SHAPING ABILITY; PROTAPER GOLD; ENDODONTIC INSTRUMENTS; MECHANICAL-PROPERTIES; VERTICAL FORCE; RESISTANCE; UNIVERSAL; FILES; RECIPROCATION;
D O I
10.3390/ma15196850
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel-titanium instruments. J-shaped resin canals were instrumented with PTU or PTG using an automated instrumentation device operated with reciprocating rotation [150 degrees clockwise and 30 degrees counterclockwise (R150/30) or 240 degrees clockwise and 120 degrees counterclockwise (R240/120)], optimum torque reverse motion (OTR), or continuous rotation (CR) (n = 10 each). Maximum force and torque were recorded, and canal centering ratios were calculated. Statistical analysis was performed with two-way ANOVA and a Bonferroni test (alpha = 0.05). The results were considered with reference to previous studies on the microstructure of the instruments. The upward force generated by R240/120 and OTR was smaller than that generated by R150/30 and CR in PTG (p < 0.05). The clockwise torque produced by OTR was lower than that produced by R150/30 in PTU and R240/120 and CR in PTG (p < 0.05). R240/120 and OTR induced less canal deviation compared to CR in PTU at 0 mm from the apex (p < 0.05). In conclusion, R240/120 and OTR reduced the screw-in force in PTG and improved the canal centering ability in PTU, which may be associated with the heat treatment-induced microstructural difference of the two instruments.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Comparison of root canal preparations and apical transportation between nickel-titanium rotary files and stainless steel hand instruments
    Varela Patino, Purificacion
    Pedrosa, Loreto
    Cantatore, Giuseppe
    Bahilo, Jose
    Ruiz-Pinon, Manuel
    Rivas, Berta
    Martin-Biedma, Benjamin
    ENDO-ENDODONTIC PRACTICE TODAY, 2012, 6 (01): : 45 - 49
  • [42] Root Canal Preparation of Mandibular Molars with 3 Nickel-Titanium Rotary Instruments: A Micro-Computed Tomographic Study
    Zhao, Dan
    Shen, Ya
    Peng, Bin
    Haapasalo, Markus
    JOURNAL OF ENDODONTICS, 2014, 40 (11) : 1860 - 1864
  • [43] Efficacy of Different Nickel-Titanium Instruments in Removing Gutta-percha during Root Canal Retreatment
    Ozyurek, Taha
    Demiryurek, Ebru Ozsezer
    JOURNAL OF ENDODONTICS, 2016, 42 (04) : 646 - 649
  • [44] Cyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use
    Kamali, S. G.
    Turkaydin, D.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (02) : 247 - 253
  • [45] EFFECT OF NICKEL-TITANIUM ENGINE-DRIVEN INSTRUMENT ROTATIONAL SPEED ON ROOT-CANAL MORPHOLOGY
    POULSEN, WB
    DOVE, SB
    DELRIO, CE
    JOURNAL OF ENDODONTICS, 1995, 21 (12) : 609 - 612
  • [46] Effect of Different Heat-treated Nickel-Titanium Files on Vertical Root Fracture Resistance
    Furuncuoglu, Fatma
    Kalyoncuoglu, Elif
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 (02): : 157 - 163
  • [47] Evaluation of apically extruded debris during the canal preparation using new heat-treated nickel-titanium files in curved canals
    Duzgun, Salih
    Topcuoglu, Huseyin Sinan
    Kahraman, Omur
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (01) : 54 - 58
  • [48] Cyclic fatigue and torsional resistance of heat-treated One Curve compared with different nickel-titanium rotary instruments
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    ENDO-ENDODONTIC PRACTICE TODAY, 2019, 13 (03): : 247 - 253
  • [49] Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments
    Alfawaz, Hussam
    Alqedairi, Abdullah
    Alsharekh, Hala
    Almuzaini, Eman
    Alzahrani, Shand
    Jamleh, Ahmed
    JOURNAL OF ENDODONTICS, 2018, 44 (10) : 1563 - 1566
  • [50] Various heat-treated nickel-titanium rotary instruments evaluated in S-shaped simulated resin canals
    Gu, Yu
    Kum, Kee-Yeon
    Perinpanayagam, Hiran
    Kim, Christine
    Kum, Daniel Jaewon
    Lim, Sang-Min
    Chang, Seok-Woo
    Baek, Seung-Ho
    Zhu, Qiang
    Yoo, Yeon-Jee
    JOURNAL OF DENTAL SCIENCES, 2017, 12 (01) : 14 - 20