Root Canal Preparation and Enlargement Using Thermally Treated Nickel-Titanium Rotary Systems in Curved Canals

被引:6
|
作者
Barreto Pivoto-Joao, Mariana Mena [1 ]
Tanomaru-Filho, Mario [1 ]
Pinto, Jader Camilo [1 ]
Espir, Camila Galletti [1 ]
Guerreiro-Tanomaru, Juliane Maria [1 ]
机构
[1] Sao Paulo State Univ, Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
关键词
Endodontic treatment; micro-computed tomography; nickel-titanium endodontic instruments; root canal preparation; CYCLIC FATIGUE RESISTANCE; MICRO-COMPUTED TOMOGRAPHY; SHAPING ABILITY; HYFLEX EDM; APICAL ENLARGEMENT; FILE; MOLARS; INSTRUMENTS; RECIPROC; MORPHOLOGY;
D O I
10.1016/j.joen.2020.08.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate root canal preparation and apical enlargement of curved canals using rotary heat-treated and heat/surface-treated systems by micro computed tomographic imaging. Methods: Curved mesial root canals (n = 48) of mandibular molars (20 degrees-40 degrees) were prepared using ProDesign Logic (PDL; Easy Equipamentos Odontologicos, Belo Horizonte, MG, Brazil) 25/.01 and 25/.06 or HyFlex EDM (HFEDM) 10/.05, HyFlex CM 20/.04, and HFEDM 25/.08. Apical enlargement was performed using PDL 40/.05 or HFEDM 40/.04. Scanning (9 lim) was performed before and after preparation and after apical enlargement using micro computed tomographic imaging. Volume, percentage of volume increase, debris, untouched root canal surface, and centering ability were analyzed. Statistical analysis was performed using Mann-Whitney, Wilcoxon, and unpaired t tests (alpha = .05). Results: HFEDM promoted a higher volume increase of the root canals than PDL after preparation and after apical enlargement (P < .05). The apical enlargement promoted a significant decrease in debris and untouched surface in both groups (P < .05). The percentage of debris and untouched surface were similar between HFEDM and PDL after preparation and after apical enlargement (P > .05). Both systems promoted centered canals (P > .05). Conclusions: HFEDM instruments promoted greater volume of the root canal than PDL. However, the cleaning ability of the instruments was similar. The apical increase up to size 40 with both instruments provided less debris and untouched surfaces and allowed centralization of the curved root canals.
引用
下载
收藏
页码:1758 / 1765
页数:8
相关论文
共 50 条
  • [1] Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals
    Capar, Ismail Davut
    Ertas, Huseyin
    Ok, Evren
    Arslan, Hakan
    Ertas, Elif Tarim
    JOURNAL OF ENDODONTICS, 2014, 40 (06) : 852 - 856
  • [2] Comparative Study of 6 Rotary Nickel-Titanium Systems and Hand Instrumentation for Root Canal Preparation in Severely Curved Root Canals of Extracted Teeth
    Celik, Davut
    Tasdemir, Tamer
    Er, Kursat
    JOURNAL OF ENDODONTICS, 2013, 39 (02) : 278 - 282
  • [3] A COMPARISON OF TRANSPORTATION OF THREE NICKEL-TITANIUM ENDODONTICS ROTARY SYSTEMS IN SEVERELY CURVED ROOT CANALS
    Donyavi, Z.
    Shahriari, S.
    Esmaeilzadeh, M.
    Ghanei, S.
    ANNALS OF DENTAL SPECIALTY, 2018, 6 (01): : 6 - 11
  • [4] Evaluation of a New Nickel-Titanium System to Create the Glide Path in Root Canal Preparation of Curved Canals
    D'Amario, Maurizio
    Baldi, Mario
    Petricca, Roberto
    De Angelis, Francesco
    El Abed, Rashid
    D'Arcangelo, Camillo
    JOURNAL OF ENDODONTICS, 2013, 39 (12) : 1581 - 1584
  • [5] A microcomputed tomography evaluation of the shaping ability of three thermally-treated nickel-titanium rotary file systems in curved canals
    Huang, Zhuwei
    Quan, Jingjing
    Liu, Jia
    Zhang, Wen
    Zhang, Xiaolei
    Hu, Xiaoli
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (01) : 325 - 334
  • [6] Final root canal preparation form with different rotary nickel-titanium systems.
    Marroquín, BB
    Hagedorn, B
    Lingelbach, H
    Willershausen, B
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A391 - A391
  • [7] Lifespan of One Nickel-Titanium Rotary File with Reciprocating Motion in Curved Root Canals
    You, Sung-Yeop
    Bae, Kwang-Shik
    Baek, Seung-Ho
    Kum, Kee-Yeon
    Shon, Won-Jun
    Lee, WooCheol
    JOURNAL OF ENDODONTICS, 2010, 36 (12) : 1991 - 1994
  • [8] Curved molar root canal preparations using Hero 642 rotary nickel-titanium instruments
    Bertrand, MF
    Lupi-Pégurier, L
    Médioni, E
    Muller, M
    Bolla, M
    INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (08) : 631 - 636
  • [9] Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments
    Buerklein, S.
    Boerjes, L.
    Schaefer, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (05) : 470 - 476
  • [10] Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation
    Guelzow, A
    Stamm, O
    Martus, P
    Kielbassa, AM
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (10) : 743 - 752