Root Canal Preparation and Enlargement Using Thermally Treated Nickel-Titanium Rotary Systems in Curved Canals

被引:6
|
作者
Barreto Pivoto-Joao, Mariana Mena [1 ]
Tanomaru-Filho, Mario [1 ]
Pinto, Jader Camilo [1 ]
Espir, Camila Galletti [1 ]
Guerreiro-Tanomaru, Juliane Maria [1 ]
机构
[1] Sao Paulo State Univ, Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
关键词
Endodontic treatment; micro-computed tomography; nickel-titanium endodontic instruments; root canal preparation; CYCLIC FATIGUE RESISTANCE; MICRO-COMPUTED TOMOGRAPHY; SHAPING ABILITY; HYFLEX EDM; APICAL ENLARGEMENT; FILE; MOLARS; INSTRUMENTS; RECIPROC; MORPHOLOGY;
D O I
10.1016/j.joen.2020.08.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate root canal preparation and apical enlargement of curved canals using rotary heat-treated and heat/surface-treated systems by micro computed tomographic imaging. Methods: Curved mesial root canals (n = 48) of mandibular molars (20 degrees-40 degrees) were prepared using ProDesign Logic (PDL; Easy Equipamentos Odontologicos, Belo Horizonte, MG, Brazil) 25/.01 and 25/.06 or HyFlex EDM (HFEDM) 10/.05, HyFlex CM 20/.04, and HFEDM 25/.08. Apical enlargement was performed using PDL 40/.05 or HFEDM 40/.04. Scanning (9 lim) was performed before and after preparation and after apical enlargement using micro computed tomographic imaging. Volume, percentage of volume increase, debris, untouched root canal surface, and centering ability were analyzed. Statistical analysis was performed using Mann-Whitney, Wilcoxon, and unpaired t tests (alpha = .05). Results: HFEDM promoted a higher volume increase of the root canals than PDL after preparation and after apical enlargement (P < .05). The apical enlargement promoted a significant decrease in debris and untouched surface in both groups (P < .05). The percentage of debris and untouched surface were similar between HFEDM and PDL after preparation and after apical enlargement (P > .05). Both systems promoted centered canals (P > .05). Conclusions: HFEDM instruments promoted greater volume of the root canal than PDL. However, the cleaning ability of the instruments was similar. The apical increase up to size 40 with both instruments provided less debris and untouched surfaces and allowed centralization of the curved root canals.
引用
下载
收藏
页码:1758 / 1765
页数:8
相关论文
共 50 条
  • [41] Quality of preparation of oval distal root canals in mandibular molars using nickel-titanium instruments
    Rödig, T
    Hülsmann, M
    Mühge, M
    Schäfers, F
    INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (11) : 919 - 928
  • [42] Efficiency of Different Nickel-Titanium Endodontic File Systems in Cleaning and Apical Transportation of Simulated Curved Root Canals
    Ivacson, Andrea Csinszka Kovacs
    Pacurar, Mariana
    Monea, Monica
    Kovacs, Monika
    Pop, M.
    Bechir, Anamaria
    Borda, Angela
    REVISTA DE CHIMIE, 2017, 68 (05): : 957 - 961
  • [43] Analysis of Torque and Force Induced by Rotary Nickel-Titanium Instruments during Root Canal Preparation: A Systematic Review
    Thu, Myint
    Ebihara, Arata
    Adel, Sherif
    Okiji, Takashi
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [44] Torque during canal instrumentation using rotary nickel-titanium files
    Sattapan, B
    Palamara, JEA
    Messer, HH
    JOURNAL OF ENDODONTICS, 2000, 26 (03) : 156 - 160
  • [45] Efficiency and complications in root canal retreatment using nickel titanium rotary file with continuous rotation, reciprocating, or adaptive motion in curved root canals: a laboratory investigation
    Benjaporn Tantiwanichpun
    Sirinya Kulvitit
    BMC Oral Health, 23
  • [46] Factors influencing incidents of complications while using nickel-titanium rotary instruments for root canal treatment
    Ahmad A. Madarati
    BMC Oral Health, 19
  • [47] Efficiency and complications in root canal retreatment using nickel titanium rotary file with continuous rotation, reciprocating, or adaptive motion in curved root canals: a laboratory investigation
    Tantiwanichpun, Benjaporn
    Kulvitit, Sirinya
    BMC ORAL HEALTH, 2023, 23 (01)
  • [48] Factors influencing incidents of complications while using nickel-titanium rotary instruments for root canal treatment
    Madarati, Ahmad A.
    BMC ORAL HEALTH, 2019, 19 (01)
  • [49] Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals
    Madureira, Rui Goncalves
    Navarro, Leopoldo Forner
    Llena, Mari Carmen
    Costa, Marcia
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 109 (02): : E136 - E144
  • [50] Shaping ability of lightspeed rotary nickel-titanium instruments in simulated root canals .1.
    Thompson, SA
    Dummer, PMH