摘要
Introduction: The purpose of this study was to evaluate root canal preparation and apical enlargement of curved canals using rotary heat-treated and heat/surface-treated systems by micro computed tomographic imaging. Methods: Curved mesial root canals (n = 48) of mandibular molars (20 degrees-40 degrees) were prepared using ProDesign Logic (PDL; Easy Equipamentos Odontologicos, Belo Horizonte, MG, Brazil) 25/.01 and 25/.06 or HyFlex EDM (HFEDM) 10/.05, HyFlex CM 20/.04, and HFEDM 25/.08. Apical enlargement was performed using PDL 40/.05 or HFEDM 40/.04. Scanning (9 lim) was performed before and after preparation and after apical enlargement using micro computed tomographic imaging. Volume, percentage of volume increase, debris, untouched root canal surface, and centering ability were analyzed. Statistical analysis was performed using Mann-Whitney, Wilcoxon, and unpaired t tests (alpha = .05). Results: HFEDM promoted a higher volume increase of the root canals than PDL after preparation and after apical enlargement (P < .05). The apical enlargement promoted a significant decrease in debris and untouched surface in both groups (P < .05). The percentage of debris and untouched surface were similar between HFEDM and PDL after preparation and after apical enlargement (P > .05). Both systems promoted centered canals (P > .05). Conclusions: HFEDM instruments promoted greater volume of the root canal than PDL. However, the cleaning ability of the instruments was similar. The apical increase up to size 40 with both instruments provided less debris and untouched surfaces and allowed centralization of the curved root canals.
引用
下载
收藏
页码:1758 / 1765
页数:8
相关论文
共 50 条
  • [31] Root Canal Shaping Using Rotary Nickel-Titanium Files in Preclinical Dental Education in Turkey
    Unal, Gul Celik
    Maden, Murat
    Orhan, Ekim Onur
    Saritekin, Erdal
    Teke, Anil
    JOURNAL OF DENTAL EDUCATION, 2012, 76 (04) : 509 - 513
  • [32] A comparison of the minimum canal wall thickness remaining following preparation using two nickel-titanium rotary systems
    Garala, M
    Kuttler, S
    Hardigan, P
    Steiner-Carmi, R
    Dorn, S
    INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (09) : 636 - 642
  • [33] Conditioning of root canal anatomy on static and dynamics of nickel-titanium rotary instruments
    Di Giuseppe, Italo
    Di Giuseppe, Davide
    Malagnino, Vito Antonio
    Silla, Enrico Paolo
    Somma, Francesco
    GIORNALE ITALIANO DI ENDODONZIA, 2015, 29 (02): : 58 - 64
  • [34] A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals
    Yun, HH
    Kim, SK
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 95 (02): : 228 - 233
  • [35] Influence of optimum torque reverse motion on dentinal cracks after root canal preparation with two nickel-titanium rotary systems
    Khallaf, Maram
    Hassan, Reham
    CONTEMPORARY CLINICAL DENTISTRY, 2022, 13 (02) : 183 - 188
  • [36] Comparative Analysis of Three Nickel-Titanium Rotary Files in Severely Curved L-Shaped Root Canals: Preparation Time, Aberrations, and Fracture Rates
    Almnea, Raid Abdullah
    Albeaji, Sadun Mohammad Al Ageel
    Alelyani, Ahmed Ali
    AlHarith, Dalia
    Alshahrani, Abdulmajeed Saeed
    Al Malwi, Ahmed Abdullah
    Alobaid, Mohammed A.
    Al Moaleem, Mohammed M.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2024, 16 : 1 - 9
  • [37] A comparison of stainless steel and nickel-titanium K-files in curved root canals
    Chan, AWK
    Cheung, GSP
    INTERNATIONAL ENDODONTIC JOURNAL, 1996, 29 (06) : 370 - 375
  • [38] Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems
    Liu, Wenzhe
    Wu, Buling
    JOURNAL OF ENDODONTICS, 2016, 42 (02) : 299 - 303
  • [39] Evaluation of Apically Extruded Debris from Curved Root Canal Filling Removal Using 5 Nickel-Titanium Systems
    Canakci, Burhan Can
    Ustun, Yakup
    Er, Ozgur
    Sen, Ozgur Genc
    JOURNAL OF ENDODONTICS, 2016, 42 (07) : 1101 - 1104
  • [40] An in vitro comparison of canal preparation using two automated rotary nickel-titanium instrumentation techniques
    Jardine, SJ
    Gulabivala, K
    INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (04) : 381 - 391