Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks

被引:30
|
作者
Trong, M. L. Dao [1 ]
Diezi, C. [1 ]
Goerres, G. [2 ]
Helmy, N. [1 ]
机构
[1] Burgerspital, Dept Orthoped Surg, CH-4500 Solothurn, Switzerland
[2] Burgerspital, Dept Radiol, CH-4500 Solothurn, Switzerland
关键词
Unicompartmental knee arthroplasty; Computed tomography; Alignment; Rotation; Patient-specific cutting blocks; IMPLANT POSITION; ACCURACY; ALIGNMENT; REPLACEMENT; PROSTHESES; WEAR;
D O I
10.1007/s00167-014-2839-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Unicompartmental knee arthroplasty (UKA) has recently regained popularity for the treatment of osteoarthritis of the knee. Numerous authors have cited alignment as an important prognostic factor in the survival of UKA. Limb alignment affects not only the longevity of UKA by influencing wear of polyethylene, but also affects the unreplaced contralateral compartment. Malpositioning of the components may result in unequal wear patterns, thus further leading to early failure and additionally influencing clinical outcome as well. However, there is a lack of techniques to assure a high accuracy of the implant positioning. In this study, we investigated tibia component alignment of 28 medial UKAs implanted with patient-specific cutting blocks. Three patients were excluded due to bad imaging. Measurements of tibial component alignment from postoperatively computed tomography (CT) scans were compared to respective CT-based preoperative plannings to assess the accuracy of implant positioning. Our results show excellent high accuracy of tibial implant position in tibial varus/valgus (Delta 0.3A degrees A A +/- A 1.7A degrees), posterior slope (Delta 1.1A degrees A A +/- A 2.6A degrees) and external rotation (Delta 1.5A degrees A A +/- A 3.3A degrees). We conclude that patient-specific cutting blocks improve the accuracy of tibia component positioning in unicompartmental knee arthroplasty. Case series with no comparison group, Level IV.
引用
收藏
页码:1993 / 1998
页数:6
相关论文
共 50 条
  • [1] Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks
    M. L. Dao Trong
    C. Diezi
    G. Goerres
    N. Helmy
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1993 - 1998
  • [2] Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting
    Mai Lan Dao Trong
    Diezi, Christian
    Goerres, Gerhard
    Helmy, Nader
    SWISS MEDICAL WEEKLY, 2013, 143 : 4S - 4S
  • [3] Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component
    Masaichi Sotozawa
    Ken Kumagai
    Shunsuke Yamada
    Shuntaro Nejima
    Yutaka Inaba
    Journal of Orthopaedic Surgery and Research, 17
  • [4] Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component
    Sotozawa, Masaichi
    Kumagai, Ken
    Yamada, Shunsuke
    Nejima, Shuntaro
    Inaba, Yutaka
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [5] Patient-specific implants for lateral unicompartmental knee arthroplasty
    Marco K. Demange
    Arvind Von Keudell
    Christian Probst
    Hiroshi Yoshioka
    Andreas H. Gomoll
    International Orthopaedics, 2015, 39 : 1519 - 1526
  • [6] Patient-specific implants for lateral unicompartmental knee arthroplasty
    Demange, Marco K.
    Von Keudell, Arvind
    Probst, Christian
    Yoshioka, Hiroshi
    Gomoll, Andreas H.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (08) : 1519 - 1526
  • [7] Computed tomography-based patient-specific cutting guides used for positioning of the femoral component of implants during unicompartmental knee arthroplasty: a cadaver study
    Junfeng Cai
    Min Ma
    Wen Zeng
    Shuling Luo
    Feng Yuan
    Feng Yin
    BMC Surgery, 23
  • [8] Computed tomography-based patient-specific cutting guides used for positioning of the femoral component of implants during unicompartmental knee arthroplasty: a cadaver study
    Cai, Junfeng
    Ma, Min
    Zeng, Wen
    Luo, Shuling
    Yuan, Feng
    Yin, Feng
    BMC SURGERY, 2023, 23 (01)
  • [9] Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty?
    Nunley, Ryan M.
    Ellison, Bradley S.
    Ruh, Erin L.
    Williams, Brandon M.
    Foreman, Keith
    Ford, Adrienne D.
    Barrack, Robert L.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (03) : 889 - 894
  • [10] Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation
    B. Kerens
    A. M. Leenders
    M. G. M. Schotanus
    B. Boonen
    W. E. Tuinebreijer
    P. J. Emans
    B. Jong
    N. P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1823 - 1830