Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks

被引:30
|
作者
Trong, M. L. Dao [1 ]
Diezi, C. [1 ]
Goerres, G. [2 ]
Helmy, N. [1 ]
机构
[1] Burgerspital, Dept Orthoped Surg, CH-4500 Solothurn, Switzerland
[2] Burgerspital, Dept Radiol, CH-4500 Solothurn, Switzerland
关键词
Unicompartmental knee arthroplasty; Computed tomography; Alignment; Rotation; Patient-specific cutting blocks; IMPLANT POSITION; ACCURACY; ALIGNMENT; REPLACEMENT; PROSTHESES; WEAR;
D O I
10.1007/s00167-014-2839-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Unicompartmental knee arthroplasty (UKA) has recently regained popularity for the treatment of osteoarthritis of the knee. Numerous authors have cited alignment as an important prognostic factor in the survival of UKA. Limb alignment affects not only the longevity of UKA by influencing wear of polyethylene, but also affects the unreplaced contralateral compartment. Malpositioning of the components may result in unequal wear patterns, thus further leading to early failure and additionally influencing clinical outcome as well. However, there is a lack of techniques to assure a high accuracy of the implant positioning. In this study, we investigated tibia component alignment of 28 medial UKAs implanted with patient-specific cutting blocks. Three patients were excluded due to bad imaging. Measurements of tibial component alignment from postoperatively computed tomography (CT) scans were compared to respective CT-based preoperative plannings to assess the accuracy of implant positioning. Our results show excellent high accuracy of tibial implant position in tibial varus/valgus (Delta 0.3A degrees A A +/- A 1.7A degrees), posterior slope (Delta 1.1A degrees A A +/- A 2.6A degrees) and external rotation (Delta 1.5A degrees A A +/- A 3.3A degrees). We conclude that patient-specific cutting blocks improve the accuracy of tibia component positioning in unicompartmental knee arthroplasty. Case series with no comparison group, Level IV.
引用
收藏
页码:1993 / 1998
页数:6
相关论文
共 50 条
  • [31] DEFORMATION AND LOOSENING OF THE TIBIAL COMPONENT IN KNEE ARTHROPLASTY WITH UNICOMPARTMENTAL ENDOPROSTHESES
    KNUTSON, K
    JONSSON, G
    ANDERSEN, JL
    LARUSDOTTIR, H
    LIDGREN, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (06): : 667 - 673
  • [32] Improved tibial cutting accuracy in knee arthroplasty
    Macdonald, W
    Styf, J
    Carlsson, LV
    Jacobsson, CM
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) : 807 - 812
  • [33] A Novel Technique for Varus Tibial Cutting for Oxford Unicompartmental Knee Arthroplasty
    Hiranaka, Takafumi
    Tanaka, Toshikazu
    Fujishiro, Takaaki
    Okimura, Kenjiro
    Shigemoto, Rika
    Araki, Shotaro
    Okada, Ryo
    Nako, Ryohei
    Okamoto, Koji
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (04) : 554 - 557
  • [34] Improved Radiographic Outcomes With Patient-Specific Total Knee Arthroplasty
    Ivie, Conrad B.
    Probst, Patrick J.
    Bal, Amrit K.
    Stannard, James T.
    Crist, Brett D.
    Bal, B. Sonny
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2100 - 2103
  • [35] The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study
    Alvand, Abtin
    Khan, Tanvir
    Jenkins, Cathy
    Rees, Jonathan L.
    Jackson, William F.
    Dodd, Christopher A. F.
    Murray, David W.
    Price, Andrew J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) : 1662 - 1670
  • [36] Unicompartmental Knee Arthroplasty with Use of Novel Patient-Specific Resurfacing Implants and Personalized Jigs
    Fitz, Wolfgang
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 69 - 76
  • [37] The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study
    Abtin Alvand
    Tanvir Khan
    Cathy Jenkins
    Jonathan L. Rees
    William F. Jackson
    Christopher A. F. Dodd
    David W. Murray
    Andrew J. Price
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1662 - 1670
  • [38] Early catastrophic tibial component wear after unicompartmental knee arthroplasty
    Palmer, SH
    Morrison, PJM
    Ross, AC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (350) : 143 - 148
  • [39] Mobile bearing orbit on the tibial component in Oxford unicompartmental knee arthroplasty
    Suda, Yoshihito
    Hiranaka, Takafumi
    Kamenaga, Tomoyuki
    Fujishiro, Takaaki
    Okamoto, Koji
    Matsumoto, Tomoyuki
    KNEE, 2023, 42 : 136 - 142
  • [40] Influence of patient selection, component positioning and surgeon's caseload on the outcome of unicompartmental knee arthroplasty
    Schraknepper, Johannes
    Dimitriou, Dimitris
    Helmy, Naeder
    Hasler, Julian
    Radzanowski, Stephan
    Flury, Andreas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (06) : 807 - 813