Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks

被引:30
|
作者
Trong, M. L. Dao [1 ]
Diezi, C. [1 ]
Goerres, G. [2 ]
Helmy, N. [1 ]
机构
[1] Burgerspital, Dept Orthoped Surg, CH-4500 Solothurn, Switzerland
[2] Burgerspital, Dept Radiol, CH-4500 Solothurn, Switzerland
关键词
Unicompartmental knee arthroplasty; Computed tomography; Alignment; Rotation; Patient-specific cutting blocks; IMPLANT POSITION; ACCURACY; ALIGNMENT; REPLACEMENT; PROSTHESES; WEAR;
D O I
10.1007/s00167-014-2839-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Unicompartmental knee arthroplasty (UKA) has recently regained popularity for the treatment of osteoarthritis of the knee. Numerous authors have cited alignment as an important prognostic factor in the survival of UKA. Limb alignment affects not only the longevity of UKA by influencing wear of polyethylene, but also affects the unreplaced contralateral compartment. Malpositioning of the components may result in unequal wear patterns, thus further leading to early failure and additionally influencing clinical outcome as well. However, there is a lack of techniques to assure a high accuracy of the implant positioning. In this study, we investigated tibia component alignment of 28 medial UKAs implanted with patient-specific cutting blocks. Three patients were excluded due to bad imaging. Measurements of tibial component alignment from postoperatively computed tomography (CT) scans were compared to respective CT-based preoperative plannings to assess the accuracy of implant positioning. Our results show excellent high accuracy of tibial implant position in tibial varus/valgus (Delta 0.3A degrees A A +/- A 1.7A degrees), posterior slope (Delta 1.1A degrees A A +/- A 2.6A degrees) and external rotation (Delta 1.5A degrees A A +/- A 3.3A degrees). We conclude that patient-specific cutting blocks improve the accuracy of tibia component positioning in unicompartmental knee arthroplasty. Case series with no comparison group, Level IV.
引用
收藏
页码:1993 / 1998
页数:6
相关论文
共 50 条
  • [41] Influence of patient selection, component positioning and surgeon’s caseload on the outcome of unicompartmental knee arthroplasty
    Johannes Schraknepper
    Dimitris Dimitriou
    Naeder Helmy
    Julian Hasler
    Stephan Radzanowski
    Andreas Flury
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 807 - 813
  • [42] Component position alignment with patient-specific jigs in total knee arthroplasty
    Moopanar, Terence R.
    Amaranath, Jeevaka E.
    Sorial, Rami M.
    ANZ JOURNAL OF SURGERY, 2014, 84 (09) : 628 - 632
  • [43] Varus or valgus positioning of the tibial component of a unicompartmental fixed-bearing knee arthroplasty does not increase wear
    Matthias Woiczinski
    Christian Schröder
    Alexander Paulus
    Manuel Kistler
    Volkmar Jansson
    Peter E. Müller
    Patrick Weber
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 3016 - 3021
  • [44] Varus or valgus positioning of the tibial component of a unicompartmental fixed-bearing knee arthroplasty does not increase wear
    Woiczinski, Matthias
    Schroeder, Christian
    Paulus, Alexander
    Kistler, Manuel
    Jansson, Volkmar
    Mueller, Peter E.
    Weber, Patrick
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (09) : 3016 - 3021
  • [45] Improved tibial component rotation in TKA using patient-specific instrumentation
    Thomas J. Heyse
    Carsten O. Tibesku
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 697 - 701
  • [46] Improved tibial component rotation in TKA using patient-specific instrumentation
    Heyse, Thomas J.
    Tibesku, Carsten O.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (05) : 697 - 701
  • [47] Tibial baseplate positioning in robotic-assisted and conventional unicompartmental knee arthroplasty
    MacCallum K.P.
    Danoff J.R.
    Geller J.A.
    European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (1) : 93 - 98
  • [48] Contact stresses in a patient-specific unicompartmental knee replacement
    Van den Heever, David J.
    Scheffer, Cornie
    Erasmus, Pieter J.
    Dillon, Edwin M.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5113 - 5116
  • [49] Contact stresses in a patient-specific unicompartmental knee replacement
    van den Heever, Dawie J.
    Scheffer, Cornie
    Erasmus, Pieter
    Dillon, Edwin
    CLINICAL BIOMECHANICS, 2011, 26 (02) : 159 - 166
  • [50] Accuracy of Patient-specific Jigs for Glenoid Component Positioning in Total Shoulder Arthroplasty
    Wheeler, Luke P.
    Booth, Grant
    Delport, Sven
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2018, 19 (01): : 24 - 28