Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks

被引:30
|
作者
Trong, M. L. Dao [1 ]
Diezi, C. [1 ]
Goerres, G. [2 ]
Helmy, N. [1 ]
机构
[1] Burgerspital, Dept Orthoped Surg, CH-4500 Solothurn, Switzerland
[2] Burgerspital, Dept Radiol, CH-4500 Solothurn, Switzerland
关键词
Unicompartmental knee arthroplasty; Computed tomography; Alignment; Rotation; Patient-specific cutting blocks; IMPLANT POSITION; ACCURACY; ALIGNMENT; REPLACEMENT; PROSTHESES; WEAR;
D O I
10.1007/s00167-014-2839-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Unicompartmental knee arthroplasty (UKA) has recently regained popularity for the treatment of osteoarthritis of the knee. Numerous authors have cited alignment as an important prognostic factor in the survival of UKA. Limb alignment affects not only the longevity of UKA by influencing wear of polyethylene, but also affects the unreplaced contralateral compartment. Malpositioning of the components may result in unequal wear patterns, thus further leading to early failure and additionally influencing clinical outcome as well. However, there is a lack of techniques to assure a high accuracy of the implant positioning. In this study, we investigated tibia component alignment of 28 medial UKAs implanted with patient-specific cutting blocks. Three patients were excluded due to bad imaging. Measurements of tibial component alignment from postoperatively computed tomography (CT) scans were compared to respective CT-based preoperative plannings to assess the accuracy of implant positioning. Our results show excellent high accuracy of tibial implant position in tibial varus/valgus (Delta 0.3A degrees A A +/- A 1.7A degrees), posterior slope (Delta 1.1A degrees A A +/- A 2.6A degrees) and external rotation (Delta 1.5A degrees A A +/- A 3.3A degrees). We conclude that patient-specific cutting blocks improve the accuracy of tibia component positioning in unicompartmental knee arthroplasty. Case series with no comparison group, Level IV.
引用
收藏
页码:1993 / 1998
页数:6
相关论文
共 50 条
  • [21] Accuracy of tibial component positioning in the robotic arm assisted versus conventional unicompartmental knee arthroplasty
    Thilak, Jai
    Thadi, Mohan
    Mane, Prajwal P.
    Sharma, Anubhav
    Mohan, Vipin
    Babu, Balu C.
    JOURNAL OF ORTHOPAEDICS, 2020, 22 : 367 - 371
  • [22] Adequate Positioning of the Tibial Component Is Key to Avoiding Bearing Impingement in Oxford Unicompartmental Knee Arthroplasty
    Kamenaga, Tomoyuki
    Hiranaka, Takafumi
    Takayama, Koji
    Tsubosaka, Masanori
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    JOURNAL OF ARTHROPLASTY, 2019, 34 (11): : 2606 - 2613
  • [23] Accuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty
    Helmy, Naeder
    Mai Lan Dao Trong
    Kuehnel, Stefanie P.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [24] Rotational component alignment in patient-specific total knee arthroplasty compared with conventional cutting instrument
    Chanalithichai, Nuttawut
    Tammachote, Nattapol
    Jitapunkul, Chane
    Kanitnate, Supakit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (06): : 1297 - 1304
  • [25] Rotational component alignment in patient-specific total knee arthroplasty compared with conventional cutting instrument
    Nuttawut Chanalithichai
    Nattapol Tammachote
    Chane Jitapunkul
    Supakit Kanitnate
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1297 - 1304
  • [26] Patient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis
    Viola Freigang
    Markus Rupp
    Christian Pfeifer
    Michael Worlicek
    Stefan Radke
    Stephan Deckelmann
    Volker Alt
    Florian Baumann
    BMC Musculoskeletal Disorders, 21
  • [27] Patient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis
    Freigang, Viola
    Rupp, Markus
    Pfeifer, Christian
    Worlicek, Michael
    Radke, Stefan
    Deckelmann, Stephan
    Alt, Volker
    Baumann, Florian
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [28] Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty
    Inui, Hiroshi
    Taketomi, Shuji
    Yamagami, Ryota
    Sanada, Takaki
    Tanaka, Sakae
    KNEE, 2016, 23 (01): : 173 - 176
  • [29] UNICOMPARTMENTAL ARTHROPLASTY OF THE KNEE - CADAVER STUDY OF TIBIAL COMPONENT PLACEMENT
    MOLLER, JT
    WEETH, RE
    KELLER, JO
    ACTA ORTHOPAEDICA SCANDINAVICA, 1985, 56 (02): : 115 - 119
  • [30] CT based patient-specific cutting blocks for total knee arthroplasty: technique and preliminary radiological results
    Mueller, Daniel Andreas
    Meyer, Dominik
    Koch, Peter
    SWISS MEDICAL WEEKLY, 2011, 141 : 16S - 16S