NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings

被引:55
|
作者
Mendes, Luciano B. [1 ,2 ,3 ]
Ogink, Nico W. M. [2 ]
Edouard, Nadege [4 ]
van Dooren, Hendrik Jan C. [2 ]
Tinoco, Ilda de Fatima F. [3 ]
Mosquera, Julio [2 ]
机构
[1] Inst Agr & Fisheries Res ILVO, Technol & Food Sci Unit T&V, B-9820 Merelbeke, Belgium
[2] Wageningen UR Livestock Res, NL-6700 AC Wageningen, Netherlands
[3] Univ Fed Vicosa, Dept Agr Engn, BR-36570000 Vicosa, MG, Brazil
[4] INRA AgrocampusOuest, PEGASE UMR1348, F-35590 St Gilles, France
来源
SENSORS | 2015年 / 15卷 / 05期
关键词
ventilation rate; CO2 mass balance; dairy barn; open-path laser; photo acoustic spectroscopy; OPEN-PATH FTIR; AMMONIA EMISSIONS; PHOTOACOUSTIC-SPECTROSCOPY; AIR EXCHANGE; LAYING HENS; CO2; DAIRY; BALANCE; HOUSES; VALIDATION;
D O I
10.3390/s150511239
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo-Acoustic Spectroscope (PAS) Gas Monitor and an Open-Path laser (OP-laser). First, calibrations for the NDIR sensors were obtained in the laboratory. Then, the NDIR sensors were placed in a dairy cow barn for comparison with the PAS and OP-laser methods. The main conclusions were: (a) in order to represent the overall barn CO2 concentration of the dairy cow barn, the number of NDIR sensors to be accounted for average concentration calculation was dependent on barn length and on barn area occupation; and (b) the NDIR CO2 sensors are suitable for multi-point monitoring of CO2 concentrations in NV livestock barns, being a feasible alternative for the PAS and the OP-laser methods to monitor single-point or averaged spatial CO2 concentrations in livestock barns.
引用
收藏
页码:11239 / 11257
页数:19
相关论文
共 50 条
  • [41] An intelligent gas sensor application for the discrimination of Forane 134a and carbon dioxide gas concentrations: The effect of relative humidity
    Delpha, C
    Lumbreras, M
    Siadat, M
    ETFA 2001: 8TH IEEE INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION, VOL 2, PROCEEDINGS, 2001, : 393 - 399
  • [42] Determination of the Interzonal Airflows in Naturally Ventilated Dwellings Based on Concentration Measurements of the Metabolic Carbon Dioxide
    Bulinska, Anna
    Bulinski, Zbigniew
    ENERGIES, 2023, 16 (01)
  • [43] Gas analyzer for continuous monitoring of carbon dioxide in gas streams
    Marzouk, Sayed A. M.
    Al-Marzouqi, Mohamed H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) : 398 - 404
  • [44] Amperometric sensor for monitoring of dissolved carbon dioxide in seawater
    Ishiji, T
    Chipman, DW
    Takahashi, T
    Takahashi, K
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 265 - 269
  • [45] Flexible sensor patch for continuous carbon dioxide monitoring
    Hetzler, Zach
    Wang, Yan
    Krafft, Danny
    Jamalzadegan, Sina
    Overton, Laurie
    Kudenov, Michael W.
    Ligler, Frances S.
    Wei, Qingshan
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [46] A FIBEROPTIC CARBON-DIOXIDE SENSOR FOR FERMENTATION MONITORING
    UTTAMLAL, M
    WALT, DR
    BIO-TECHNOLOGY, 1995, 13 (06): : 597 - 601
  • [47] End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates
    Tingay, David Gerald
    Mun, Kwok Sean
    Perkins, Elizabeth Jean
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2013, 98 (02): : F161 - F164
  • [48] An electrochemical sensor for determination of the methane and carbon dioxide concentrations in biogas
    Kalyakin, Anatoly S.
    Volkov, Alexander N.
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2025, 169
  • [49] Fluorescence optical sensor for low concentrations of dissolved carbon dioxide
    Muller, B
    Hauser, PC
    ANALYST, 1996, 121 (03) : 339 - 343
  • [50] Sequestering carbon dioxide into complex structures of naturally occurring gas hydrates
    Park, Youngjune
    Kim, Do-Youn
    Lee, Jong-Won
    Huh, Dae-Gee
    Park, Keun-Pil
    Lee, Jaehyoung
    Lee, Huen
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (34) : 12690 - 12694