NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings

被引:55
|
作者
Mendes, Luciano B. [1 ,2 ,3 ]
Ogink, Nico W. M. [2 ]
Edouard, Nadege [4 ]
van Dooren, Hendrik Jan C. [2 ]
Tinoco, Ilda de Fatima F. [3 ]
Mosquera, Julio [2 ]
机构
[1] Inst Agr & Fisheries Res ILVO, Technol & Food Sci Unit T&V, B-9820 Merelbeke, Belgium
[2] Wageningen UR Livestock Res, NL-6700 AC Wageningen, Netherlands
[3] Univ Fed Vicosa, Dept Agr Engn, BR-36570000 Vicosa, MG, Brazil
[4] INRA AgrocampusOuest, PEGASE UMR1348, F-35590 St Gilles, France
来源
SENSORS | 2015年 / 15卷 / 05期
关键词
ventilation rate; CO2 mass balance; dairy barn; open-path laser; photo acoustic spectroscopy; OPEN-PATH FTIR; AMMONIA EMISSIONS; PHOTOACOUSTIC-SPECTROSCOPY; AIR EXCHANGE; LAYING HENS; CO2; DAIRY; BALANCE; HOUSES; VALIDATION;
D O I
10.3390/s150511239
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo-Acoustic Spectroscope (PAS) Gas Monitor and an Open-Path laser (OP-laser). First, calibrations for the NDIR sensors were obtained in the laboratory. Then, the NDIR sensors were placed in a dairy cow barn for comparison with the PAS and OP-laser methods. The main conclusions were: (a) in order to represent the overall barn CO2 concentration of the dairy cow barn, the number of NDIR sensors to be accounted for average concentration calculation was dependent on barn length and on barn area occupation; and (b) the NDIR CO2 sensors are suitable for multi-point monitoring of CO2 concentrations in NV livestock barns, being a feasible alternative for the PAS and the OP-laser methods to monitor single-point or averaged spatial CO2 concentrations in livestock barns.
引用
收藏
页码:11239 / 11257
页数:19
相关论文
共 50 条
  • [31] A fiberoptic sensor for tissue carbon dioxide monitoring
    Davenport, John J.
    Hickey, Michelle
    Phillips, Justin P.
    Kyriacou, Panicos A.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7942 - 7945
  • [32] Optimization of Sampling Positions for Measuring Ventilation Rates in Naturally Ventilated Buildings Using Tracer Gas
    Shen, Xiong
    Zong, Chao
    Zhang, Guoqiang
    SENSORS, 2012, 12 (09) : 11966 - 11988
  • [33] Assessing the ventilation effectiveness of naturally ventilated livestock buildings under wind dominated conditions using computational fluid dynamics
    Norton, Tomas
    Grant, Jim
    Fallon, Richard
    Sun, Da-Wen
    BIOSYSTEMS ENGINEERING, 2009, 103 (01) : 78 - 99
  • [34] Mainstream end-tidal carbon dioxide monitoring in ventilated neonates
    Bhat, Y. R.
    Abhishek, N.
    SINGAPORE MEDICAL JOURNAL, 2008, 49 (03) : 199 - 203
  • [35] Monitoring carbon dioxide in mechanically ventilated patients during hyperbaric treatment
    Bjerregard, Asger
    Jansen, Erik
    DIVING AND HYPERBARIC MEDICINE, 2012, 42 (03) : 134 - 136
  • [36] CONDUCTIMETRIC GAS SENSOR FOR CARBON-DIOXIDE
    HIMPLER, HA
    BRAND, SF
    BRAND, MJD
    ANALYTICAL CHEMISTRY, 1978, 50 (12) : 1623 - 1627
  • [37] POTENTIOMETRIC GAS SENSOR FOR CARBON-DIOXIDE
    MOKHALLALATI, AO
    ISTUDOR, A
    VIRTOSU, D
    LUCA, C
    REVUE ROUMAINE DE CHIMIE, 1985, 30 (01) : 31 - 36
  • [38] MONITORING POLLUTION LEVEL AND MICROCLIMATE CONDITIONS IN A NATURALLY VENTILATED LIVESTOCK BUILDING USING OPEN-SOURCE DEVICE
    Denizopoulou, A.
    Karnoutsos, P.
    Martzopoulou, A.
    Giantsis, I.
    Andreopoulou, Z.
    Kotsopoulos, T.
    Fragos, V.
    Nikita-Martzopoulou, Ch.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2019, 20 (01): : 1 - 11
  • [39] INFRARED GAS ANALYZER FOR LOW CONCENTRATIONS OF CARBON DIOXIDE
    WATKINS, JM
    GEMMILL, CL
    ANALYTICAL CHEMISTRY, 1952, 24 (03) : 591 - 591
  • [40] Phase fluorometric optical carbon dioxide gas sensor demonstrated in fermentation off-gas monitoring.
    Sipior, J
    RandersEichhorn, L
    Rao, G
    Carter, GM
    Lakowicz, JR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 197 - BIOT