NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings

被引:55
|
作者
Mendes, Luciano B. [1 ,2 ,3 ]
Ogink, Nico W. M. [2 ]
Edouard, Nadege [4 ]
van Dooren, Hendrik Jan C. [2 ]
Tinoco, Ilda de Fatima F. [3 ]
Mosquera, Julio [2 ]
机构
[1] Inst Agr & Fisheries Res ILVO, Technol & Food Sci Unit T&V, B-9820 Merelbeke, Belgium
[2] Wageningen UR Livestock Res, NL-6700 AC Wageningen, Netherlands
[3] Univ Fed Vicosa, Dept Agr Engn, BR-36570000 Vicosa, MG, Brazil
[4] INRA AgrocampusOuest, PEGASE UMR1348, F-35590 St Gilles, France
来源
SENSORS | 2015年 / 15卷 / 05期
关键词
ventilation rate; CO2 mass balance; dairy barn; open-path laser; photo acoustic spectroscopy; OPEN-PATH FTIR; AMMONIA EMISSIONS; PHOTOACOUSTIC-SPECTROSCOPY; AIR EXCHANGE; LAYING HENS; CO2; DAIRY; BALANCE; HOUSES; VALIDATION;
D O I
10.3390/s150511239
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo-Acoustic Spectroscope (PAS) Gas Monitor and an Open-Path laser (OP-laser). First, calibrations for the NDIR sensors were obtained in the laboratory. Then, the NDIR sensors were placed in a dairy cow barn for comparison with the PAS and OP-laser methods. The main conclusions were: (a) in order to represent the overall barn CO2 concentration of the dairy cow barn, the number of NDIR sensors to be accounted for average concentration calculation was dependent on barn length and on barn area occupation; and (b) the NDIR CO2 sensors are suitable for multi-point monitoring of CO2 concentrations in NV livestock barns, being a feasible alternative for the PAS and the OP-laser methods to monitor single-point or averaged spatial CO2 concentrations in livestock barns.
引用
收藏
页码:11239 / 11257
页数:19
相关论文
共 50 条
  • [21] Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring
    Univ of Maryland at Baltimore, Baltimore, United States
    Biotechnol Prog, 2 (266-271):
  • [22] Monitoring of carbon dioxide in ventilated neonates: a prospective observational study
    Werther, Tobias
    Aichhorn, Lukas
    Stellberg, Sina
    Cardona, Francesco Stefano
    Klebermass-Schrehof, Katrin
    Berger, Angelika
    Schmolzer, Georg M.
    Wagner, Michael
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2022, 107 (03): : 293 - 298
  • [23] EASILY ASSEMBLED AND INEXPENSIVE APPARATUS FOR CONTINUOUS MONITORING OF EXPIRED CARBON-DIOXIDE CONCENTRATIONS IN ARTIFICIALLY VENTILATED ANIMALS
    STRAHLENDORF, HK
    STRAHLENDORF, JC
    JOHNSON, G
    PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1979, 10 (04) : 619 - 621
  • [24] Modelling of ammonia emissions from naturally ventilated livestock buildings. Part 1: Ammonia release modelling
    Bjerg, B.
    Norton, T.
    Banhazi, T.
    Zhang, G.
    Bartzanas, T.
    Liberati, P.
    Cascone, G.
    Lee, I. -B.
    Marucci, A.
    BIOSYSTEMS ENGINEERING, 2013, 116 (03) : 232 - 245
  • [25] Assessments of experimental designs in response surface modelling process: Estimating ventilation rate in naturally ventilated livestock buildings
    Shen, Xiong
    Zhang, Guoqiang
    Bjerg, Bjarne
    ENERGY AND BUILDINGS, 2013, 62 : 570 - 580
  • [26] Application of end-tidal carbon dioxide monitoring via distal gas samples in ventilated neonates
    Jin, Ziying
    Yang, Maoying
    Lin, Ru
    Huang, Wenfang
    Wang, Jiangmei
    Hu, Zhiyong
    Shu, Qiang
    PEDIATRICS AND NEONATOLOGY, 2017, 58 (04): : 370 - 375
  • [27] Ammonia and carbon dioxide concentrations in disposable and reusable ventilated mouse cages
    Silverman, Jerald
    Bays, David W.
    Cooper, Sheldon F.
    Baker, Stephen P.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2008, 47 (02): : 57 - 62
  • [28] Physical and chemical factors influencing the continuous monitoring of carbon monoxide using NDIR sensor
    Kim, Jo-Chun
    Trieu-Vuong Dinh
    Choi, In-Young
    Song, Kyu-Yong
    2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 316 - 319
  • [29] Concentration Gradients of Ammonia, Methane, and Carbon Dioxide at the Outlet of a Naturally Ventilated Dairy Building
    Sahu, Harsh
    Hempel, Sabrina
    Amon, Thomas
    Zentek, Juergen
    Roemer, Anke
    Janke, David
    ATMOSPHERE, 2023, 14 (09)
  • [30] Carbon dioxide/methane gas sensor based on the permselectivity of polymeric membranes for biogas monitoring
    Rego, R
    Mendes, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2) : 2 - 6