Novel 16-Channel Receive Coil Array for Accelerated Upper Airway MRI at 3 Tesla

被引:17
|
作者
Kim, Yoon-Chul [1 ]
Hayes, Cecil E. [2 ]
Narayanan, Shrikanth S. [1 ]
Nayak, Krishna S. [1 ]
机构
[1] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA 90089 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
upper airway MRI; RF coil design; parallel imaging; rapid imaging; OBSTRUCTIVE SLEEP-APNEA; ARBITRARY K-SPACE; RECONSTRUCTION; TRAJECTORIES; SENSE;
D O I
10.1002/mrm.22742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Upper airway MRI can provide a noninvasive assessment of speech and swallowing disorders and sleep apnea. Recent work has demonstrated the value of high-resolution three-dimensional imaging and dynamic two-dimensional imaging and the importance of further improvements in spatio-temporal resolution. The purpose of the study was to describe a novel 16-channel 3 Tesla receive coil that is highly sensitive to the human upper airway and investigate the performance of accelerated upper airway MRI with the coil. In three-dimensional imaging of the upper airway during static posture, 6-fold acceleration is demonstrated using parallel imaging, potentially leading to capturing a whole three-dimensional vocal tract with 1.25 mm isotropic resolution within 9 sec of sustained sound production. Midsagittal spiral parallel imaging of vocal tract dynamics during natural speech production is demonstrated with 2 x 2 mm(2) in-plane spatial and 84 ms temporal resolution. Magn Reson Med 65:1711-1717, 2011. (C)2010 Wiley-Liss, Inc.
引用
收藏
页码:1711 / 1717
页数:7
相关论文
共 50 条
  • [21] A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla
    Adriany, Gregor
    Auerbach, Edward J.
    Snyder, Carl J.
    Gozubuyuk, Ark
    Moeller, Steen
    Ritter, Johannes
    Van de Moortele, Pierre-Francois
    Vaughan, Tommy
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1478 - 1485
  • [22] Evaluation of a 16-Channel Transceiver Loop plus Dipole Antenna Array for Human Head Imaging at 10.5 Tesla
    Woo, Myung Kyun
    Delabarre, Lance
    Lee, Byeong-Yeul
    Waks, Matt
    Lagore, Russell Luke
    Radder, Jerahmie William
    Eryaman, Yigitcan
    Ugurbil, Kamil
    Adriany, Gregor
    IEEE ACCESS, 2020, 8 : 203555 - 203563
  • [23] A 16-Channel Receive, Forced Current Excitation Dual-Transmit Coil for Breast Imaging at 7T
    By, Samantha
    Rispoli, Joseph V.
    Cheshkov, Sergey
    Dimitrov, Ivan
    Cui, Jiaming
    Seiler, Stephen
    Goudreau, Sally
    Malloy, Craig
    Wright, Steven M.
    McDougall, Mary Preston
    PLOS ONE, 2014, 9 (11):
  • [24] 32-Channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry
    Wiggins, G. C.
    Triantafyllou, C.
    Potthast, A.
    Reykowski, A.
    Nittka, M.
    Wald, L. L.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 216 - 223
  • [25] A Six-Channel Pediatric Coil Array for Detection of Children Spinal Pathologies by MRI at 1.5 Tesla
    Lopez Terrones, Marcos Alonso
    Solis-Najera, Sergio Enrique
    XIII MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2014, 1626 : 82 - 85
  • [26] Development and evaluation of a 16-channel receive-only RF coil to improve 7T ultra-high field body MRI with focus on the spine
    Rietsch, Stefan H. G.
    Brunheim, Sascha
    Orzada, Stephan
    Voelker, Maximilian N.
    Maderwald, Stefan
    Bitz, Andreas K.
    Gratz, Marcel
    Ladd, Mark E.
    Quick, Harald H.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 796 - 810
  • [27] 96-Channel Receive-Only Head Coil for 3 Tesla: Design Optimization and Evaluation
    Wiggins, Graham C.
    Polimeni, Jonathan R.
    Potthast, Andreas
    Schmitt, Melanie
    Alagappan, Vijay
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 754 - 762
  • [28] A dedicated eight-channel receive RF coil array for monkey brain MRI at 9.4 T
    Li, Mingyan
    Li, Yu
    Jin, Jin
    Yang, Zhengyi
    Zhang, Baogui
    Liu, Yanyan
    Song, Ming
    Freakly, Craig
    Weber, Ewald
    Liu, Feng
    Jiang, Tianzi
    Crozier, Stuart
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [29] The Design of an Open MRI 4-Channel Receive-Only Phased Array Knee Coil
    Xiaowei He
    Renbo Yuan
    Bing Keong Li
    Yuqing Hou
    Applied Magnetic Resonance, 2016, 47 : 499 - 510
  • [30] Design, evaluation and application of an eight channel transmit/receive coil array for cardiac MRI at 7.0 T
    Graessl, Andreas
    Winter, Lukas
    Thalhammer, Christof
    Renz, Wolfgang
    Kellman, Peter
    Martin, Conrad
    von Knobelsdorff-Brenkenhoff, Florian
    Tkachenko, Valeriy
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 752 - 759