A dedicated eight-channel receive RF coil array for monkey brain MRI at 9.4 T

被引:6
|
作者
Li, Mingyan [1 ]
Li, Yu [1 ]
Jin, Jin [1 ,2 ]
Yang, Zhengyi [1 ,3 ]
Zhang, Baogui [3 ]
Liu, Yanyan [3 ]
Song, Ming [3 ,4 ,5 ]
Freakly, Craig [1 ]
Weber, Ewald [1 ]
Liu, Feng [1 ]
Jiang, Tianzi [3 ,4 ,5 ,6 ,7 ,8 ]
Crozier, Stuart [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Siemens Healthcare Pty Ltd, Bowen Hills, Qld 4006, Australia
[3] Chinese Acad Sci, Brainnetome Ctr, Inst Automat, Beijing, Peoples R China
[4] Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing, Peoples R China
[5] Univ Chinese Acad Sci, Beijing, Peoples R China
[6] Chinese Acad Sci, CAS Ctr Excellence Brain Sci & Intelligence Techn, Inst Automat, Beijing, Peoples R China
[7] Univ Elect Sci & Technol China, Sch Life Sci & Technol, Minist Educ, Key Lab NeuroInformat, Chengdu, Peoples R China
[8] Univ Queensland, Queensland Brain Inst, Brisbane, Qld, Australia
基金
中国国家自然科学基金;
关键词
applications; array coils; computational; electromagnetics; diffusion-weighted imaging; MR engineering; neurological; parallel imaging; NOISE RATIO; FIELD MRI; RESONANCE; DIFFUSION; CORTEX; FMRI; INSIGHTS; TRANSMIT; TRACKING; INJURY;
D O I
10.1002/nbm.4369
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The neuroimaging of nonhuman primates (NHPs) realised with magnetic resonance imaging (MRI) plays an important role in understanding brain structures and functions, as well as neurodegenerative diseases and pathological disorders. Theoretically, an ultrahigh field MRI (>= 7 T) is capable of providing a higher signal-to-noise ratio (SNR) for better resolution; however, the lack of appropriate radiofrequency (RF) coils for 9.4 T monkey MRI undermines the benefits provided by a higher field strength. In particular, the standard volume birdcage coil at 9.4 T generates typical destructive interferences in the periphery of the brain, which reduces the SNR in the neuroscience-focused cortex region. Also, the standard birdcage coil is not capable of performing parallel imaging. Consequently, extended scan durations may cause unnecessary damage due to overlong anaesthesia. In this work, assisted by numerical simulations, an eight-channel receive RF coil array was specially designed and manufactured for imaging NHPs at 9.4 T. The structure and geometry of the proposed receive array was optimised with numerical simulations, so that the SNR enhancement region was particularly focused on monkey brain. Validated with rhesus monkey and cynomolgus monkey brain images acquired from a 9.4 T MRI scanner, the proposed receive array outperformed standard birdcage coil with higher SNR, mean diffusivity and fractional anisotropy values, as well as providing better capability for parallel imaging.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Eight-channel transmit/receive body MRI coil at 3T
    Vernickel, P.
    Roeschmann, P.
    Findeklee, C.
    Luedeke, K.-M.
    Leussler, Ch.
    Overwag, J.
    Katscher, U.
    Graesslin, I.
    Schuenemann, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 381 - 389
  • [2] An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T
    Kraff, Oliver
    Bitz, Andreas K.
    Kruszona, Stefan
    Orzada, Stephan
    Schaefer, Lena C.
    Theysohn, Jens M.
    Maderwald, Stefan
    Ladd, Mark E.
    Quick, Harald H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (11) : 734 - 740
  • [3] An eight-channel sodium/proton coil for brain MRI at 3T
    Lakshmanan, Karthik
    Brown, Ryan
    Madelin, Guillaume
    Qian, Yongxian
    Boada, Fernando
    Wiggins, Graham C.
    NMR IN BIOMEDICINE, 2018, 31 (02)
  • [4] Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging
    Wiggins, GC
    Potthast, A
    Triantafyllou, C
    Wiggins, CJ
    Wald, LL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 235 - 240
  • [5] An eight-channel, nonoverlapping phased array coil with capacitive decoupling for parallel MRI at 3 T
    Von Morze, Cornelius
    Tropp, James
    Banerjee, Suchandrima
    Xu, Duan
    Karpodinis, Kostas
    Carvajal, Lucas
    Hess, Christopher P.
    Mukherjee, Pratik
    Majumdar, Sharmila
    Vigneron, Daniel B.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2007, 31B (01) : 37 - 43
  • [6] A High-Throughput Eight-Channel Probe Head for Murine MRI at 9.4 T
    Lanz, Titus
    Mueller, Matthias
    Barnes, Hannah
    Neubauer, Stefan
    Schneider, Juergen E.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 80 - 87
  • [7] An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T
    Kraff, Oliver
    Bitz, Andreas K.
    Dammann, Philipp
    Ladd, Susanne C.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2010, 37 (12) : 6368 - 6376
  • [8] Eight-Channel Phased Array RF Coils Design for 3T Parallel MRI System
    Basari
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 IEEE 4TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2015, : 56 - 57
  • [9] Field Distribution and Coupling Investigation of an Eight-Channel RF Coil Consisting of Different Dipole Coil Elements for 7 T MRI
    Chen, Zhichao
    Solbach, Klaus
    Erni, Daniel
    Rennings, Andreas
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (06) : 1297 - 1304
  • [10] Design, evaluation and application of an eight channel transmit/receive coil array for cardiac MRI at 7.0 T
    Graessl, Andreas
    Winter, Lukas
    Thalhammer, Christof
    Renz, Wolfgang
    Kellman, Peter
    Martin, Conrad
    von Knobelsdorff-Brenkenhoff, Florian
    Tkachenko, Valeriy
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 752 - 759