A dedicated eight-channel receive RF coil array for monkey brain MRI at 9.4 T

被引:6
|
作者
Li, Mingyan [1 ]
Li, Yu [1 ]
Jin, Jin [1 ,2 ]
Yang, Zhengyi [1 ,3 ]
Zhang, Baogui [3 ]
Liu, Yanyan [3 ]
Song, Ming [3 ,4 ,5 ]
Freakly, Craig [1 ]
Weber, Ewald [1 ]
Liu, Feng [1 ]
Jiang, Tianzi [3 ,4 ,5 ,6 ,7 ,8 ]
Crozier, Stuart [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Siemens Healthcare Pty Ltd, Bowen Hills, Qld 4006, Australia
[3] Chinese Acad Sci, Brainnetome Ctr, Inst Automat, Beijing, Peoples R China
[4] Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing, Peoples R China
[5] Univ Chinese Acad Sci, Beijing, Peoples R China
[6] Chinese Acad Sci, CAS Ctr Excellence Brain Sci & Intelligence Techn, Inst Automat, Beijing, Peoples R China
[7] Univ Elect Sci & Technol China, Sch Life Sci & Technol, Minist Educ, Key Lab NeuroInformat, Chengdu, Peoples R China
[8] Univ Queensland, Queensland Brain Inst, Brisbane, Qld, Australia
基金
中国国家自然科学基金;
关键词
applications; array coils; computational; electromagnetics; diffusion-weighted imaging; MR engineering; neurological; parallel imaging; NOISE RATIO; FIELD MRI; RESONANCE; DIFFUSION; CORTEX; FMRI; INSIGHTS; TRANSMIT; TRACKING; INJURY;
D O I
10.1002/nbm.4369
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The neuroimaging of nonhuman primates (NHPs) realised with magnetic resonance imaging (MRI) plays an important role in understanding brain structures and functions, as well as neurodegenerative diseases and pathological disorders. Theoretically, an ultrahigh field MRI (>= 7 T) is capable of providing a higher signal-to-noise ratio (SNR) for better resolution; however, the lack of appropriate radiofrequency (RF) coils for 9.4 T monkey MRI undermines the benefits provided by a higher field strength. In particular, the standard volume birdcage coil at 9.4 T generates typical destructive interferences in the periphery of the brain, which reduces the SNR in the neuroscience-focused cortex region. Also, the standard birdcage coil is not capable of performing parallel imaging. Consequently, extended scan durations may cause unnecessary damage due to overlong anaesthesia. In this work, assisted by numerical simulations, an eight-channel receive RF coil array was specially designed and manufactured for imaging NHPs at 9.4 T. The structure and geometry of the proposed receive array was optimised with numerical simulations, so that the SNR enhancement region was particularly focused on monkey brain. Validated with rhesus monkey and cynomolgus monkey brain images acquired from a 9.4 T MRI scanner, the proposed receive array outperformed standard birdcage coil with higher SNR, mean diffusivity and fractional anisotropy values, as well as providing better capability for parallel imaging.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers
    Moody, Katherine Lynn
    Hollingsworth, Neal A.
    Zhao, Feng
    Nielsen, Jon-Fredrik
    Noll, Douglas C.
    Wright, Steven M.
    McDougall, Mary Preston
    JOURNAL OF MAGNETIC RESONANCE, 2014, 246 : 62 - 68
  • [32] Optimization of a quadrature birdcage coil for functional imaging of squirrel monkey brain at 9.4T
    Lu, Ming
    Yang, Zhangyan
    Wang, Feng
    Drake, Gary
    Chen, Li Min
    Gore, John C.
    Yan, Xinqiang
    MAGNETIC RESONANCE IMAGING, 2021, 79 : 45 - 51
  • [33] Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging
    Brown, Ryan
    Madelin, Guillaume
    Lattanzi, Riccardo
    Chang, Gregory
    Regatte, Ravinder R.
    Sodickson, Daniel K.
    Wiggins, Graham C.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 259 - 268
  • [34] A 48-channel receive array coil for mesoscopic diffusion-weighted MRI of ex vivo human brain on the 3 T connectome scanner
    Scholz, Alina
    Etzel, Robin
    May, Markus W.
    Mahmutovic, Mirsad
    Tian, Qiyuan
    Ramos-Llorden, Gabriel
    Maffei, Chiara
    Bilgic, Berkin
    Witzel, Thomas
    Stockmann, Jason P.
    Mekkaoui, Choukri
    Wald, Lawrence L.
    Huang, Susie Yi
    Yendiki, Anastasia
    Keil, Boris
    NEUROIMAGE, 2021, 238
  • [35] A 16-Channel Dual-Row Transmit Array in Combination with a 31-Element Receive Array for Human Brain Imaging at 9.4 T
    Shajan, G.
    Kozlov, Mikhail
    Hoffmann, Jens
    Turner, Robert
    Scheffler, Klaus
    Pohmann, Rolf
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 870 - 879
  • [36] Design Decoupling Methods of Multichannel Phased Array Receive Only RF Coil for Different Structures of 1.5T MRI
    Dapkar, Radhika
    Ugle, Niket
    Bagchi, Soumendu
    Bhuiya, Tapas
    Kulkarni, A. M.
    Gaikwad, Sandeep
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, : 606 - 610
  • [37] Design and construction of an 8-channel transceiver coil array for rat imaging at 9.4 T
    Du, Feng
    Li, Nan
    Yang, Xing
    Zhang, Baogui
    Zhang, Xiaoliang
    Li, Ye
    JOURNAL OF MAGNETIC RESONANCE, 2023, 351
  • [38] Size-Adaptive Occipital 18-Channel Receive-Only RF Coil for 3T MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024,
  • [39] Quadrature RF coil for in Vivo brain MRI of a macaque monkey in a stereotaxic head frame
    Roopnariane, Colin A.
    Ryu, Yeun-Chul
    Tofighi, Mohammad-Reza
    Miller, Patti A.
    Oh, Sukhoon
    Wang, Jianli
    Park, Bu Sik
    Ansel, Lukas
    Lieu, Christopher A.
    Subramanian, Thyagarajan
    Yang, Qing X.
    Collins, Christopher M.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2012, 41B (01) : 22 - 27
  • [40] 3D 1H MRSI of brain tumors at 3.0 tesla using an eight-channel phased-array head coil
    Osorio, Joseph A.
    Ozturk-Isik, Esin
    Xu, Duan
    Cha, Soonmee
    Chang, Susan
    Berger, Mitchel S.
    Vigneron, Daniel B.
    Nelson, Sarah J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) : 23 - 30