32-Channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry

被引:322
|
作者
Wiggins, G. C.
Triantafyllou, C.
Potthast, A.
Reykowski, A.
Nittka, M.
Wald, L. L.
机构
[1] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Dept Radiol, Boston, MA 02129 USA
[2] Siemens Med Solut, Erlangen, Germany
[3] Invivo Corp, Gainesville, FL USA
关键词
phased array; 32-channel; RF coil design; SNR; g-factor;
D O I
10.1002/mrm.20925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 32-channel 3T receive-only phased-array head coil was developed for human brain imaging. The helmet-shaped array was designed to closely fit the head with individual overlapping circular elements arranged in patterns of hexagonal and pentagonal symmetry similar to that of a soccer ball. The signal-to-noise ratio (SNR) and noise amplification (g-factor) in accelerated imaging applications were quantitatively evaluated in phantom and human images and compared with commercially available head coils. The 32-channel coil showed SNR gains of up to 3.5-fold in the cortex and 1.4-fold in the corpus callosum compared to a (larger) commercial eight-channel head coil. The experimentally measured g-factor performance of the helmet array showed significant improvement compared to the eight-channel array (peak g-factor 59% and 26% of the eight-channel values for four- and fivefold acceleration). The performance of the arrays is demonstrated in high-resolution and highly accelerated brain images.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 33 条
  • [1] 96-Channel Receive-Only Head Coil for 3 Tesla: Design Optimization and Evaluation
    Wiggins, Graham C.
    Polimeni, Jonathan R.
    Potthast, Andreas
    Schmitt, Melanie
    Alagappan, Vijay
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 754 - 762
  • [2] Customized Radiofrequency Phased-Array Coil Combining Transmit-Only, Receive-Only, and Transmit/Receive Coils for Magnetic Resonance Imaging of Visual Cortex at 7 Tesla
    Kim, Hyeong-Seop
    Song, Byung-Pan
    Kim, Royoung
    Choi, Woo-Chul
    Kim, Donghyuk
    Shim, Won Mok
    Kim, Kyoung-Nam
    Lee, Seung-Kyun
    IEEE ACCESS, 2022, 10 : 42083 - 42093
  • [3] A New Phased-Array Magnetic Resonance Imaging Receive-Only Coil for HBO2 Studies
    Mareyam, Azma
    Shank, Erik
    Wald, Lawrence L.
    Qin, Michael K.
    Bonmassar, Giorgio
    SENSORS, 2022, 22 (16)
  • [4] 32-channel phased-array receive with asymmetric birdcage transmit coil for hyperpolarized xenon-129 lung imaging
    Dregely, Isabel
    Ruset, Iulian C.
    Wiggins, Graham
    Mareyam, Azma
    Mugler, John P., III
    Altes, Talissa A.
    Meyer, Craig
    Ruppert, Kai
    Wald, Lawrence L.
    Hersman, F. William
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 576 - 583
  • [5] The Design of an Open MRI 4-Channel Receive-Only Phased Array Knee Coil
    Xiaowei He
    Renbo Yuan
    Bing Keong Li
    Yuqing Hou
    Applied Magnetic Resonance, 2016, 47 : 499 - 510
  • [6] The Design of an Open MRI 4-Channel Receive-Only Phased Array Knee Coil
    He, Xiaowei
    Yuan, Renbo
    Li, Bing Keong
    Hou, Yuqing
    APPLIED MAGNETIC RESONANCE, 2016, 47 (05) : 499 - 510
  • [7] Design and Evaluation of a 32-Channel Phased-Array Coil for Lung Imaging with Hyperpolarized 3-Helium
    Meise, Florian M.
    Rivoire, Julien
    Terekhov, Maxim
    Wiggins, Graham C.
    Keil, Boris
    Karpuk, Sergej
    Salhi, Zahir
    Wald, Lawrence L.
    Schreiber, Laura M.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 456 - 464
  • [8] Automated Tuning and Matching of a 16-Channel TEM Transmit-Only Array used in Conjunction with a 32-Channel Receive-Only Loop Array for MR Cardiac Imaging at 7 Tesla.
    Snyder, Carl J.
    DelaBarre, Lance
    Vaughan, J. Thomas
    2013 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (IMS), 2013,
  • [9] Sodium-23 MRI of whole spine at 3 Tesla using a 5-channel receive-only phased-array and a whole-body transmit resonator
    Malzacher, Matthias
    Kalayciyan, Raffi
    Konstandin, Simon
    Haneder, Stefan
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 95 - 100
  • [10] A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 tesla
    Schmitt, Melanie
    Potthast, Andreas
    Sosnovik, David E.
    Polimeni, Jonathan R.
    Wiggins, Graham C.
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1431 - 1439