Automated Tuning and Matching of a 16-Channel TEM Transmit-Only Array used in Conjunction with a 32-Channel Receive-Only Loop Array for MR Cardiac Imaging at 7 Tesla.

被引:0
|
作者
Snyder, Carl J. [1 ]
DelaBarre, Lance [1 ]
Vaughan, J. Thomas [1 ]
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55408 USA
关键词
Impedance matching; Magnetic resonance imaging; Microstrip arrays; Piezoelectric actuation; 7; tesla;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radiofrequency (RF) coils are antenna-like devices used in magnetic resonance imaging (MRI) to inductively excite and receive the nuclear magnetic resonance (NMR) signal in anatomy. Recently, coil arrays have shown significant advantages over large single channel volume coils at ultra-high magnetic field strengths. However, to maximize the full potential, each individual coil within the array needs to be "tuned and matched" to the anatomy (load) prior to imaging. Tuning and matching can be a tedious and time consuming process, and has been cited as a problem that precludes ultra-high field strength MRI from a becoming a clinical reality. Here, we have developed an electromechanical solution. A 16-channel transmit-only TEM array was designed and fitted with piezoelectric actuators mechanically linked to sliding cylindrical tuning and matching capacitors to automate the tuning and matching process, based on the coil's reflection coefficient.
引用
收藏
页数:4
相关论文
共 10 条
  • [1] Customized Radiofrequency Phased-Array Coil Combining Transmit-Only, Receive-Only, and Transmit/Receive Coils for Magnetic Resonance Imaging of Visual Cortex at 7 Tesla
    Kim, Hyeong-Seop
    Song, Byung-Pan
    Kim, Royoung
    Choi, Woo-Chul
    Kim, Donghyuk
    Shim, Won Mok
    Kim, Kyoung-Nam
    Lee, Seung-Kyun
    IEEE ACCESS, 2022, 10 : 42083 - 42093
  • [2] Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla
    de Zwart, JA
    Ledden, PJ
    van Gelderen, P
    Bodurka, J
    Chu, RX
    Duyn, JH
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 22 - 26
  • [3] A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla
    Adriany, Gregor
    Auerbach, Edward J.
    Snyder, Carl J.
    Gozubuyuk, Ark
    Moeller, Steen
    Ritter, Johannes
    Van de Moortele, Pierre-Francois
    Vaughan, Tommy
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1478 - 1485
  • [4] 32-Channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry
    Wiggins, G. C.
    Triantafyllou, C.
    Potthast, A.
    Reykowski, A.
    Nittka, M.
    Wald, L. L.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 216 - 223
  • [5] A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla
    Adriany, Gregor
    De Moortele, Pierre-Francois Van
    Ritter, Johannes
    Moeller, Steen
    Auerbach, Edward J.
    Akguen, Can
    Snyder, Carl J.
    Vaughan, Thomas
    Ugurbill, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 590 - 597
  • [6] 7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array
    Rietsch, Stefan H. G.
    Orzada, Stephan
    Maderwald, Stefan
    Brunheim, Sascha
    Philips, Bart W. J.
    Scheenen, Tom W. J.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2018, 45 (07) : 2978 - 2990
  • [7] A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla
    May, Markus W.
    Hansen, Sam-Luca J. D.
    Mahmutovic, Mirsad
    Scholz, Alina
    Kutscha, Nicolas
    Guerin, Bastien
    Stockmann, Jason P.
    Barry, Robert L.
    Kazemivalipour, Ehsan
    Gumbrecht, Rene
    Kimmlingen, Ralph
    Adriany, Markus
    Chang, Yulin
    Triantafyllou, Christina
    Knake, Susanne
    Wald, Lawrence L.
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (03) : 1419 - 1433
  • [8] A combined 32-channel receive-loops/8-channel transmit-dipoles coil array for whole-brain MR imaging at 7T
    Clement, Jeremie
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1229 - 1241
  • [9] Sodium-23 MRI of whole spine at 3 Tesla using a 5-channel receive-only phased-array and a whole-body transmit resonator
    Malzacher, Matthias
    Kalayciyan, Raffi
    Konstandin, Simon
    Haneder, Stefan
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 95 - 100
  • [10] In vivo phosphorus magnetic resonance spectroscopic imaging of the whole human liver at 7 T using a phosphorus whole-body transmit coil and 16-channel receive array: Repeatability and effects of principal component analysis-based denoising
    van den Wildenberg, Lieke
    Gursan, Ayhan
    Seelen, Leonard W. F.
    van der Velden, Tijl A.
    Gosselink, Mark W. J. M.
    Froeling, Martijn
    van der Kemp, Wybe J. M.
    Klomp, Dennis W. J.
    Prompers, Jeanine J.
    NMR IN BIOMEDICINE, 2023, 36 (05)