Novel 16-Channel Receive Coil Array for Accelerated Upper Airway MRI at 3 Tesla

被引:17
|
作者
Kim, Yoon-Chul [1 ]
Hayes, Cecil E. [2 ]
Narayanan, Shrikanth S. [1 ]
Nayak, Krishna S. [1 ]
机构
[1] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA 90089 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
upper airway MRI; RF coil design; parallel imaging; rapid imaging; OBSTRUCTIVE SLEEP-APNEA; ARBITRARY K-SPACE; RECONSTRUCTION; TRAJECTORIES; SENSE;
D O I
10.1002/mrm.22742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Upper airway MRI can provide a noninvasive assessment of speech and swallowing disorders and sleep apnea. Recent work has demonstrated the value of high-resolution three-dimensional imaging and dynamic two-dimensional imaging and the importance of further improvements in spatio-temporal resolution. The purpose of the study was to describe a novel 16-channel 3 Tesla receive coil that is highly sensitive to the human upper airway and investigate the performance of accelerated upper airway MRI with the coil. In three-dimensional imaging of the upper airway during static posture, 6-fold acceleration is demonstrated using parallel imaging, potentially leading to capturing a whole three-dimensional vocal tract with 1.25 mm isotropic resolution within 9 sec of sustained sound production. Midsagittal spiral parallel imaging of vocal tract dynamics during natural speech production is demonstrated with 2 x 2 mm(2) in-plane spatial and 84 ms temporal resolution. Magn Reson Med 65:1711-1717, 2011. (C)2010 Wiley-Liss, Inc.
引用
收藏
页码:1711 / 1717
页数:7
相关论文
共 50 条
  • [11] 16-Channel Bow Tie Antenna Transceiver Array for Cardiac MR at 7.0 Tesla
    Oezerdem, Celal
    Winter, Lukas
    Graessl, Andreas
    Paul, Katharina
    Els, Antje
    Weinberger, Oliver
    Rieger, Jan
    Kuehne, Andre
    Dieringer, Matthias
    Hezel, Fabian
    Voit, Dirk
    Frahm, Jens
    Niendorf, Thoralf
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) : 2553 - 2565
  • [12] An Open Source 16-Channel Breast Array for Prone and Supine MRI
    Narongrit, Folk W.
    Ramesh, Thejas Vishnu
    Rispoli, Joseph V.
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024, 8 (03): : 251 - 258
  • [13] A 64-channel 3T array coil for accelerated brain MRI
    Keil, Boris
    Blau, James N.
    Biber, Stephan
    Hoecht, Philipp
    Tountcheva, Veneta
    Setsompop, Kawin
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 248 - 258
  • [14] A 16-Channel Dipole Antenna Array for Human Head Magnetic Resonance Imaging at 10.5 Tesla
    Woo, Myung Kyun
    DelaBarre, Lance
    Waks, Matt
    Radder, Jerahmie
    Choi, Uk-Su
    Lagore, Russell
    Ugurbil, Kamil
    Adriany, Gregor
    SENSORS, 2021, 21 (21)
  • [15] A 22-channel receive array with Helmholtz transmit coil for anesthetized macaque MRI at 3 T
    Janssens, Thomas
    Keil, Boris
    Serano, Peter
    Mareyam, Azma
    McNab, Jennifer A.
    Wald, Lawrence L.
    Vanduffel, Wim
    NMR IN BIOMEDICINE, 2013, 26 (11) : 1431 - 1440
  • [16] Increased Vessel Depiction of the Carotid Bifurcation with a Specialized 16-Channel Phased Array Coil at 3T
    Tate, Quinn
    Kim, Seong-Eun
    Treiman, Gerald
    Parker, Dennis L.
    Hadley, J. Rock
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1486 - 1493
  • [17] A size-adaptive 32-channel array coil for awake infant neuroimaging at 3 Tesla MRI
    Ghotra, Anpreet
    Kosakowski, Heather L.
    Takahashi, Atsushi
    Etzel, Robin
    May, Markus W.
    Scholz, Alina
    Jansen, Andreas
    Wald, Lawrence L.
    Kanwisher, Nancy
    Saxe, Rebecca
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1773 - 1785
  • [18] A 20-Channel Receive-Only Mouse Array Coil for a 3 T Clinical MRI System
    Keil, Boris
    Wiggins, Graham C.
    Triantafyllou, Christina
    Wald, Lawrence L.
    Meise, Florian M.
    Schreiber, Laura M.
    Klose, Klaus J.
    Heverhagen, Johannes T.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 584 - 595
  • [19] Comparison of 16-Channel Asymmetric Sleeve Antenna and Dipole Antenna Transceiver Arrays at 10.5 Tesla MRI
    Woo, Myung Kyun
    Dela Barre, Lance
    Waks, Matt
    Lee, Jingu
    Lagore, Russell Luke
    Jungst, Steve
    Grant, Andrea
    Eryaman, Yigitcan
    Ugurbil, Kamil
    Adriany, Gregor
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (04) : 1147 - 1156
  • [20] Automated Tuning and Matching of a 16-Channel TEM Transmit-Only Array used in Conjunction with a 32-Channel Receive-Only Loop Array for MR Cardiac Imaging at 7 Tesla.
    Snyder, Carl J.
    DelaBarre, Lance
    Vaughan, J. Thomas
    2013 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (IMS), 2013,