Effect of abutment finish lines on the mechanical behavior and marginal fit of screw-retained implant crowns: An in vitro study

被引:0
|
作者
Garcia-Gonzalez, Marta
Gonzalez-Gonzalez, Ignacio [1 ]
Garcia-Garcia, Ismael [2 ]
Blason-Gonzalez, Sergio [3 ]
Lamela-Rey, Maria Jesus [2 ]
Fernandez-Canteli, Alfonso [2 ]
Alvarez-Arenal, Angel [1 ]
机构
[1] Univ Oviedo, Sch Dent, Dept Prosthodont & Occlus, Catedrat Serrano S-N, Oviedo 33006, Spain
[2] Univ Oviedo, Dept Construct & Mfg Engn, Campus Viesques, Gijon, Spain
[3] Bundesanstalt Materialforsch & Prufung BAM, Dept Component Safety, Berlin, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 127卷 / 02期
关键词
FRACTURE; CAD/CAM; SYSTEM; MISFIT;
D O I
10.1016/j.prosdent.2021.08.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The design of the implant-abutment connection has been widely researched, but the impact of different crown-abutment geometries remains unclear. Purpose. The purpose of this in vitro study was to evaluate the effect of different crown-abutment margin geometries on the mechanical behavior and fit of screw-retained implant-supported single-crown restorations by using mechanical static and fatigue tests and mastication simulation. Material and methods. A total of 45 cobalt-chromium premolar-shaped metal frameworks were fabricated for single-unit implant-supported screw-retained restorations on stock abutments and internal hexagon empty set4.25x11-mm cylindrical implants. They were divided into 3 groups according to margin geometry: S, shoulder; C, chamfer; and F, feather-edge. Three static load until fracture and 24 dynamic load tests were performed by using the International Organization for Standardization 14801:2016 standard (ISO 14801:2016) (number of cycles limit: 5x10(6) cycles, frequency: 6 Hz). The ProFatigue software program was used to optimize the procedure (S, n=12 specimens; C, n=7 specimens; and F, n=5 specimens). Six additional specimens from each group were subjected to a mastication simulation (limit number of cycles: 1x10(6) cycles, cyclic loading from P-min=30 N to P-max=300 N, frequency: 6 Hz). Results from the fatigue tests were reported descriptively, and the Fisher exact test was used to analyze the difference in failure modes. Data from maximum misfit were evaluated by photogrammetry and statistically analyzed with the Anderson-Darling test and the Kruskal-Wallis and Dunn multiple comparison tests (alpha=.05). Results. The fatigue limit was 456 N for group S, 512 N for group C, and 514 N for group F. The mean +/- standard deviation misfit was 2.6 +/- 0.1 mu m for group S, 3.8 +/- 1.1 mu m for group C, and 3.6 +/- 0.8 mu m for group F. Differences in misfit between groups S and C and between groups S and F were statistically significant (P<.05). Conclusions. Crown-abutment connections with chamfer and feather-edge margins showed better mechanical behavior, while shoulder margin exhibited better fit. However, high levels of fit were achieved for all the evaluated geometries.
引用
收藏
页码:318.e1 / 318.e10
页数:10
相关论文
共 50 条
  • [1] Marginal fit of cemented and screw-retained crowns incorporated on the Straumann (ITI)® Dental Implant System: an in vitro study
    Tosches, N. A.
    Braegger, U.
    Lang, N. P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (01) : 79 - 86
  • [2] The influence of the restorative material on the mechanical behavior of screw-retained hybrid-abutment-crowns
    Yazigi, Christine
    Kern, Matthias
    Chaar, Mohamed Sad
    Libecki, Wojtek
    Elsayed, Adham
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 111 (111)
  • [3] Marginal fit of cemented and screw-retained crowns incorporated onto the ITI® Dental Implant System.
    Brägger, U
    Tosches, N
    Flury, K
    Lang, NP
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 901 - 901
  • [4] Prevention of bacterial leakage into screw-retained implant crowns in vitro
    Guindy, JS
    Besimo, CE
    Besimo, R
    Lewetag, D
    Meyer, J
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 122 - 122
  • [5] Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implant abutments
    Keith, SE
    Miller, BH
    Woody, RD
    Higginbottom, FL
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (03) : 369 - 378
  • [6] Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
    Rico-Coderch, Aitana
    Felix, Luis F.
    Sola-Ruiz, Maria Fernanda
    Medina, Michell
    Agustin-Panadero, Ruben
    Ortega, Rocio
    Cascos, Rocio
    Gomez-Polo, Miguel
    METALS, 2024, 14 (07)
  • [7] Mechanical Behavior and Fracture Loads of Screw-Retained and Cement-Retained Lithium Disilicate Implant-Supported Crowns
    Camatta, Hercules Pessin
    Ferreira, Rodrigo Melim
    Ferrairo, Brunna Mota
    Strelhow, Samira Sandy
    Rubo, Jose Henrique
    Mori, Aline Akemi
    Ferruzzi, Fernanda
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (08): : 690 - 697
  • [8] Original vs. non-original abutments for screw-retained single implant crowns: An in vitro evaluation of internal fit, mechanical behaviour and screw loosening
    Alonso-Perez, Raquel
    Bartolome, Jose F.
    Ferreiroa, Alberto
    Salido, Maria P.
    Pradies, Guillermo
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1230 - 1238
  • [9] Mechanical Stability of Screw-Retained Monolithic and Bi-Layer Posterior Hybrid Abutment Crowns after Thermomechanical Loading: An In Vitro Study
    Spitznagel, Frank A.
    Bonfante, Estevam A.
    Campos, Tiago M. B.
    Vollmer, Maximilian A.
    Boldt, Johannes
    Doerken, Sam
    Gierthmuehlen, Petra C.
    MATERIALS, 2021, 14 (24)
  • [10] Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections
    Ugurel, Cihan Sadi
    Steiner, Martin
    Isik-Ozkol, Gul
    Kutay, Omer
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 137 - 142