Implant Impression Techniques using Different Materials and Methods: A Review

被引:2
|
作者
Yasar, Muhammed Necati [1 ]
Cetinsahin, Cem [1 ]
Bayar, Omer [1 ]
Ozer, Hasan Yildrim [1 ]
机构
[1] Baskent Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Conventional impression; Custom tray; Digital dentistry; Intraoral digital impression; Slicone elastomers; EDENTULOUS PATIENTS; IN-VITRO; ACCURACY; ANGULATION; PROSTHESES; TIME; FIT;
D O I
10.7860/JCDR/2022/53057.16014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dental implants have emerged as the treatment of choice in for restoring missing teeth in situations that require functional and aesthetic replacements. Reproduction of the position and orientation of intraoral implants by means of an accurate impression in the definitive cast is the first step in achieving a passively fitting multi-implant supported prosthesis, to decrease the mechanical and biological complication of the prosthesis. The accuracy of the impression making procedure in the usage of osseointegrated implants used for the rehabilitation of fully and partially edentulous patients is a very important factor for the long-term success of dental implants. It has been reported that the precision of implant impressions is affected by various factors such as impression materials, impression technique, splinting of impression posts, impression level and depth, as well as the angle of the implants. Also, the incompatibility between implant and prosthesis, which may occur as a result of an incorrect impression, may cause problems such as screw loosening, screw fracture, loss of osseointegration and even implant fracture. Today, there are many articles and reviews about implant impressions. Although the authors found consistent results in many studies, there are differences of opinion on some issues. In general, polyether and additional type silicones were found to be successful in the conventional impression technique. Digital impression technique, on the other hand, has been found as successful as conventional measurement techniques in some studies. Controversial results have been obtained about the number of implants and their angulation. In general, the direct open tray splinted impression method is recommended for four or more implants, while there was no difference between the direct or indirect method for three or less implants.
引用
收藏
页码:ZE12 / ZE17
页数:6
相关论文
共 50 条
  • [31] Evaluation of Accuracy of Casts of Multiple Internal Connection Implant Prosthesis Obtained From Different Impression Materials and Techniques: An In Vitro Study
    Pujari, Malesh
    Garg, Pooja
    Prithviraj, D. R.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (02) : 137 - 145
  • [32] Implant cast accuracy as a function of impression techniques and impression material viscosity
    Walker, Mary P.
    Ries, Dave
    Borello, Blake
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (04) : 669 - 674
  • [33] RETENTION STRENGTH OF IMPRESSION MATERIALS TO A TRAY MATERIAL USING DIFFERENT ADHESIVE METHODS: AN IN VITRO STUDY
    Marafie, Yousef
    Looney, Stephen
    Nelson, Steven
    Chan, Daniel
    Browning, William
    Rueggeberg, Frederick
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06): : 432 - 440
  • [34] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    JOURNAL OF DENTISTRY, 2022, 126
  • [35] Protein isolation techniques of beans using different methods: A review
    Kusumah, S. H.
    Andoyo, R.
    Rialita, T.
    INTERNATIONAL CONFERENCE ON FOOD AND BIO-INDUSTRY 2019, 2020, 443
  • [36] Accuracy of various impression materials and methods for two implant systems: An effect size study
    Schmidt, Alexander
    Haeussling, Teresa
    Rehmann, Peter
    Schaaf, Heidrun
    Woestmann, Bernd
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) : 245 - 251
  • [37] Comparing closed tray implant impression techniques using snap-on and impression analogues on a clinical radiographic scale
    Yuvashree C.S.
    Venugopalan S.
    Nesappan T.
    Delphine Priscilla Antony S.
    Journal of Long-Term Effects of Medical Implants, 2021, 31 (01) : 1 - 6
  • [38] Accuracy of Definitive Casts Using 4 Implant-Level Impression Techniques in a Scenario of Multi-Implant System With Different Implant Angulations and Subgingival Alignment Levels
    Martinez-Rus, Francisco
    Garcia, Carmen
    Santamaria, Andrea
    Ozcan, Mutlu
    Pradies, Guillermo
    IMPLANT DENTISTRY, 2013, 22 (03) : 268 - 276
  • [39] Accuracy of Selective Laser Melted Bar Retaining Mandibular Implant-Assisted Overdenture: An In Vitro Comparison of Different Impression Materials and Techniques
    El-Asfahani, Iman A.
    Ramdan, Amr S.
    Agamy, Emad M. T. M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (06) : 590 - 598
  • [40] The Effect of Splint Material Rigidity in Implant Impression Techniques
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Castanharo, Sabrina Maria
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1153 - 1158