Implant Impression Techniques using Different Materials and Methods: A Review

被引:2
|
作者
Yasar, Muhammed Necati [1 ]
Cetinsahin, Cem [1 ]
Bayar, Omer [1 ]
Ozer, Hasan Yildrim [1 ]
机构
[1] Baskent Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Conventional impression; Custom tray; Digital dentistry; Intraoral digital impression; Slicone elastomers; EDENTULOUS PATIENTS; IN-VITRO; ACCURACY; ANGULATION; PROSTHESES; TIME; FIT;
D O I
10.7860/JCDR/2022/53057.16014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dental implants have emerged as the treatment of choice in for restoring missing teeth in situations that require functional and aesthetic replacements. Reproduction of the position and orientation of intraoral implants by means of an accurate impression in the definitive cast is the first step in achieving a passively fitting multi-implant supported prosthesis, to decrease the mechanical and biological complication of the prosthesis. The accuracy of the impression making procedure in the usage of osseointegrated implants used for the rehabilitation of fully and partially edentulous patients is a very important factor for the long-term success of dental implants. It has been reported that the precision of implant impressions is affected by various factors such as impression materials, impression technique, splinting of impression posts, impression level and depth, as well as the angle of the implants. Also, the incompatibility between implant and prosthesis, which may occur as a result of an incorrect impression, may cause problems such as screw loosening, screw fracture, loss of osseointegration and even implant fracture. Today, there are many articles and reviews about implant impressions. Although the authors found consistent results in many studies, there are differences of opinion on some issues. In general, polyether and additional type silicones were found to be successful in the conventional impression technique. Digital impression technique, on the other hand, has been found as successful as conventional measurement techniques in some studies. Controversial results have been obtained about the number of implants and their angulation. In general, the direct open tray splinted impression method is recommended for four or more implants, while there was no difference between the direct or indirect method for three or less implants.
引用
收藏
页码:ZE12 / ZE17
页数:6
相关论文
共 50 条
  • [21] A comparison of mandibular denture base deformation with different impression techniques for implant overdentures
    Elsyad, Moustafa Abdou
    El-Waseef, Fatma Ahmad
    Al-Mahdy, Yasmeen Fathy
    Fouad, Mohammed Mohammed
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 : 127 - 133
  • [22] Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept
    Liu, David Yu
    Cader, Fathima Nashmie
    Abduo, Jaafar
    Palamara, Joseph
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E682 - E687
  • [23] Accuracy of different impression techniques for multiunit implant restoration: A qualitative in vitro study
    Ismail, Ibrahim Ahmed
    Alhajj, Mohammed Nasser
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : E1 - E5
  • [24] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Elshenawy, Enas A.
    Alam-Eldein, Ahmed M.
    Abd Elfatah, Fadel A.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [25] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Enas A. Elshenawy
    Ahmed M. Alam-Eldein
    Fadel A. Abd Elfatah
    International Journal of Implant Dentistry, 4
  • [26] Study of the fit of 3 implant frameworks using two impression techniques
    Pradies, G
    Bordel, F
    Castillo, F
    del Rio, L
    Suarez, MJ
    del Rio, F
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1245 - 1245
  • [27] QUALITY OF STONE DIES PRODUCED BY DIFFERENT IMPRESSION MATERIALS - A COMPARATIVE-STUDY OF IMPRESSION TECHNIQUES
    WIKTORSSON, G
    FEDER, D
    SWEDISH DENTAL JOURNAL, 1983, 7 (02) : 77 - 83
  • [28] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 (06) : 412 - 415
  • [29] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S412 - S415
  • [30] The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis
    Fluegge, Tabea
    van der Meer, Wicher Joerd
    Gonzalez, Beatriz Gimenez
    Vach, Kirstin
    Wismeijer, Daniel
    Wang, Ping
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 374 - 392