Implant cast accuracy as a function of impression techniques and impression material viscosity

被引:0
|
作者
Walker, Mary P. [1 ,2 ]
Ries, Dave
Borello, Blake
机构
[1] Univ Missouri, Sch Dent, Dept Restorat Dent, Kansas City, MO 64108 USA
[2] Univ Missouri, Sch Dent, Dept Oral Biol, Kansas City, MO 64108 USA
关键词
closed tray direct impressions; closed tray indirect impressions; dental implants;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare implant cast accuracy as a function of impression technique, closed tray impressions using indirect, metal impression copings at the implant level or direct, plastic impression caps at the abutment level, and impression material viscosity combinations. Materials and Methods: A stainless steel master model with three implant replicas was utilized to produce Type IV stone casts. Master model impressions were made using closed trays at the implant level with screw-on metal impression copings (indirect/implant level) or at the abutment level with snap-on plastic impression caps (direct/abutment level). With both techniques, either medium-body or heavy-body polyether impression material was syringed around the implant impression coping or abutment impression cap with medium body material in a custom trays Twenty casts were produced with 5 casts in each test group. A measuring microscope (0.001 mm accuracy) was used to measure cast inter-implant or inter-abutment distances. Cast accuracy was calculated based on the percent difference of the measurements as compared to the master model. Results: A repeated measures 2-factor ANOVA (alpha =.05) indicated no significant difference in cast accuracy as a function of impression viscosity. However, cast accuracy was significantly different between casts made with indirect/implant level versus direct/abutment level impressions. With the plastic impression caps, the cast inter-abutment distances were larger than the master model, with mean percent differences of 0.19% to 0.24% across the 3 measurement sites. In contrast, with the metal impression coping impressions, the cast inter-implant distances were almost equal to or slightly smaller than the master model, with mean percent differences -0.06% to 0.02%. Conclusions: Impression material viscosity does not appear to be a critical factor for implant cast accuracy. However, casts made with indirect, metal impression copings might be more accurate than casts made with direct, plastic impression caps. This could be an especially important factor with casts used to fabricate multiple-implant restorations.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 50 条
  • [1] Effects of Implant System, Impression Technique, and Impression Material on Accuracy of the Working Cast
    Wegner, Kerstin
    Weskott, Katharina
    Zenginel, Martha
    Rehmann, Peter
    Woestmann, Bernd
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (04) : 989 - 995
  • [2] The Influence of Impression Material on the Accuracy of the Master Cast in Implant Restorations
    Stefos, Spyridon
    Kourtis, Stefanos
    Sarafianou, Aspasia
    Zoidis, Panagiotis
    [J]. OPEN DENTISTRY JOURNAL, 2018, 12 : 1123 - 1136
  • [3] Accuracy of implant impression splinted techniques: Effect of splinting material
    Assif, D
    Nissan, J
    Varsano, I
    Singer, A
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (06) : 885 - 888
  • [4] ACCURACY OF IMPRESSION TECHNIQUES IN IMPLANT DENTISTRY
    Alrumi, Bader Abdullah
    al Yami, Ibrahim Mohammed
    Alghamdi, Randah Abdulrhman
    Aldajani, Ali Mohammed
    Alhelaly, Hussein Mohammed
    Mohammed, Abdulrahman Thabet
    Abotaleb, Mohannd Talebalrahman
    Aljuaid, Mohammed Mbearak
    Alotaibi, Jamal Mousa
    Alelyani, Mohammed Dakhil
    [J]. INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (01): : 1396 - 1402
  • [5] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [6] Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy u An in vitro study
    Arora, Aman
    Upadhyaya, Viram
    Parashar, Kirti R.
    Malik, Divya
    [J]. JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (02): : 149 - 158
  • [7] Comparative Evaluation of the Effects of Implant Position, Impression Material, and Tray Type on Implant Impression Accuracy
    Gokcen-Rohlig, Bilge
    Ongul, Deger
    Sancakli, Erkan
    Sermet, Bulent
    [J]. IMPLANT DENTISTRY, 2014, 23 (03) : 283 - 288
  • [8] Effect of Splinting in Accuracy of Two Implant Impression Techniques
    de Avila, Erica Dorigatti
    Moraes, Fernanda de Matos
    Castanharo, Sabrina Maria
    Del'Acqua, Marcelo Antonialli
    Mollo, Francisco de Assis, Jr.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 633 - 639
  • [9] Accuracy of Impression Techniques for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 715 - 721
  • [10] Accuracy Comparison of Implant Impression Techniques: A Systematic Review
    Moreira, Antonio H. J.
    Rodrigues, Nuno F.
    Pinho, Antonio C. M.
    Fonseca, Jaime C.
    Vilaca, Joao L.