The Influence of Impression Material on the Accuracy of the Master Cast in Implant Restorations

被引:0
|
作者
Stefos, Spyridon [1 ]
Kourtis, Stefanos [1 ]
Sarafianou, Aspasia [1 ]
Zoidis, Panagiotis [2 ]
机构
[1] Univ Athens, Dent Sch, Dept Prosthodont, Thivon Str 2, Athens, Greece
[2] Univ Florida, Coll Dent, Dept Restorat Sci, Div Prosthodont, Gainesville, FL USA
来源
OPEN DENTISTRY JOURNAL | 2018年 / 12卷
关键词
Impression materials; Implants; Addition type silicon; Polyether; Polyvinyl-siloxane impressions; Fixed Partial Denture (FPD);
D O I
10.2174/1874210601812011123
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The precise framework fit is important for the success of implant restorations. The purpose of the present study was to examine the effect of two different impression materials both of their medium viscosity on the master cast accuracy when parallel and inclined implants were used. Materials and Methods: An epoxy master cast with three implants was fabricated. The first two implants were parallel to each other and perpendicular to the horizontal plane and the third implant had a 25 inclination in reference to the other two. A passively fitting metal framework that was fabricated over this master cast was used to measure accuracy of fit. Five closed tray impressions for each medium viscosity material (polyether and polyvinyl-siloxane) tested were taken and the respective ten stone casts with three implant analogs were fabricated. The metal framework in the master cast, was fixed in the new specimens and the micro-gap between this prosthesis and the implant analogs was evaluated. The specimens were observed to an optical microscope and digital photography. Results and Conclusion: The data were statistically analysed using a computer software and t-test. Polyether exhibited higher micro-gap mean values (93,4 to 61,8 mu m) compared to polyvynil siloxane (30,47 to 14,83 mu m). The differences were statistically significant only for implant B. The categorical regression analysis (p < 0.01) for all implants showed that the marginal micro-gap was affected by the impression material (94.1%) and significantly by the type of it. The micro-gap values were higher for polyether compared to polyvinyl-siloxane. The torqued implant did not exhibit any statistically significant effect.
引用
收藏
页码:1123 / 1136
页数:14
相关论文
共 50 条
  • [1] Implant cast accuracy as a function of impression techniques and impression material viscosity
    Walker, Mary P.
    Ries, Dave
    Borello, Blake
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (04) : 669 - 674
  • [2] Effects of Implant System, Impression Technique, and Impression Material on Accuracy of the Working Cast
    Wegner, Kerstin
    Weskott, Katharina
    Zenginel, Martha
    Rehmann, Peter
    Woestmann, Bernd
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (04) : 989 - 995
  • [3] Influence of impression technique and material on the transfer accuracy of the implant position onto the working cast.
    Woestmann, B.
    Hassfurth, U.
    Balkenhol, M.
    Ferger, P.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B392 - B392
  • [4] Influence of impression technique and material on the accuracy of multiple implant impressions
    Woestmann, Bernd
    Rehmann, Peter
    Balkenhol, Markus
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (04) : 299 - 301
  • [5] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535
  • [6] IMPRESSION TECHNIQUE FOR CAST RESTORATIONS
    CULBREATH, JC
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1975, 33 (04): : 417 - 421
  • [7] Influence of impression material and time on the 3-dimensional accuracy of implant impressions
    Holst, Stefan
    Blatz, Markus B.
    Bergler, Michael
    Goellner, Matthias
    Wichmann, Manfred
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (01): : 67 - 73
  • [8] Comparative Evaluation of the Effects of Implant Position, Impression Material, and Tray Type on Implant Impression Accuracy
    Gokcen-Rohlig, Bilge
    Ongul, Deger
    Sancakli, Erkan
    Sermet, Bulent
    [J]. IMPLANT DENTISTRY, 2014, 23 (03) : 283 - 288
  • [9] Effect of Multiple Use of Impression Copings and Scanbodies on Implant Cast Accuracy
    Sawyers, Jordan
    Baig, Mirza Rustum
    ElMasoud, Bilal
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 891 - 898
  • [10] Accuracy of six dental stones for implant master cast fabrication
    Keefe, TF
    Frigerio, ML
    Powers, JM
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2371 - 2371