The Influence of Impression Material on the Accuracy of the Master Cast in Implant Restorations

被引:0
|
作者
Stefos, Spyridon [1 ]
Kourtis, Stefanos [1 ]
Sarafianou, Aspasia [1 ]
Zoidis, Panagiotis [2 ]
机构
[1] Univ Athens, Dent Sch, Dept Prosthodont, Thivon Str 2, Athens, Greece
[2] Univ Florida, Coll Dent, Dept Restorat Sci, Div Prosthodont, Gainesville, FL USA
来源
OPEN DENTISTRY JOURNAL | 2018年 / 12卷
关键词
Impression materials; Implants; Addition type silicon; Polyether; Polyvinyl-siloxane impressions; Fixed Partial Denture (FPD);
D O I
10.2174/1874210601812011123
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The precise framework fit is important for the success of implant restorations. The purpose of the present study was to examine the effect of two different impression materials both of their medium viscosity on the master cast accuracy when parallel and inclined implants were used. Materials and Methods: An epoxy master cast with three implants was fabricated. The first two implants were parallel to each other and perpendicular to the horizontal plane and the third implant had a 25 inclination in reference to the other two. A passively fitting metal framework that was fabricated over this master cast was used to measure accuracy of fit. Five closed tray impressions for each medium viscosity material (polyether and polyvinyl-siloxane) tested were taken and the respective ten stone casts with three implant analogs were fabricated. The metal framework in the master cast, was fixed in the new specimens and the micro-gap between this prosthesis and the implant analogs was evaluated. The specimens were observed to an optical microscope and digital photography. Results and Conclusion: The data were statistically analysed using a computer software and t-test. Polyether exhibited higher micro-gap mean values (93,4 to 61,8 mu m) compared to polyvynil siloxane (30,47 to 14,83 mu m). The differences were statistically significant only for implant B. The categorical regression analysis (p < 0.01) for all implants showed that the marginal micro-gap was affected by the impression material (94.1%) and significantly by the type of it. The micro-gap values were higher for polyether compared to polyvinyl-siloxane. The torqued implant did not exhibit any statistically significant effect.
引用
收藏
页码:1123 / 1136
页数:14
相关论文
共 50 条
  • [21] In vitro comparison of master cast accuracy for single-tooth implant replacement
    Vigolo, P
    Majzoub, Z
    Cordioli, C
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (05): : 562 - 566
  • [22] The effects of custom tray material on the accuracy of master cast reproduction.
    Kim, HK
    Chang, IT
    [J]. JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1354 - 1354
  • [23] Accuracy of complete-arch implant impression made with occlusal registration material
    Papazoglou, Efstratios
    Wee, Alvin G.
    Carr, Alan B.
    Urban, Istvan
    Margaritis, Vasileios
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 143 - 148
  • [24] In Vitro Implant Impression Accuracy Using a New Photopolymerizing SDR Splinting Material
    Di Fiore, Adolfo
    Meneghello, Roberto
    Savio, Gianpaolo
    Sivolella, Stefano
    Katsoulis, Joannis
    Stellini, Edoardo
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E721 - E729
  • [25] Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy
    Akalin, Zerrin Fidan
    Ozkan, Yasemin Kulak
    Ekerim, Ahmet
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 149 - 157
  • [26] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Elshenawy, Enas A.
    Alam-Eldein, Ahmed M.
    Abd Elfatah, Fadel A.
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [27] ACCURACY OF IMPRESSION TECHNIQUES IN IMPLANT DENTISTRY
    Alrumi, Bader Abdullah
    al Yami, Ibrahim Mohammed
    Alghamdi, Randah Abdulrhman
    Aldajani, Ali Mohammed
    Alhelaly, Hussein Mohammed
    Mohammed, Abdulrahman Thabet
    Abotaleb, Mohannd Talebalrahman
    Aljuaid, Mohammed Mbearak
    Alotaibi, Jamal Mousa
    Alelyani, Mohammed Dakhil
    [J]. INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (01): : 1396 - 1402
  • [28] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Enas A. Elshenawy
    Ahmed M. Alam-Eldein
    Fadel A. Abd Elfatah
    [J]. International Journal of Implant Dentistry, 4
  • [29] INFLUENCE OF IMPRESSION TRAYS ON IMPRESSION ACCURACY
    VANVUUREN, PAJ
    NEL, JC
    BRUNI, NB
    [J]. JOURNAL OF DENTAL RESEARCH, 1988, 67 (04) : 785 - 785
  • [30] Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial
    Arcuri, Lorenzo
    Pozzi, Alessandro
    Lio, Fabrizio
    Rompen, Eric
    Zechner, Werner
    Nardi, Alessandra
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (02) : 128 - 136