Predictors of patient radiation exposure during transcatheter aortic valve replacement

被引:6
|
作者
Goldsweig, Andrew M. [1 ,2 ,3 ]
Kennedy, Kevin F. [4 ]
Kolte, Dhaval [2 ,3 ]
Abbott, J. Dawn [2 ,3 ]
Gordon, Paul C. [2 ,3 ]
Sharaf, Barry L. [2 ,3 ]
Sellke, Frank W. [2 ,3 ]
Ehsan, Afshin [2 ,3 ]
Sodha, Neel R. [2 ,3 ]
Rutar, Frank [5 ]
Aronow, Herbert D. [2 ,3 ]
机构
[1] Univ Nebraska Med Ctr, Div Cardiol, Omaha, NE USA
[2] Brown Univ, Warren Alpert Med Sch, Div Cardiol, Providence, RI 02912 USA
[3] Lifespan Cardiovasc Inst, Providence, RI USA
[4] St Lukes Mid Amer Heart Inst, Midwest Bioinformat, Kansas City, MO USA
[5] Univ Nebraska Med Ctr, Dept Radiat Safety, Omaha, NE USA
关键词
angiographic; fluoroscopic imaging; radiation physics; dosimetry; transcatheter valve implantation; INTERMEDIATE-RISK PATIENTS; CORONARY-ANGIOGRAPHY; INTERVENTION; TIME;
D O I
10.1002/ccd.27452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter aortic valve replacement (TAVR) exposes patients to radiation. ObjectivesMethodsWe sought to identify factors associated with higher radiation exposure and to quantify their relative influence, which may inform reduction of this hazard. All TAVR procedures at Rhode Island Hospital between March 20, 2012 and February 12, 2017 were included. Procedures were performed by two co-primary operators using a Siemens Artis Zeego system. Radiation metrics were generated by the imaging system. The primary metric was dose-area product (DAP, Gy*cm(2)), and secondary metrics were reference point air kerma (mGy) and fluoroscopy time (minutes). Data collected for the STS/ACC TVT Registry were utilized to develop a multivariable linear regression model predicting DAP. ResultsConclusionIn 294 TAVRs, median DAP was 169 Gy*cm(2) [interquartile range (IQR) 106-238]. The r(2) values for the full 27-variable DAP model and reduced eight-variable model were 0.457 and 0.420, respectively. Valve area, aortic insufficiency, and procedure year (suggesting absence of a learning curve) were non-significant predictors in the full model, while increasing weight, cutdown transfemoral access, higher pre-procedure creatinine and hemoglobin, and vascular complications predicted higher DAP in both models. Results were unchanged when DAP was log-transformed. Secondary models for air kerma and fluoroscopy time revealed similar predictors. Factors associated with increased procedural complexity and duration as well as radiation attenuation and scatter predict increased patient radiation exposure during TAVR. Modification of procedural technique, especially using percutaneous femoral vascular access, may facilitate reduction in exposure.
引用
收藏
页码:768 / 774
页数:7
相关论文
共 50 条
  • [41] What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?
    Tourmousoglou, Christos
    Rao, Vivek
    Lalos, Spiros
    Dougenis, Dimitrios
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (06) : 837 - 843
  • [42] Transcatheter Aortic Valve Replacement For Symptomatic Aortic Insufficiency In A Patient With An LVAD
    Pannu, Viraaj
    Imburgio, Steven
    Odak, Mihir
    Duoedi, Steven
    Udongwo, Ndausung
    Mararenko, Anton
    Upadhyaya, Vandan
    Singh, Deepak
    Saybolt, Matthew D.
    JOURNAL OF CARDIAC FAILURE, 2024, 30 (01) : 303 - 303
  • [43] Redo Transcatheter Aortic Valve Replacement in a Young Patient With Congenital Aortic Valve Disease
    Tanner, Richard
    Prandi, Francesca R.
    Tan, Gilbert H. L.
    El-Hamams, Ismail
    Love, Barry A.
    Safi, Lucy M.
    Sharma, Samin K.
    Lerakis, Stamatios
    Kini, Annapooma S.
    JOURNAL OF INVASIVE CARDIOLOGY, 2025, 37 (01):
  • [44] Safe Transcatheter Aortic Valve Replacement in a Patient with a Highly Mobile Aortic Valve Mass
    Agbor-Etang, Brian B.
    Mukherjee, Ashis
    Sethi, Prabhdeep S.
    Pai, Ramdas G.
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2018, 27 (03) : 174 - 175
  • [45] Aortic valve replacement vs. transcatheter aortic valve implantation: Patient selection
    Ye, Jian
    Soon, Jia Lin
    Webb, John
    ANNALS OF CARDIOTHORACIC SURGERY, 2012, 1 (02) : 194 - 199
  • [46] Transcatheter Mitral Valve Replacement in the Transcatheter Aortic Valve Replacement Era
    Testa, Luca
    Rubbio, Antonio Popolo
    Casenghi, Matteo
    Pero, Gaetano
    Latib, Azeem
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [47] Transcatheter Aortic Valve Replacement after Transcatheter Mitral Valve Replacement
    Kaneko, Tsuyoshi
    Pelletier, Marc
    Berry, Natalia
    Sobieszczyk, Piotr
    Shah, Pinak
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2018, 2 (02): : 164 - 168
  • [48] Vascular management during transcatheter aortic valve replacement
    Takahiro Tokuda
    Masanori Yamamoto
    Cardiovascular Intervention and Therapeutics, 2023, 38 : 18 - 27
  • [49] Vascular management during transcatheter aortic valve replacement
    Tokuda, Takahiro
    Yamamoto, Masanori
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2023, 38 (01) : 18 - 27
  • [50] Vascular Complications During Transcatheter Aortic Valve Replacement
    Satler, Lowell F.
    Dvir, Danny
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (04) : 584 - 585