What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?

被引:21
|
作者
Tourmousoglou, Christos [1 ]
Rao, Vivek [2 ]
Lalos, Spiros [3 ]
Dougenis, Dimitrios [4 ]
机构
[1] Univ Ioannina, Sch Med, Ioannina 45332, Greece
[2] Univ Toronto, Toronto Gen Hosp, Peter Munk Cardiac Ctr, Div Cardiovasc Surg, Toronto, ON M5G 1L7, Canada
[3] Hippokrateion Hosp, Dept Cardiothorac Surg, Athens, Greece
[4] Univ Hosp Patra, Dept Cardiothorac Surg, Patras, Greece
关键词
Aortic valve; Failed; Bioprosthesis; Implantation; PREVIOUS CARDIAC-SURGERY; HEART-VALVES; IMPLANTATION; REOPERATION;
D O I
10.1093/icvts/ivv037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether transcatheter aortic valve-in-valve replacement (viv-TAVR) or redo aortic valve replacement (rAVR) is the best strategy in a patient with a degenerative bioprosthetic aortic valve. Altogether, 162 papers were found using the reported search, of which 12 represented the best evidence to answer the question. The authors, journal, date, country of publication, patient group, study type, outcomes and results of papers are tabulated. The results of the studies provided interesting results. All the studies are retrospective. Four papers reported the results of redo aortic valve replacement in patients with failed aortic bioprosthetic valve, six papers demonstrated their results with transcatheter aortic valve-in-valve replacement for the same indication and two papers reported their propensity-matched analysis of outcomes between viv-TAVR and rAVR in patients with previous cardiac surgery. Thirty-day mortality for rAVR was 2.3-15.5% and 0-17% for viv-TAVR. For rAVR, survival rate at 30 days was 83.6%, 76.1% at 1 year, 70.8% at 3 years, at 51.3-66% at 5 years, 61% at 8 years and 61.5% at 10 years. For viv-TAVR, the overall Kaplan-Meier survival rate at 1 year was 83.2%. After viv-TAVR at 1 year, 86.2% of surviving patients were at New York Heart Association (NYHA) class I/II. The complications after rAVR were stroke (4.6-5.8%), reoperation for bleeding (6.9-9.7%), low-cardiac output syndrome (9.9%) whereas complications after viv-TAVR at 30 days were major stroke (1.7%), aortic regurgitation of at least moderate degree (25%), new permanent pacemaker implantation rate (0-11%), ostial coronary obstruction (2%), need for implantation of a second device (5.7%) and major vascular complications (9.2%). It is noteworthy to mention that there is a valve-in-valve application that provides information to surgeons for choosing the correct size of the TAVR valve. Transcatheter aortic valve-in-valve procedures are clinically effective, at least in the short term, and could be an acceptable approach in selected high-risk patients with degenerative bioprosthetic valves. Redo AVR achieves acceptable medium and long-term results. Both techniques could be seen as complementary approaches for high-risk patients.
引用
收藏
页码:837 / 843
页数:7
相关论文
共 50 条
  • [1] Failed bioprosthetic valve approaches: Transcatheter aortic valve replacement approach
    Clark, Aaron
    Malaisrie, S. Chris
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 163 (05): : 1795 - 1798
  • [2] Valve-in-Valve Transcatheter Aortic Valve Replacement in Failed Trifecta Bioprosthetic Aortic Valve
    Zmaili, Mohammad
    Spilias, Nikolaos
    Ramu, Shivabalan Kathavarayan
    Prasad, Rohan
    Abushouk, Abdelrahman
    Harb, Serge
    Puri, Rishi
    Reed, Grant
    Yun, James
    Krishnaswamy, Amar
    Kapadia, Samir
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B285 - B286
  • [3] Redo Surgical Aortic Valve Replacement versus Valve in Valve Transcatheter Aortic Valve Replacement
    Patel, Parth M.
    Chiou, Edward
    Wei, Jane W.
    Binongo, Jose N.
    Guyton, Robert A.
    Leshnower, Bradley G.
    Grubb, Kendra J.
    Chen, Edward P.
    [J]. CIRCULATION, 2020, 142
  • [4] Redo Surgical Aortic Valve Replacement in the Era of Transcatheter Aortic Valve Replacement
    Jahangiri, Marjan
    [J]. ANNALS OF THORACIC SURGERY, 2023, 116 (04): : 767 - 767
  • [5] Meta-Analysis of Valve-in-Valve Transcatheter Aortic Valve Implantation Versus Redo-surgical Aortic Valve Replacement in Failed Bioprosthetic Aortic Valve
    Al-abcha, Abdullah
    Saleh, Yehia
    Boumegouas, Manel
    Prasad, Rohan
    Herzallah, Khader
    Baloch, Zulfiqar Qutrio
    Abdelkarim, Ola
    Rayamajhi, Supratik
    Abela, George S.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2021, 146 : 74 - 81
  • [6] Valve-in-Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement
    Pompeu, Michel
    Van den Eynde, Jef
    Simonato, Matheus
    Pibarot, Philippe
    Clavel, Marie-Annick
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (08) : 926 - 928
  • [7] Transcatheter Aortic Valve Replacement in Failed Transcatheter Bioprosthetic Valves
    Tarantini, Giuseppe
    Sathananthan, Janarthanan
    Fabris, Tommaso
    Landes, Uri
    Bapat, Vinayak N.
    Khan, Jaffar M.
    Fovino, Luca Nai
    Zaid, Syed
    Van Mieghem, Nicolas M.
    Latib, Azeem
    Waksman, Ron
    De Backer, Ole
    Rogers, Toby
    Sondergaard, Lars
    Tang, Gilbert H. L.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (18) : 1777 - 1793
  • [8] Valve-in-valve transcatheter aortic valve replacement versus redo aortic valve replacement: which procedure for which patient?
    Hutt, Erika
    Mehra, Nandini
    Desai, Milind Y.
    [J]. EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2022, 20 (12) : 911 - 918
  • [9] Valve-in-valve transcatheter aortic valve replacement versus isolated redo surgical aortic valve replacement
    Yousef, Sarah
    Serna-Gallegos, Derek
    Iyanna, Nidhi
    Kliner, Dustin
    Brown, James A.
    Toma, Catalin
    Makani, Amber
    West, David
    Wang, Yisi
    Thoma, Floyd W.
    Ahmad, Danial
    Yoon, Pyongsoo
    Chu, Danny
    Kaczorowski, David
    Bonatti, Johannes
    Sultan, Ibrahim
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 168 (04): : 1003 - 1010
  • [10] Transcatheter Aortic Valve Replacement for Bioprosthetic Aortic Valve Failure The Valve-in-Valve Procedure
    Webb, John G.
    Dvir, Danny