Predictors of patient radiation exposure during transcatheter aortic valve replacement

被引:6
|
作者
Goldsweig, Andrew M. [1 ,2 ,3 ]
Kennedy, Kevin F. [4 ]
Kolte, Dhaval [2 ,3 ]
Abbott, J. Dawn [2 ,3 ]
Gordon, Paul C. [2 ,3 ]
Sharaf, Barry L. [2 ,3 ]
Sellke, Frank W. [2 ,3 ]
Ehsan, Afshin [2 ,3 ]
Sodha, Neel R. [2 ,3 ]
Rutar, Frank [5 ]
Aronow, Herbert D. [2 ,3 ]
机构
[1] Univ Nebraska Med Ctr, Div Cardiol, Omaha, NE USA
[2] Brown Univ, Warren Alpert Med Sch, Div Cardiol, Providence, RI 02912 USA
[3] Lifespan Cardiovasc Inst, Providence, RI USA
[4] St Lukes Mid Amer Heart Inst, Midwest Bioinformat, Kansas City, MO USA
[5] Univ Nebraska Med Ctr, Dept Radiat Safety, Omaha, NE USA
关键词
angiographic; fluoroscopic imaging; radiation physics; dosimetry; transcatheter valve implantation; INTERMEDIATE-RISK PATIENTS; CORONARY-ANGIOGRAPHY; INTERVENTION; TIME;
D O I
10.1002/ccd.27452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter aortic valve replacement (TAVR) exposes patients to radiation. ObjectivesMethodsWe sought to identify factors associated with higher radiation exposure and to quantify their relative influence, which may inform reduction of this hazard. All TAVR procedures at Rhode Island Hospital between March 20, 2012 and February 12, 2017 were included. Procedures were performed by two co-primary operators using a Siemens Artis Zeego system. Radiation metrics were generated by the imaging system. The primary metric was dose-area product (DAP, Gy*cm(2)), and secondary metrics were reference point air kerma (mGy) and fluoroscopy time (minutes). Data collected for the STS/ACC TVT Registry were utilized to develop a multivariable linear regression model predicting DAP. ResultsConclusionIn 294 TAVRs, median DAP was 169 Gy*cm(2) [interquartile range (IQR) 106-238]. The r(2) values for the full 27-variable DAP model and reduced eight-variable model were 0.457 and 0.420, respectively. Valve area, aortic insufficiency, and procedure year (suggesting absence of a learning curve) were non-significant predictors in the full model, while increasing weight, cutdown transfemoral access, higher pre-procedure creatinine and hemoglobin, and vascular complications predicted higher DAP in both models. Results were unchanged when DAP was log-transformed. Secondary models for air kerma and fluoroscopy time revealed similar predictors. Factors associated with increased procedural complexity and duration as well as radiation attenuation and scatter predict increased patient radiation exposure during TAVR. Modification of procedural technique, especially using percutaneous femoral vascular access, may facilitate reduction in exposure.
引用
收藏
页码:768 / 774
页数:7
相关论文
共 50 条
  • [31] Predictors of Hospital Readmissions After Transcatheter Aortic Valve Replacement
    Harvey, James
    Clancy, Seth
    Rutkin, Bruce
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B13 - B14
  • [32] Mitral valve perforation during transcatheter aortic valve replacement
    Higa, Shotaro
    Nagano, Takaaki
    Yamashiro, Satoshi
    Iwabuchi, Masashi
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2020, 28 (05): : 276 - 278
  • [33] Transcatheter aortic valve replacement valve in transcatheter aortic valve replacement valve for severe periprosthetic regurgitation
    Nandy, Sneha
    Wan, Siu-Hin
    Klarich, Kyle
    HEART VIEWS, 2020, 21 (01): : 49 - 51
  • [34] MIXED AORTIC VALVE DISEASE IN A PATIENT WITH RADIATION-INDUCED RESTRICTIVE CARDIOMYOPATHY: ROLE OF TRANSCATHETER AORTIC VALVE REPLACEMENT
    Kumar, Vishesh
    Coylewright, Megan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1115 - 1115
  • [35] Aortic Valve Deformation During Transcatheter Mitral Valve Replacement
    Sugiura, Atsushi
    Weber, Marcel
    Treede, Hendrik
    Nickenig, Georg
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (13) : 1603 - 1604
  • [36] Avulsion of Aortic Leaflet During Transcatheter Aortic Valve Replacement
    Patankar, Gautam R.
    Grayburn, Paul A.
    Hebeler, Robert F., Jr.
    Henry, Albert C.
    Stoler, Robert C.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (05) : 549 - 551
  • [37] Aortic Root Intussusception During Transcatheter Aortic Valve Replacement
    Jubran, Ayman
    Flugelman, Moshe Y.
    Khader, Nader
    Jaffe, Ronen
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (19) : E195 - E196
  • [38] CLINICAL PREDICTORS AND OUTCOME IMPACT OF VALVE-IN-VALVE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Medranda, Giorgio
    Brahmbhatt, Kunal
    Salhab, Khaled
    Schwartz, Richard
    Green, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1259 - 1259
  • [39] RADIATION EXPOSURE REDUCTION DURING TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) PROCEDURES
    Sharma, D.
    Ramsewak, A.
    O'connaire, S.
    Verghis, R.
    Manoharan, G.
    Spence, M. S.
    HEART, 2013, 99 : A34 - A34
  • [40] Transcatheter Aortic Valve Implantation in a Patient with Previous Mitral Valve Replacement
    Moon, Sung Woo
    Ko, Young-Guk
    Hong, Geu-Ru
    Lee, Sak
    Chang, Byung-Chul
    Shim, Jae-Kwang
    Kwak, Young-Ran
    Hong, Myeong-Ki
    KOREAN CIRCULATION JOURNAL, 2014, 44 (05) : 344 - 347