Predictors of patient radiation exposure during transcatheter aortic valve replacement

被引:6
|
作者
Goldsweig, Andrew M. [1 ,2 ,3 ]
Kennedy, Kevin F. [4 ]
Kolte, Dhaval [2 ,3 ]
Abbott, J. Dawn [2 ,3 ]
Gordon, Paul C. [2 ,3 ]
Sharaf, Barry L. [2 ,3 ]
Sellke, Frank W. [2 ,3 ]
Ehsan, Afshin [2 ,3 ]
Sodha, Neel R. [2 ,3 ]
Rutar, Frank [5 ]
Aronow, Herbert D. [2 ,3 ]
机构
[1] Univ Nebraska Med Ctr, Div Cardiol, Omaha, NE USA
[2] Brown Univ, Warren Alpert Med Sch, Div Cardiol, Providence, RI 02912 USA
[3] Lifespan Cardiovasc Inst, Providence, RI USA
[4] St Lukes Mid Amer Heart Inst, Midwest Bioinformat, Kansas City, MO USA
[5] Univ Nebraska Med Ctr, Dept Radiat Safety, Omaha, NE USA
关键词
angiographic; fluoroscopic imaging; radiation physics; dosimetry; transcatheter valve implantation; INTERMEDIATE-RISK PATIENTS; CORONARY-ANGIOGRAPHY; INTERVENTION; TIME;
D O I
10.1002/ccd.27452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter aortic valve replacement (TAVR) exposes patients to radiation. ObjectivesMethodsWe sought to identify factors associated with higher radiation exposure and to quantify their relative influence, which may inform reduction of this hazard. All TAVR procedures at Rhode Island Hospital between March 20, 2012 and February 12, 2017 were included. Procedures were performed by two co-primary operators using a Siemens Artis Zeego system. Radiation metrics were generated by the imaging system. The primary metric was dose-area product (DAP, Gy*cm(2)), and secondary metrics were reference point air kerma (mGy) and fluoroscopy time (minutes). Data collected for the STS/ACC TVT Registry were utilized to develop a multivariable linear regression model predicting DAP. ResultsConclusionIn 294 TAVRs, median DAP was 169 Gy*cm(2) [interquartile range (IQR) 106-238]. The r(2) values for the full 27-variable DAP model and reduced eight-variable model were 0.457 and 0.420, respectively. Valve area, aortic insufficiency, and procedure year (suggesting absence of a learning curve) were non-significant predictors in the full model, while increasing weight, cutdown transfemoral access, higher pre-procedure creatinine and hemoglobin, and vascular complications predicted higher DAP in both models. Results were unchanged when DAP was log-transformed. Secondary models for air kerma and fluoroscopy time revealed similar predictors. Factors associated with increased procedural complexity and duration as well as radiation attenuation and scatter predict increased patient radiation exposure during TAVR. Modification of procedural technique, especially using percutaneous femoral vascular access, may facilitate reduction in exposure.
引用
收藏
页码:768 / 774
页数:7
相关论文
共 50 条
  • [21] Aortic Valve Disease, Transcatheter Aortic Valve Replacement, and the Heart Failure Patient
    Okumus, Nazli
    Abraham, Sonu
    Puri, Rishi
    Tang, W. H. Wilson
    JACC-HEART FAILURE, 2023, 11 (08) : 1070 - 1083
  • [22] Transcatheter aortic valve replacement The American perspective on transcatheter aortic valve replacement
    Waksman, Ron
    Rogers, Toby
    EUROPEAN HEART JOURNAL, 2016, 37 (10) : 797 - 799
  • [23] TRANSCATHETER AORTIC VALVE REPLACEMENT IN A PATIENT WITH VERY MOBILE AORTIC VALVE MASS
    Agbor-Etang, Brian
    Lee, Hong Seok
    Mukherjee, Ashis
    Sethi, Prabhdeep
    Nazzal, Sami
    Malki, Alan
    Gibson, Christopher
    Pai, Ramdas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 2428 - 2428
  • [24] Transcatheter aortic valve replacement in a patient with Werner syndrome
    Masada, Kenta
    Kuratani, Toru
    Maeda, Koichi
    Torikai, Kei
    Sawa, Yoshiki
    JOURNAL OF CARDIAC SURGERY, 2017, 32 (07) : 414 - 415
  • [25] PREDICTORS OF PACEMAKER DEPENDENCY AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Lee, Mark
    Yeshwant, Srinath
    Chava, Sreedivya
    Dauerman, Harold
    Lustgarten, Daniel
    Lobel, Robert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 782 - 782
  • [26] PREDICTORS OF READMISSION FOLLOWING TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR)
    Galla, John
    Amritphale, Amod
    Galla, John M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 742 - 742
  • [27] Transcatheter Aortic Valve Replacement in a Patient with an Impossible Airway
    Banoub, Mounir
    ANESTHESIA AND ANALGESIA, 2024, 139 (06): : 290 - 291
  • [28] Geometric Predictors of Stroke After Transcatheter Aortic Valve Replacement
    Vogl, Brennan
    Vitale, Emily
    Wang, Zhenyu
    Sularz, Agata
    Ponce, Alejandra Chavez
    Lo Russo, Gerardo V.
    Alarouri, Hasan S.
    Alkhouli, Mohamad
    Hatoum, Hoda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B165 - B166
  • [29] PREDICTORS OF PACEMAKER USE AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Phan, Derek
    Lee, Ming-Sum
    Wassie, Maereg
    Goitia, Jesse
    Nadadur, Malini
    Aharonian, Vicken
    Mansukhani, Prakash
    Moore, Naing
    Brar, Somjot
    Zadegan, Ray
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1442 - 1442
  • [30] Predictors and outcomes of stroke after transcatheter aortic valve replacement
    Hatfield, Sarah A.
    Nores, Marcos A.
    James, Taylor M.
    Rothenberg, Mark
    Kapila, Arvind
    Cubeddu, Roberto J.
    Stamou, Sotiris C.
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (01) : 21 - 27