Development of high-performance liquid chromatography-electrospray mass spectrometry with size-exclusion chromatography for determination of acrylamide in fried foods

被引:5
|
作者
Inoue, K [1 ]
Yoshimura, Y [1 ]
Nakazawa, H [1 ]
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, Tokyo 1428501, Japan
关键词
acrylamide; liquid chromatography mass spectrometry; size-exclusion chromatography; fried food;
D O I
10.1081/JLC-120021756
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method by liquid chromatography-electrospray mass spectrometry (LC/MS) with a size-exclusion chromatography column for the analysis of acrylamide in fried foods, is reported. In the mass spectral analysis using an electrospray MS, the signal at m/z 72, which was assigned to the [M+H](+) ion, was observed as the main peak. The main m/z signal showed a maximum at the firagmentor voltage of 100 V The retention time for the elution of acrylamide from the size-exclusion chromatography column ranged from 15 to 20 min, and the eluate was analyzed by LC/MS with a reversed-phase column. A linear response was found for the acrylamide standard tested within the concentration range of 5.0-1000 ng/mL, with correlation coefficients (r) greater than 0.99. Sample preparation was performed by means of solvent extraction, which gave acrylamide recoveries higher than 90% with relative standard deviations less than 10%, with C-13-labeled acrylamide standard.
引用
收藏
页码:1877 / 1884
页数:8