Quantification of zolmitriptan in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry

被引:23
|
作者
Zhang, ZJ [1 ]
Xu, FG
Tian, Y
Li, W
Mao, GG
机构
[1] China Pharmaceut Univ, Ctr Instrumental Anal, Nanjing 210009, Peoples R China
[2] Wannan Med Coll, Dept Clin Pharmacol, Wuhu 241000, Peoples R China
关键词
zolmitriptan; HPLC-ESI-MS; human plasma; pharmacokinetics;
D O I
10.1016/j.jchromb.2004.09.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of zolmitriptan in human plasma. After the addition of the internal standard (IS) and 1.0 M sodium hydroxide solution, plasma samples were extracted with methylene chloride:ethyl acetate mixture (20:80, v/v). The organic layer was evaporated under a stream of nitrogen at 40degreesC. The residue was reconstituted with 100 RI mobile phase. The compounds were separated on a prepacked Lichrospher CN (5 mum, 150 mm x 2.0 mm) column using a mixture of methanol:water (10 mM NH(4)AC, pH 4.0) = 78:22 as mobile phase. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.30-16.0 ng/mI with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (R.S.D.%) were lower than 15% and accuracy ranged from 85 to 115%. The lower limit of quantification was identifiable and reproducible at 0.30 ng/ml. The proposed method enables the unambiguous identification and quantification of zolmitriptan for pharmacokinetic, bioavailability or bioequivalence studies. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 50 条
  • [1] Quantification of lipoic acid in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Chen, J
    Jiang, WM
    Cai, J
    Tao, WX
    Gao, XL
    Jiang, XG
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 249 - 257
  • [2] Determination of oxatomide in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    She, Xiaodong
    Wu, Lili
    Wei, Huilin
    Liu, Weida
    Chen, Yun
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 746 - 752
  • [3] Quantification of voriconazole in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry: application to a bioequivalence study
    Cheng, Ying
    Zhang, Zun-Jian
    Tian, Yuan
    Li, Wen-Jing
    Wei, Wei
    [J]. ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (02): : 132 - 139
  • [4] High-performance liquid chromatography-electrospray ionization mass spectrometry determination of sodium ferulate in human plasma
    Yang, Cheng
    Tian, Yuan
    Zhang, Zunjian
    Xu, Fengguo
    Chen, Yun
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 945 - 950
  • [5] Quantification of cardiolipin by liquid chromatography-electrospray ionization mass spectrometry
    Garrett, Teresa A.
    Kordestani, Reza
    Raetz, Christian R. H.
    [J]. LIPIDOMICS AND BIOACTIVE LIPIDS: SPECIALIZED ANALYTICAL METHODS AND LIPIDS IN DISEASE, 2007, 433 : 213 - 230
  • [6] Identification and quantification of microcystins in water by high performance liquid chromatography-electrospray ionization mass spectrometry
    Yu, RP
    Tao, GJ
    Qing, F
    Chen, Y
    Tang, J
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (12) : 1462 - 1464
  • [7] Liquid chromatography-electrospray ionization tandem mass spectrometry for the quantification of styraxlignolide A in rat plasma
    Ji, Hye Y.
    Oh, Sei-Ryang
    Lee, Hyeong-Kyu
    Na, Dong H.
    Lee, Hye S.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1828 - 1833
  • [8] Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Bhatt, Jignesh
    Jangid, Arvind
    Shetty, Raghavendra
    Shah, Bhavin
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 736 - 742
  • [9] High-performance liquid chromatography-electrospray ionization mass spectrometry determination of mitiglinide in human plasma and its pharmacokinetics
    Liang, Jiabi
    Tian, Yuan
    Zhang, Zunjian
    Feng, Shudan
    Zhao, Yanan
    Mao, Guoguang
    [J]. JOURNAL OF MASS SPECTROMETRY, 2007, 42 (02): : 171 - 177
  • [10] High-performance liquid chromatography-electrospray ionization mass spectrometry method for the measurement of moclobemide and two metabolites in plasma
    Hoskins, JM
    Gross, AS
    Shenfield, GM
    Rivory, LP
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (02): : 319 - 326