Development of high-performance liquid chromatography-electrospray mass spectrometry with size-exclusion chromatography for determination of acrylamide in fried foods

被引:5
|
作者
Inoue, K [1 ]
Yoshimura, Y [1 ]
Nakazawa, H [1 ]
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, Tokyo 1428501, Japan
关键词
acrylamide; liquid chromatography mass spectrometry; size-exclusion chromatography; fried food;
D O I
10.1081/JLC-120021756
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method by liquid chromatography-electrospray mass spectrometry (LC/MS) with a size-exclusion chromatography column for the analysis of acrylamide in fried foods, is reported. In the mass spectral analysis using an electrospray MS, the signal at m/z 72, which was assigned to the [M+H](+) ion, was observed as the main peak. The main m/z signal showed a maximum at the firagmentor voltage of 100 V The retention time for the elution of acrylamide from the size-exclusion chromatography column ranged from 15 to 20 min, and the eluate was analyzed by LC/MS with a reversed-phase column. A linear response was found for the acrylamide standard tested within the concentration range of 5.0-1000 ng/mL, with correlation coefficients (r) greater than 0.99. Sample preparation was performed by means of solvent extraction, which gave acrylamide recoveries higher than 90% with relative standard deviations less than 10%, with C-13-labeled acrylamide standard.
引用
收藏
页码:1877 / 1884
页数:8
相关论文
共 50 条
  • [41] Determination of Polysaccharide in Radix pseudostellariae Extract by Size-Exclusion High-Performance Liquid Chromatography
    陈芸芸
    丁怡
    王伟
    王如峰
    苏慧
    杜力军
    Tsinghua Science and Technology, 2007, (04) : 389 - 393
  • [42] Determination of enalapril in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Yoon, KH
    Kim, W
    Park, J
    Kim, HJ
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (06): : 878 - 880
  • [43] Determination of fumonisin in food by high performance liquid chromatography-electrospray ionization tandem mass spectrometry
    Liu, CL
    Xu, WN
    Kofoet, A
    Liu, FM
    Pan, CP
    Xu, YJ
    Jiang, SR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (11) : 1619 - 1622
  • [44] Determination of Acrylamide in Fried Starchy Foods by Gas Chromatography-Mass Spectrometry
    Zhong Weike
    Chen Dongdong
    Yong Wei
    Liu Zhiming
    Qiu Yueming
    Tang Yingzhang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 312 - 314
  • [45] High-performance liquid chromatography electrospray mass spectrometry of retinoids
    vanBreemen, RB
    Huang, CR
    FASEB JOURNAL, 1996, 10 (09): : 1098 - 1101
  • [46] Optimized analytical method for cyclosporin A by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Zhou, L
    Tan, D
    Theng, J
    Lim, L
    Liu, YP
    Lam, KW
    JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (01): : 201 - 207
  • [47] Analysis of Paeoniae Radix by High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry
    Xinfeng Zhao
    Yuqing Sun
    Analytical Sciences, 2003, 19 : 1313 - 1315
  • [48] Quantification of lipoic acid in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Chen, J
    Jiang, WM
    Cai, J
    Tao, WX
    Gao, XL
    Jiang, XG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 249 - 257
  • [49] Analysis of Paeoniae Radix by high-performance liquid chromatography-electrospray ionization-mass spectrometry
    Zhao, XF
    Sun, YQ
    ANALYTICAL SCIENCES, 2003, 19 (09) : 1313 - 1315
  • [50] HIGH-PERFORMANCE SIZE-EXCLUSION LIQUID-CHROMATOGRAPHY OF PROTECTED PEPTIDES
    ULYASHIN, VV
    DEIGIN, VI
    IVANOV, VT
    OVCHINNIKOV, YA
    JOURNAL OF CHROMATOGRAPHY, 1981, 215 (1-3): : 263 - 277