Reliability of an in-shoe pressure measurement system during treadmill walking

被引:132
|
作者
Kernozek, TW
LaMott, EE
Dancisak, MJ
机构
[1] COLL ST CATHERINE,PHYS THERAPY PROGRAM,MINNEAPOLIS,MN
[2] CONCORDIA COLL,DEPT HLTH & PHYS EDUC,ST PAUL,MN
关键词
D O I
10.1177/107110079601700404
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined the reliability of in-shoe foot pressure measurement using the Pedar in-shoe pressure measurement system for 25 participants walking at treadmill speeds of 0.89, 1.12, and 1.34 meters/sec, The measurement system uses EMED insoles, which consist of 99 capacitive sensors, sampled at 50 Hz, Data were collected for 20 seconds at two separate times while participants walked at each gait speed. Differences in some of the loading variables across speed relative to the total foot and across the different anatomical regions were detected, Different anatomical regions of the foot were loaded differently with variations in walking speed, The results indicated the need to control speed when evaluating loading parameters using in-shoe pressure measurement techniques, Coefficients of reliability were calculated, Variables such as peak force for the total foot required two steps to achieve a coefficient of reliability of 0.98. To achieve excellent reliability (>0.90) in the peak force, force time integral, peak pressure, and pressure time integral across the total foot and the seven regions, a maximum of eight steps was needed, In general, timing variables, such as the instant of peak force and the instant of peak pressure, tended to be the least reliable measures.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [41] Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop
    Christensen, Birgitte H.
    Andersen, Kathrine S.
    Pedersen, Kristina S.
    Bengtsen, Britt S.
    Simonsen, Ole
    Kappel, Simon L.
    Rathleff, Michael S.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2014, 7
  • [42] Intrasession Reliability Of Insole In-shoe Plantar Pressure Measurements In Different Foot Areas
    Koenig, Niklas
    Stoll, Andreas
    Mayer, Frank
    Baur, Heiner
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 941 - 941
  • [43] Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop
    Birgitte H Christensen
    Kathrine S Andersen
    Kristina S Pedersen
    Britt S Bengtsen
    Ole Simonsen
    Simon L Kappel
    Michael S Rathleff
    Journal of Foot and Ankle Research, 7
  • [44] Observations on the F-Scan in-shoe pressure measuring system
    Woodburn, J
    Helliwell, PS
    CLINICAL BIOMECHANICS, 1996, 11 (05) : 301 - 304
  • [45] MEASUREMENT OF PRESSURE DISTRIBUTION OF SHOE SOLE DURING WALKING AND ITS RELATION TO SLIPPAGE
    Yoshioka, Y.
    Iwai, T.
    Shoukaku, Y.
    PROCEEDINGS OF THE ASME/STLE INTERNATIONAL JOINT TRIBOLOGY CONFERENCE - 2011, 2012, : 47 - 49
  • [46] Wireless In-shoe Force System
    Lawrence, TL
    Schmidt, RN
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2238 - 2241
  • [47] Evaluation of Two Approaches for Aligning Data Obtained from a Motion Capture System and an In-Shoe Pressure Measurement System
    Kim, Sunwook
    Nussbaum, Maury A.
    SENSORS, 2014, 14 (09) : 16994 - 17007
  • [48] An in-shoe device to measure plantar pressure during daily human activity
    Saito, M.
    Nakajima, K.
    Takano, C.
    Ohta, Y.
    Sugimoto, C.
    Ezoe, R.
    Sasaki, K.
    Hosaka, H.
    Ifukube, T.
    Ino, S.
    Yamashita, K.
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (05) : 638 - 645
  • [49] Effect of shoe modifications on center of pressure and in-shoe plantar pressures
    Xu, H
    Akai, M
    Kakurai, S
    Yokota, K
    Kaneko, H
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1999, 78 (06) : 516 - 524
  • [50] Effect of shoe modifications on center of pressure and in-shoe plantar pressures
    Xu, Hong
    Akai, Masami
    Kakurai, Shuichi
    Yokota, Kazuhiko
    Kaneko, Hideo
    American Journal of Physical Medicine and Rehabilitation, 78 (06): : 516 - 524