Reliability of an in-shoe pressure measurement system during treadmill walking

被引:132
|
作者
Kernozek, TW
LaMott, EE
Dancisak, MJ
机构
[1] COLL ST CATHERINE,PHYS THERAPY PROGRAM,MINNEAPOLIS,MN
[2] CONCORDIA COLL,DEPT HLTH & PHYS EDUC,ST PAUL,MN
关键词
D O I
10.1177/107110079601700404
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined the reliability of in-shoe foot pressure measurement using the Pedar in-shoe pressure measurement system for 25 participants walking at treadmill speeds of 0.89, 1.12, and 1.34 meters/sec, The measurement system uses EMED insoles, which consist of 99 capacitive sensors, sampled at 50 Hz, Data were collected for 20 seconds at two separate times while participants walked at each gait speed. Differences in some of the loading variables across speed relative to the total foot and across the different anatomical regions were detected, Different anatomical regions of the foot were loaded differently with variations in walking speed, The results indicated the need to control speed when evaluating loading parameters using in-shoe pressure measurement techniques, Coefficients of reliability were calculated, Variables such as peak force for the total foot required two steps to achieve a coefficient of reliability of 0.98. To achieve excellent reliability (>0.90) in the peak force, force time integral, peak pressure, and pressure time integral across the total foot and the seven regions, a maximum of eight steps was needed, In general, timing variables, such as the instant of peak force and the instant of peak pressure, tended to be the least reliable measures.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [31] A PORTABLE IN-SHOE PRESSURE MONITOR
    LEVIN, MR
    REINECK, KM
    HESSELINK, J
    VAUGHAN, CL
    JOURNAL OF BIOMECHANICS, 1986, 19 (06) : 475 - 475
  • [32] Validation of In-Shoe Force Sensors during Loaded Walking in Military Personnel
    Kong, Pui Wah
    Iskandar, Muhammad Nur Shahril
    Koh, Ang Hong
    Ho, Mei Yee Mavis
    Lim, Cheryl Xue Er
    SENSORS, 2023, 23 (14)
  • [33] The reliability of the Adelaide in-shoe foot model
    Bishop, Chris
    Hillier, Susan
    Thewlis, Dominic
    GAIT & POSTURE, 2017, 56 : 1 - 7
  • [34] Use of in-shoe pressure to quantify running shoe fit
    Harrison, Kathryn
    Vladika, Brett
    Feeney, Daniel
    FOOTWEAR SCIENCE, 2021, 13 (S1) : S71 - S72
  • [35] Plantar pressure measurements using an in-shoe system and a pressure platform: A comparison
    Chevalier, Thierry Larose
    Hodgins, Helen
    Chockalingam, Nachiappan
    GAIT & POSTURE, 2010, 31 (03) : 397 - 399
  • [36] Software-Defined Design of In-shoe Plantar Pressure Measurement Mechanism
    Lee, Chao-Hsien
    Wu, Hsin-Liang
    2023 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, ICCE, 2023,
  • [37] Differences of the in-shoe plantar pressures during walking and running in different tennis shoes
    Peharec, S
    Rosanda, D
    Cifrek, M
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 651 - 654
  • [38] In-shoe plantar pressure measurement technologies for the diabetic foot: A systematic review
    Castro-Martins, Pedro
    Marques, Arcelina
    Coelho, Luis
    Vaz, Mario
    Baptista, Joao Santos
    HELIYON, 2024, 10 (09)
  • [39] Validity and repeatability of three commercially available in-shoe pressure measurement systems
    Carina Price
    Daniel Parker
    Christopher J Nester
    Journal of Foot and Ankle Research, 7 (Suppl 1)
  • [40] In-shoe biaxial shear force measurement: The Kent shear system
    Akhlaghi, F
    Pepper, MG
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (04) : 315 - 317