Reliability of an in-shoe pressure measurement system during treadmill walking

被引:132
|
作者
Kernozek, TW
LaMott, EE
Dancisak, MJ
机构
[1] COLL ST CATHERINE,PHYS THERAPY PROGRAM,MINNEAPOLIS,MN
[2] CONCORDIA COLL,DEPT HLTH & PHYS EDUC,ST PAUL,MN
关键词
D O I
10.1177/107110079601700404
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined the reliability of in-shoe foot pressure measurement using the Pedar in-shoe pressure measurement system for 25 participants walking at treadmill speeds of 0.89, 1.12, and 1.34 meters/sec, The measurement system uses EMED insoles, which consist of 99 capacitive sensors, sampled at 50 Hz, Data were collected for 20 seconds at two separate times while participants walked at each gait speed. Differences in some of the loading variables across speed relative to the total foot and across the different anatomical regions were detected, Different anatomical regions of the foot were loaded differently with variations in walking speed, The results indicated the need to control speed when evaluating loading parameters using in-shoe pressure measurement techniques, Coefficients of reliability were calculated, Variables such as peak force for the total foot required two steps to achieve a coefficient of reliability of 0.98. To achieve excellent reliability (>0.90) in the peak force, force time integral, peak pressure, and pressure time integral across the total foot and the seven regions, a maximum of eight steps was needed, In general, timing variables, such as the instant of peak force and the instant of peak pressure, tended to be the least reliable measures.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [21] Reliability of F-Scan in-shoe measurements of plantar pressure
    Ahroni, JH
    Boyko, EJ
    Forsberg, R
    FOOT & ANKLE INTERNATIONAL, 1998, 19 (10) : 668 - 673
  • [22] The difference of in-shoe plantar pressure between level walking and stair walking in healthy males
    Cho, Yun Jae
    Lee, Choongho
    Lee, Jae Hee
    Kyung, Min Gyu
    Lee, Kyung Hwan
    Lee, Dong Yeon
    JOURNAL OF BIOMECHANICS, 2021, 122
  • [23] INCREASED IN-SHOE PRESSURE-TIME INTEGRALS DURING WALKING IN PATIENTS WITH DIABETIC SENSORY NEUROPATHY
    LEMKES, HHPJ
    TJONATSIEN, AML
    RIETKERK, MG
    VANDERPAUW, MTM
    DIABETOLOGIA, 1994, 37 : A204 - A204
  • [24] Influence of in-shoe heel lifts on plantar pressure and center of pressure in the medial-lateral direction during walking
    Zhang, Xianyi
    Li, Bo
    GAIT & POSTURE, 2014, 39 (04) : 1012 - 1016
  • [25] Reliability of in-shoe plantar pressure measurements in rheumatoid arthritis patients
    Vidmar, Gaj
    Novak, Primoz
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2009, 32 (01) : 36 - 40
  • [26] Wearing the F-Scan mobile in-shoe pressure measurement system alters gait characteristics during running
    Kong, Pui W.
    De Heer, Hendrik
    GAIT & POSTURE, 2009, 29 (01) : 143 - 145
  • [27] Reliability of a multi-segment foot model in a neutral cushioning shoe during treadmill walking
    Balsdon, Megan E. R.
    Dombroski, Colin E.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2018, 11
  • [28] Reliability of a multi-segment foot model in a neutral cushioning shoe during treadmill walking
    Megan E. R. Balsdon
    Colin E. Dombroski
    Journal of Foot and Ankle Research, 11
  • [29] Detection of gait events using an F-Scan in-shoe pressure measurement system
    Catalfamo, Paola
    Moser, David
    Ghoussayni, Salim
    Ewins, David
    GAIT & POSTURE, 2008, 28 (03) : 420 - 426
  • [30] The Pedar® in-shoe system:: Repeatability and normal pressure values
    Putti, A. B.
    Arnold, G. P.
    Cochrane, L.
    Abboud, R. J.
    GAIT & POSTURE, 2007, 25 (03) : 401 - 405