Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop

被引:13
|
作者
Christensen, Birgitte H. [1 ,2 ]
Andersen, Kathrine S. [1 ,3 ]
Pedersen, Kristina S. [3 ]
Bengtsen, Britt S. [3 ]
Simonsen, Ole [1 ]
Kappel, Simon L. [4 ]
Rathleff, Michael S. [1 ]
机构
[1] Aalborg Univ Hosp, Orthopaed Surg Res Unit, Aalborg, Denmark
[2] Aalborg Univ Hosp, Dept Occupat & Physiotherapy, Aalborg, Denmark
[3] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[4] Aarhus Univ, Aarhus Sch Engn, Signal Proc & Control Grp, Aarhus, Denmark
来源
关键词
Navicular drop; Foot kinematics; In-shoe; Stretch-sensor; FOOT MOBILITY; PAIN; KINEMATICS; AGREEMENT; PRONATION; ORTHOSES; INJURIES; EXERCISE; WALKING; TRIAL;
D O I
10.1186/1757-1146-7-12
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Increased navicular drop is associated with increased risk of lower extremity overuse injuries and foot orthoses are often prescribed to reduce navicular drop. For laboratory studies, transparent shoes may be used to monitor the effect of orthoses but no clinically feasible methods exist. We have developed a stretch-sensor that allows for in-shoe measurement of navicular drop but the reliability and validity is unknown. The purpose of this study was to investigate: 1) the reliability of the stretch-sensor for measuring navicular drop, and 2) the concurrent validity of the stretch-sensor compared to the static navicular drop test. Methods: Intra-and inter-rater reliability was tested on 27 participants walking on a treadmill on two separate days. The stretch-sensor was positioned 20 mm posterior to the tip of the medial malleolus and 20 mm posterior to the navicular tuberosity. The participants walked six minutes on the treadmill before navicular drop was measured. Reliability was quantified by the Intraclass Correlation Coefficient (ICC 2.1) and agreement was quantified by Limits of Agreement (LOA). To assess concurrent validity, static navicular drop was measured with the stretch-sensor and compared with static navicular drop measured with a ruler on 27 new participants. Linear regression was used to measure concurrent validity. Results: The reliability of the stretch-sensor was acceptable for barefoot measurement (intra-and inter-rater ICC: 0.76-0.84) but lower for in-shoe measurement (ICC: 0.65). There was a significant association between static navicular drop measured with the stretch-sensor compared with a ruler (r = 0.745, p < 0.001). Conclusion: This study suggests that the stretch-sensor has acceptable reliability for dynamic barefoot measurement of navicular drop. Furthermore, the stretch-sensor shows concurrent validity compared with the static navicular drop test as performed by Brody. This new simple method may hold promise for both clinical assessment and research but more work is needed before the method can be recommended.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop
    Birgitte H Christensen
    Kathrine S Andersen
    Kristina S Pedersen
    Britt S Bengtsen
    Ole Simonsen
    Simon L Kappel
    Michael S Rathleff
    Journal of Foot and Ankle Research, 7
  • [2] A Novel Method for Measuring In-Shoe Navicular Drop during Gait
    Kappel, Simon L.
    Rathleff, Michael S.
    Hermann, Dan
    Simonsen, Ole
    Karstoft, Henrik
    Ahrendt, Peter
    SENSORS, 2012, 12 (09): : 11697 - 11711
  • [3] Validity and reliability of the XSENSOR in-shoe pressure measurement system
    Parker, Daniel
    Andrews, Jennifer
    Price, Carina
    PLOS ONE, 2023, 18 (01):
  • [4] Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements
    Chesnin, KJ
    Selby-Silverstein, L
    Besser, MP
    GAIT & POSTURE, 2000, 12 (02) : 128 - 133
  • [5] Validity and repeatability of three in-shoe pressure measurement systems
    Price, Carina
    Parker, Daniel
    Nester, Christopher
    GAIT & POSTURE, 2016, 46 : 69 - 74
  • [6] Test-retest Reliability And Concurrent Validity Of An In-shoe Pressure System During Two Landing Maneuvers
    Alanazi, Ahmad D.
    Mitchell, Katy
    Roddey, Toni
    Alenazi, Aqeel
    Ortiz, Alexis
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 936 - 936
  • [7] METHOD FOR IN-SHOE SHEAR-STRESS MEASUREMENT
    LORD, M
    HOSEIN, R
    WILLIAMS, RB
    JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (03): : 181 - 186
  • [8] Reliability of an in-shoe pressure measurement system during treadmill walking
    Kernozek, TW
    LaMott, EE
    Dancisak, MJ
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (04) : 204 - 209
  • [9] Validity and repeatability of three commercially available in-shoe pressure measurement systems
    Carina Price
    Daniel Parker
    Christopher J Nester
    Journal of Foot and Ankle Research, 7 (Suppl 1)
  • [10] Comparison between an in-shoe pressure measuring system and a force plate: concurrent validity of body weight measurements
    Isakov, E
    Avni, A
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2004, 27 : 84 - 84