Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop

被引:13
|
作者
Christensen, Birgitte H. [1 ,2 ]
Andersen, Kathrine S. [1 ,3 ]
Pedersen, Kristina S. [3 ]
Bengtsen, Britt S. [3 ]
Simonsen, Ole [1 ]
Kappel, Simon L. [4 ]
Rathleff, Michael S. [1 ]
机构
[1] Aalborg Univ Hosp, Orthopaed Surg Res Unit, Aalborg, Denmark
[2] Aalborg Univ Hosp, Dept Occupat & Physiotherapy, Aalborg, Denmark
[3] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[4] Aarhus Univ, Aarhus Sch Engn, Signal Proc & Control Grp, Aarhus, Denmark
来源
关键词
Navicular drop; Foot kinematics; In-shoe; Stretch-sensor; FOOT MOBILITY; PAIN; KINEMATICS; AGREEMENT; PRONATION; ORTHOSES; INJURIES; EXERCISE; WALKING; TRIAL;
D O I
10.1186/1757-1146-7-12
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Increased navicular drop is associated with increased risk of lower extremity overuse injuries and foot orthoses are often prescribed to reduce navicular drop. For laboratory studies, transparent shoes may be used to monitor the effect of orthoses but no clinically feasible methods exist. We have developed a stretch-sensor that allows for in-shoe measurement of navicular drop but the reliability and validity is unknown. The purpose of this study was to investigate: 1) the reliability of the stretch-sensor for measuring navicular drop, and 2) the concurrent validity of the stretch-sensor compared to the static navicular drop test. Methods: Intra-and inter-rater reliability was tested on 27 participants walking on a treadmill on two separate days. The stretch-sensor was positioned 20 mm posterior to the tip of the medial malleolus and 20 mm posterior to the navicular tuberosity. The participants walked six minutes on the treadmill before navicular drop was measured. Reliability was quantified by the Intraclass Correlation Coefficient (ICC 2.1) and agreement was quantified by Limits of Agreement (LOA). To assess concurrent validity, static navicular drop was measured with the stretch-sensor and compared with static navicular drop measured with a ruler on 27 new participants. Linear regression was used to measure concurrent validity. Results: The reliability of the stretch-sensor was acceptable for barefoot measurement (intra-and inter-rater ICC: 0.76-0.84) but lower for in-shoe measurement (ICC: 0.65). There was a significant association between static navicular drop measured with the stretch-sensor compared with a ruler (r = 0.745, p < 0.001). Conclusion: This study suggests that the stretch-sensor has acceptable reliability for dynamic barefoot measurement of navicular drop. Furthermore, the stretch-sensor shows concurrent validity compared with the static navicular drop test as performed by Brody. This new simple method may hold promise for both clinical assessment and research but more work is needed before the method can be recommended.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Validity and Reliability of a Novel 3D Measurement Approach of the Acetabulum
    Martin, Charys M.
    Turgeon, James G.
    Rice, Charles L.
    Wilson, Timothy D.
    FASEB JOURNAL, 2012, 26
  • [32] Novel Method for Surface Tension Measurement: the Drop-Bounce Method
    Sun, Yifan
    Muta, Hiroaki
    Ohishi, Yuji
    MICROGRAVITY SCIENCE AND TECHNOLOGY, 2021, 33 (03)
  • [33] Concurrent validity and reliability of an iPhone app for the measurement of ankle dorsiflexion and inter-limb asymmetries
    Balsalobre-Fernandez, Carlos
    Romero-Franco, Natalia
    Jimenez-Reyes, Pedro
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (03) : 249 - 253
  • [34] Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
    Kim, Byong Hun
    Lee, Sae Yong
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (10)
  • [35] Development, Validity, and Reliability of a Novel Walking Speed Measurement Device: the GaitBox
    Jarvis, Leighanne M.
    Peterson, Matthew J.
    Caves, Kevin M.
    GAIT & POSTURE, 2021, 84 : 52 - 57
  • [36] RELIABILITY AND VALIDITY OF A NEW METHOD FOR THE MEASUREMENT OF TOTAL-BODY VOLUME
    KATCH, FI
    HORTOBAGYI, T
    DENAHAN, T
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1989, 60 (03) : 286 - 291
  • [37] Reliability, validity, and sex differences in a quantitative gag reflex measurement method
    Karibe, Hiroyuki
    Okamoto, Ayuko
    Kato, Yuichi
    Shimazu, Kisaki
    Goddard, Greg
    JOURNAL OF ORAL REHABILITATION, 2018, 45 (10) : 798 - 804
  • [38] A novel rapid measurement method of cervical sagittal parameters based on the integrated inclinometer of a smartphone: a validity and reliability study
    Huang, Tianji
    Zhang, Chunyang
    Han, Zhenghan
    Zhong, Weiyang
    Zhao, Zenghui
    Zhu, Yong
    Luo, Xiaoji
    Zhang, Jie
    ANNALS OF MEDICINE, 2023, 55 (02)
  • [39] Validity and Reliability of the Insole3 Instrumented Shoe Insole for Ground Reaction Force Measurement during Walking and Running
    Cramer, Leora A.
    Wimmer, Markus A.
    Malloy, Philip
    O'Keefe, Joan A.
    Knowlton, Christopher B.
    Ferrigno, Christopher
    SENSORS, 2022, 22 (06)
  • [40] Concurrent Validity and Reliability of a Novel Visual Analogue Fitness Perception Scale for Adolescents (FP VAS A)
    Mendoza-Munoz, Maria
    Adsuar, Jose C.
    Mendoza-Munoz, David Manuel
    Polero, Patricia
    Carlos-Vivas, Jorge
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (07)