Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop

被引:13
|
作者
Christensen, Birgitte H. [1 ,2 ]
Andersen, Kathrine S. [1 ,3 ]
Pedersen, Kristina S. [3 ]
Bengtsen, Britt S. [3 ]
Simonsen, Ole [1 ]
Kappel, Simon L. [4 ]
Rathleff, Michael S. [1 ]
机构
[1] Aalborg Univ Hosp, Orthopaed Surg Res Unit, Aalborg, Denmark
[2] Aalborg Univ Hosp, Dept Occupat & Physiotherapy, Aalborg, Denmark
[3] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[4] Aarhus Univ, Aarhus Sch Engn, Signal Proc & Control Grp, Aarhus, Denmark
来源
关键词
Navicular drop; Foot kinematics; In-shoe; Stretch-sensor; FOOT MOBILITY; PAIN; KINEMATICS; AGREEMENT; PRONATION; ORTHOSES; INJURIES; EXERCISE; WALKING; TRIAL;
D O I
10.1186/1757-1146-7-12
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Increased navicular drop is associated with increased risk of lower extremity overuse injuries and foot orthoses are often prescribed to reduce navicular drop. For laboratory studies, transparent shoes may be used to monitor the effect of orthoses but no clinically feasible methods exist. We have developed a stretch-sensor that allows for in-shoe measurement of navicular drop but the reliability and validity is unknown. The purpose of this study was to investigate: 1) the reliability of the stretch-sensor for measuring navicular drop, and 2) the concurrent validity of the stretch-sensor compared to the static navicular drop test. Methods: Intra-and inter-rater reliability was tested on 27 participants walking on a treadmill on two separate days. The stretch-sensor was positioned 20 mm posterior to the tip of the medial malleolus and 20 mm posterior to the navicular tuberosity. The participants walked six minutes on the treadmill before navicular drop was measured. Reliability was quantified by the Intraclass Correlation Coefficient (ICC 2.1) and agreement was quantified by Limits of Agreement (LOA). To assess concurrent validity, static navicular drop was measured with the stretch-sensor and compared with static navicular drop measured with a ruler on 27 new participants. Linear regression was used to measure concurrent validity. Results: The reliability of the stretch-sensor was acceptable for barefoot measurement (intra-and inter-rater ICC: 0.76-0.84) but lower for in-shoe measurement (ICC: 0.65). There was a significant association between static navicular drop measured with the stretch-sensor compared with a ruler (r = 0.745, p < 0.001). Conclusion: This study suggests that the stretch-sensor has acceptable reliability for dynamic barefoot measurement of navicular drop. Furthermore, the stretch-sensor shows concurrent validity compared with the static navicular drop test as performed by Brody. This new simple method may hold promise for both clinical assessment and research but more work is needed before the method can be recommended.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Monitoring in-shoe plantar pressures, temperature, and humidity: Reliability and validity of measures from a portable device
    Maluf, KS
    Morley, RE
    Richter, EJ
    Klaesner, JW
    Mueller, MJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (08): : 1119 - 1127
  • [12] Navicular drop measurement in people with rheumatoid arthritis: Interrater and intrarater reliability
    Shrader, JA
    Popovich, JM
    Gracey, GC
    Danoff, JV
    PHYSICAL THERAPY, 2005, 85 (07): : 656 - 664
  • [13] The Validity and Reliability of Navicular Angle Method in Measuring Foot Arch
    Yuan, Zhang J.
    Lin, Hui-Mei
    Tseng, Yu-Hua
    Fu, Szu-Kai
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 53 - 53
  • [14] Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement
    Bauer, C. M.
    Rast, F. M.
    Ernst, M. J.
    Kool, J.
    Oetiker, S.
    Rissanen, S. M.
    Suni, J. H.
    Kankaanpaa, M.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2015, 25 (05) : 782 - 790
  • [15] Reliability of the Pedar in-shoe system for plantar pressure measurement in diabetic patients with and without neuropathy: a prospective study
    Forogh, Bijan
    Raissi, Gholam Reza
    Soleymanzadeh, Hosnieh
    Cham, Masumeh Bagherzadeh
    CURRENT ORTHOPAEDIC PRACTICE, 2022, 33 (01): : 56 - 61
  • [16] Establishment of a measurement method for in-shoe pressure and shear stress in specific regions for diabetic ulcer prevention
    Amemiya, Ayumi
    Noguchi, Hiroshi
    Oe, Makoto
    Sanada, Hiromi
    Mori, Taketoshi
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2291 - 2294
  • [17] Quantitative measurement of hypertrophic scar: Interrater reliability and concurrent validity
    Nedelec, Bernadette
    Correa, Jose A.
    Rachelska, Grazyna
    Armour, Alexis
    LaSalle, Leo
    JOURNAL OF BURN CARE & RESEARCH, 2008, 29 (03): : 501 - 511
  • [18] A Novel Method to Determine Dynamic Temperature Trends Applied to In-Shoe Temperature Data During Walking
    Cutajar, L.
    Falzon, O.
    Mizzi, A.
    Swaine, I
    Springett, K.
    Mizzi, S.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3958 - 3961
  • [19] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [20] Radiographic Measurement of Rotational Deformity in Pelvic Fractures: A Novel Method With Validity and Reliability Testing
    Nystrom, Lukas M.
    McKinley, Todd O.
    Marsh, J. Lawrence
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (08) : 365 - 369