Reliability of the Pedar in-shoe system for plantar pressure measurement in diabetic patients with and without neuropathy: a prospective study

被引:0
|
作者
Forogh, Bijan [1 ]
Raissi, Gholam Reza [1 ]
Soleymanzadeh, Hosnieh [1 ]
Cham, Masumeh Bagherzadeh [1 ,2 ]
机构
[1] Iran Univ Med Sci, Firoozgar Hosp, Sch Med, Dept Phys Med & Rehabil,Neuromusculoskeletal Res, Tehran, Iran
[2] Iran Univ Med Sci, Fac Rehabil, Dept Orthot & Prosthet, Tehran, Iran
来源
CURRENT ORTHOPAEDIC PRACTICE | 2022年 / 33卷 / 01期
关键词
diabetes mellitus; peripheral neuropathy; reliability; Pedar in-shoe system; FOOT; INSOLES;
D O I
10.1097/BCO.0000000000001057
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aim of this study was to evaluate within and between days' reliability of the Pedar in-shoe system (Novel GmbH, Munich, Germany) to measure plantar pressure in diabetic patients with and without neuropathy. Methods: Forty-seven diabetic patients were divided into diabetic without neuropathy, and with mild, moderate, and severe neuropathy groups based on Toronto Clinical Neuropathy Score. Plantar pressure measurement was taken twice a day to assess within the same day's reliability and after a mean of 7 days to evaluate between different days' reliability. Results: Intraclass correlation coefficients (ICC) analysis indicated excellent reliability (ICC >= 0.75) in tests within the same day in all groups. Mean pressure and pressure time integral showed excellent levels of ICC reliability in the tests between different days' in the diabetic group without neuropathy and with mild neuropathy (ICC >= 0.75) and fair-to-excellent in the diabetic group with moderate and severe neuropathy (ICC >= 0.40). Reliability of contact area between different days were excellent in all groups (ICC >= 0.75). Conclusions: The results indicated that the Pedar in-shoe system was a reliable measure of plantar pressure within the same day and between different days in diabetic patients with and without neuropathy. The level of reliability was altered with a change of the neuropathy severity.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 50 条
  • [1] A study of in-shoe plantar shear in patients with diabetic neuropathy
    Lord, M
    Hosein, R
    CLINICAL BIOMECHANICS, 2000, 15 (04) : 278 - 283
  • [2] The Pedar® in-shoe system:: Repeatability and normal pressure values
    Putti, A. B.
    Arnold, G. P.
    Cochrane, L.
    Abboud, R. J.
    GAIT & POSTURE, 2007, 25 (03) : 401 - 405
  • [3] Reliability of in-shoe plantar pressure measurements in rheumatoid arthritis patients
    Vidmar, Gaj
    Novak, Primoz
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2009, 32 (01) : 36 - 40
  • [4] In-shoe plantar pressure measurement technologies for the diabetic foot: A systematic review
    Castro-Martins, Pedro
    Marques, Arcelina
    Coelho, Luis
    Vaz, Mario
    Baptista, Joao Santos
    HELIYON, 2024, 10 (09)
  • [5] Validity and reliability of the XSENSOR in-shoe pressure measurement system
    Parker, Daniel
    Andrews, Jennifer
    Price, Carina
    PLOS ONE, 2023, 18 (01):
  • [6] IN-SHOE PLANTAR MEASUREMENT WITH TEKSCAN SENSOR SYSTEM
    KOCH, M
    BIOMEDIZINISCHE TECHNIK, 1993, 38 (10): : 243 - 248
  • [7] Reliability of an in-shoe pressure measurement system during treadmill walking
    Kernozek, TW
    LaMott, EE
    Dancisak, MJ
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (04) : 204 - 209
  • [8] In-shoe Plantar Pressure Distribution in Nonneuropathic Type 2 Diabetic Patients in Singapore
    Tong, Jasper W. K.
    Acharya, U. Rajendra
    Chua, Kuang C.
    Tan, Peck H.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2011, 101 (06) : 509 - 516
  • [9] Barefoot and In-Shoe Plantar Pressure in a Portuguese Sample of Diabetic Patients: A Cross-Sectional Study
    Sousa, Liliana B.
    Bernardes, Rafael A.
    Almeida, Ines
    Ventura, Filipa
    Silva, Rosa
    Apostolo, Joao
    Baptista, Rui
    Salgueiro-Oliveira, Anabela
    Parreira, Pedro
    GERONTECHNOLOGY IV, 2022, : 257 - 266
  • [10] Reliability of F-Scan in-shoe measurements of plantar pressure
    Ahroni, JH
    Boyko, EJ
    Forsberg, R
    FOOT & ANKLE INTERNATIONAL, 1998, 19 (10) : 668 - 673