Dose conversion coefficients for CT examinations of adults with automatic tube current modulation

被引:32
|
作者
Schlattl, H. [1 ]
Zankl, M. [1 ]
Becker, J. [1 ]
Hoeschen, C. [1 ]
机构
[1] Helmholtz Zentrum Munchen, Natl Res Ctr Environm Hlth, Dept Med Radiat Phys & Diagnost, D-85764 Oberschleissheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 20期
关键词
AXIAL SCANNING TOMOGRAPHY; RADIATION-EXPOSURE; VOXEL MODELS; REDUCTION; FEMALE;
D O I
10.1088/0031-9155/55/20/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic tube current modulation (TCM) is used in modern CT devices. This is implemented in the numerical calculation of dose conversion coefficients for CT examinations. For four models of adults, the female and male reference models of ICRP and ICRU and a lighter and a heavier female model, dose conversion coefficients normalized to CTDIvol (DCCCT) have been computed with a Monte Carlo transport code for CT scans with and without TCM. It could be shown for both cases that reliable values for spiral CT scans are obtained when combining the results from an appropriate set of axial scans. The largest organ DCCCT are presented for typical CT examinations for all four models. The impact of TCM is greatest for chest, pelvis and whole-trunk CT examinations, where with TCM the effective DCCCT can be 20-25% lower than without TCM. Typical organs with strong dependence on TCM are thyroid, urinary bladder, lungs and oesophagus. While the DCCCT of thyroid and urinary bladder are mainly sensitive to angular TCM, the DCCCT of lungs and oesophagus are influenced primarily by longitudinal TCM. The impact of the body stature on the effective DCCCT is of the same order as the effect of TCM. Thus, for CT scans in the trunk region, accurate dose values can only be obtained when different sets of DCCCT are employed that are appropriate for the patient's sex and stature and the actual TCM settings.
引用
收藏
页码:6243 / 6261
页数:19
相关论文
共 50 条
  • [31] Prospective estimation of organ dose in CT under tube current modulation
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Samei, Ehsan
    MEDICAL PHYSICS, 2015, 42 (04) : 1575 - 1585
  • [32] Implementation of Tube Current Modulation into An Organ Dose Calculator for CT Patients
    Lee, C.
    Yeom, Y.
    Atkinson, J.
    Folio, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E264 - E264
  • [33] Patient Dose Monitoring in CT with Tube Current Modulation and Multiple Series
    Boone, J.
    Dixon, R.
    Li, B.
    Zhang, D.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E374 - E374
  • [34] VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Goto, T.
    Akahane, K.
    Ota, H.
    Tsukagoshi, S.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 508 - 517
  • [35] Attenuation-based Automatic Tube Voltage Selection and Tube Current Modulation for Dose Reduction at Contrast-enhanced Liver CT
    Lee, Kyung Hee
    Lee, Jeong Min
    Moon, Sung Kyoung
    Baek, Jee Hyun
    Park, Ji Hoon
    Flohr, Thomas G.
    Kim, Kyung Won
    Kim, Soo Jin
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2012, 265 (02) : 437 - 447
  • [36] Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    Rizzo, S
    Kalra, M
    Schmidt, B
    Dalal, T
    Suess, C
    Flohr, T
    Blake, M
    Saini, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 673 - 679
  • [37] A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs
    Chen, Wushuang
    Tang, Shilong
    Xu, Zhen
    Chen, Xin
    Zheng, Yinglan
    He, Ling
    IRANIAN JOURNAL OF RADIOLOGY, 2023, 20 (02)
  • [38] Characterization of radiation dose from tube current modulated CT examinations with considerations of both patient size and variable tube current
    Li, Xinhua
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2017, 44 (10) : 5413 - 5422
  • [39] Automatic tube-current modulation in CT -: A comparison between different solutions
    Althén, JN
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 308 - 312
  • [40] Evaluation of Changes in Dose Estimation on Abdomen CT Scan with Automatic Tube Current Modulation Using In-House Phantom
    Taopik, A.
    Lubis, L. E.
    Sihono, D. S. K.
    Soejoko, D. S.