Calibration update strategies for an array of potentiometric chemical sensors

被引:18
|
作者
Rudnitskaya, Alisa [1 ,2 ]
Costa, Ana Maria S. [2 ,3 ]
Delgadillo, Ivonne [2 ,3 ]
机构
[1] Univ Aveiro, CESAM, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Chem, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[3] Univ Aveiro, QOPNA, Campus Univ Santiago, P-3810193 Aveiro, Portugal
来源
关键词
Calibration update; Electronic tongue; Multivariate calibration standardization; Weighting; Tikhonov regularization; Joint-Y partial least square regression; MULTIVARIATE STANDARDIZATION; REGRESSION; MAINTENANCE; SELECTIVITY; VARIANTS; DESIGN;
D O I
10.1016/j.snb.2016.06.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the obstacles to the practical use of the multisensor systems - electronic tongues is a drift, i.e. gradual change of the sensor characteristics occurring in the process of their exploitation. Sensor drift leads to the deterioration of the performance of the calibration model that was calculated before changes in the sensor responses occurred. Two approaches can be employed to deal with this phenomenon. One consists of regular re-calibration of the sensor array, which is effective but time and labor consuming. Alternatively, multivariate statistical methods can be applied to the calibration model update using small subset of the standard samples. While significant efforts have been directed to the development of the calibration transfer and calibration update techniques, they were mostly applied to the near infrared spectroscopic instruments. Very few works addressed this issue for the potentiometric sensor arrays. In the present study, applicability of calibration update methods including slope and bias correction, direct standardization using PLS2 regression and auto-associative neural network, calibration update by weighting, Tikhonov regularization and Joint Y-PLS regression to the sensor array data was evaluated. Calibration models for copper and lead quantification in mixed solutions of transition metals using an array of 7 potentiometric sensors was used as an example. Of all studied methods, weighting and JYPLS regression were shown to be the most effective permitting to reduce prediction error for new data to the level of cross-validation error for the initial data. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1181 / 1189
页数:9
相关论文
共 50 条
  • [1] Detection of ultra-low activities of heavy metal ions by an array of potentiometric chemical sensors
    Alisa Rudnitskaya
    Andrey Legin
    Boris Seleznev
    Dmitri Kirsanov
    Yuri Vlasov
    Microchimica Acta, 2008, 163 : 71 - 80
  • [2] Detection of ultra-low activities of heavy metal ions by an array of potentiometric chemical sensors
    Rudnitskaya, Alisa
    Legin, Andrey
    Seleznev, Boris
    Kirsanov, Dmitri
    Vlasov, Yuri
    MICROCHIMICA ACTA, 2008, 163 (1-2) : 71 - 80
  • [3] On-the-field calibration of an array of sensors
    Dorveaux, Eric
    Vissiere, David
    Petit, Nicolas
    2010 AMERICAN CONTROL CONFERENCE, 2010, : 6795 - 6802
  • [4] Array of potentiometric sensors for multicomponent analysis of blood serum
    Correia, Daniela P. A.
    Magalhaes, Julia M. C. S.
    Machado, Adelio A. S. C.
    MICROCHIMICA ACTA, 2008, 163 (1-2) : 131 - 137
  • [5] Array of potentiometric sensors for multicomponent analysis of blood serum
    Daniela P. A. Correia
    Júlia M. C. S. Magalhães
    Adélio A. S. C. Machado
    Microchimica Acta, 2008, 163 : 131 - 137
  • [6] Array of potentiometric sensors for simultaneous analysis of urea and potassium
    Correia, DPA
    Magalhaes, JMCS
    Machado, AASC
    TALANTA, 2005, 67 (04) : 773 - 782
  • [7] Array of potentiometric sensors for the analysis of creatinine in urine samples
    Magalhaes, JMCS
    Machado, AASC
    ANALYST, 2002, 127 (08) : 1069 - 1075
  • [8] Electronic tongue based on an array of metallic potentiometric sensors
    Lvova, Larisa
    Martinelli, Eugenio
    Mazzone, Emiliano
    Pede, Andrea
    Paolesse, Roberto
    Di Natale, Corrado
    D'Amico, Arnaldo
    TALANTA, 2006, 70 (04) : 833 - 839
  • [9] Calibration strategies for the Cherenkov Telescope Array
    Gaug, Markus
    Berge, David
    Daniel, Michael
    Doro, Michele
    Foerster, Andreas
    Hofmann, Werner
    Maccarone, Maria Concetta
    Parsons, Dan
    Lopez, Raquel de los Reyes
    van Eldik, Christopher
    OBSERVATORY OPERATIONS: STRATEGIES, PROCESSES, AND SYSTEMS V, 2014, 9149
  • [10] An 'electronic tongue' system based on an array of metallic potentiometric sensors
    Lvova, L
    De Angelis, G
    Montieri, C
    Primadei, T
    Martinelli, E
    Mazzone, E
    Pede, A
    Paolesse, R
    Di Natale, C
    D'Amico, A
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 233 - 235