Array of potentiometric sensors for multicomponent analysis of blood serum

被引:7
|
作者
Correia, Daniela P. A. [1 ]
Magalhaes, Julia M. C. S. [1 ]
Machado, Adelio A. S. C. [1 ]
机构
[1] Univ Porto, Fac Ciencias, Dept Chem, LAQUIPAI, P-4169007 Oporto, Portugal
关键词
urea; potassium; carboxylated PVC; multicomponent analysis;
D O I
10.1007/s00604-007-0920-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two urea biosensors, based on carboxylated polyvinylchloride ammonium ion selective electrodes with urease immobilized with carbodiimide, were included in an array together with potassium and sodium ion selective electrodes and evaluated for simultaneous determination of urea and potassium in blood serum. The results show that it is possible to obtain principal component regression and partial least squares (PLS2) calibration models for simultaneous determination of urea (in the range 0.10-5 mM) and potassium (in the range 0.20-0.60 mM) based on a set of 9 calibration samples. The prediction errors of the concentration of urea and potassium in blood serum samples using this array and a PLS2 calibration model are lower than 13 and 5%, respectively.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 50 条
  • [1] Array of potentiometric sensors for multicomponent analysis of blood serum
    Daniela P. A. Correia
    Júlia M. C. S. Magalhães
    Adélio A. S. C. Machado
    Microchimica Acta, 2008, 163 : 131 - 137
  • [2] Array of potentiometric sensors for simultaneous analysis of urea and potassium
    Correia, DPA
    Magalhaes, JMCS
    Machado, AASC
    TALANTA, 2005, 67 (04) : 773 - 782
  • [3] Array of potentiometric sensors for the analysis of creatinine in urine samples
    Magalhaes, JMCS
    Machado, AASC
    ANALYST, 2002, 127 (08) : 1069 - 1075
  • [4] New potentiometric sensors with crystalline membranes based on diethyldithiocarbamates for multicomponent analysis
    Vlasov, YG
    Ermolenko, YE
    Legin, AV
    Murzina, YG
    EUROSENSORS XII, VOLS 1 AND 2, 1998, : 751 - 754
  • [5] MULTICOMPONENT ANALYSIS USING AN ARRAY OF PIEZOELECTRIC CRYSTAL SENSORS
    CAREY, WP
    BEEBE, KR
    KOWALSKI, BR
    ANALYTICAL CHEMISTRY, 1987, 59 (11) : 1529 - 1534
  • [6] Calibration update strategies for an array of potentiometric chemical sensors
    Rudnitskaya, Alisa
    Costa, Ana Maria S.
    Delgadillo, Ivonne
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 1181 - 1189
  • [7] Electronic tongue based on an array of metallic potentiometric sensors
    Lvova, Larisa
    Martinelli, Eugenio
    Mazzone, Emiliano
    Pede, Andrea
    Paolesse, Roberto
    Di Natale, Corrado
    D'Amico, Arnaldo
    TALANTA, 2006, 70 (04) : 833 - 839
  • [8] Wideband spectral matrix filtering for multicomponent sensors array
    Paulus, C
    Mars, J
    Gounon, P
    SIGNAL PROCESSING, 2005, 85 (09) : 1723 - 1743
  • [9] MODELING OF POTENTIOMETRIC ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS
    FORSTER, RJ
    REGAN, F
    DIAMOND, D
    ANALYTICAL CHEMISTRY, 1991, 63 (09) : 876 - 882
  • [10] An 'electronic tongue' system based on an array of metallic potentiometric sensors
    Lvova, L
    De Angelis, G
    Montieri, C
    Primadei, T
    Martinelli, E
    Mazzone, E
    Pede, A
    Paolesse, R
    Di Natale, C
    D'Amico, A
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 233 - 235