Array of potentiometric sensors for multicomponent analysis of blood serum

被引:7
|
作者
Correia, Daniela P. A. [1 ]
Magalhaes, Julia M. C. S. [1 ]
Machado, Adelio A. S. C. [1 ]
机构
[1] Univ Porto, Fac Ciencias, Dept Chem, LAQUIPAI, P-4169007 Oporto, Portugal
关键词
urea; potassium; carboxylated PVC; multicomponent analysis;
D O I
10.1007/s00604-007-0920-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two urea biosensors, based on carboxylated polyvinylchloride ammonium ion selective electrodes with urease immobilized with carbodiimide, were included in an array together with potassium and sodium ion selective electrodes and evaluated for simultaneous determination of urea and potassium in blood serum. The results show that it is possible to obtain principal component regression and partial least squares (PLS2) calibration models for simultaneous determination of urea (in the range 0.10-5 mM) and potassium (in the range 0.20-0.60 mM) based on a set of 9 calibration samples. The prediction errors of the concentration of urea and potassium in blood serum samples using this array and a PLS2 calibration model are lower than 13 and 5%, respectively.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 50 条
  • [31] Application of a potentiometric sensor array as a technique in sensory analysis
    Hruskar, M.
    Major, N.
    Krpan, M.
    TALANTA, 2010, 81 (1-2) : 398 - 403
  • [32] IMMUNOCHEMICAL POTENTIOMETRIC SENSORS
    JANATA, J
    BLACKBURN, GF
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 428 (JUN) : 286 - 292
  • [33] POTENTIOMETRIC ENZYMATIC SENSORS
    KONCKI, R
    GLAB, S
    CHEMIA ANALITYCZNA, 1991, 36 (03): : 423 - 446
  • [34] Immunoreactions in potentiometric sensors
    Kazimierczak, B
    Baraniecka, A
    Pijanowska, D
    Dawgul, M
    Kruk, J
    Krzysków, A
    Torbicz, W
    OPTICAL TECHNIQUES FOR ENVIRONMENTAL SENSING, WORKPLACE SAFETY, AND HEALTH MONITORING, 2002, 4887 : 137 - 140
  • [35] POTENTIOMETRIC ENZYME SENSORS
    VANDERSCHOOT, BH
    BERGVELD, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (4-5): : 335 - 335
  • [36] POTENTIOMETRIC GLUCOSE SENSORS
    HONOLD, F
    CAMMANN, K
    HORMONE AND METABOLIC RESEARCH, 1988, 20 : 47 - 49
  • [37] Potentiometric ion sensors
    Bobacka, Johan
    Ivaska, Ari
    Lewenstam, Andrzej
    CHEMICAL REVIEWS, 2008, 108 (02) : 329 - 351
  • [38] A CMOS Integrable DDCCII-Based Readout System For Portable Potentiometric Sensors Array
    Ferri, G.
    Stornelli, V.
    Di Carlo, C.
    De Marcellis, A.
    D'Amico, A.
    Di Natale, C.
    Martinelli, E.
    OLFACTION AND ELECTRONIC NOSE, PROCEEDINGS, 2009, 1137 : 310 - +
  • [39] Beer classification based on the array of solid-contact potentiometric sensors with thiacalixarene receptors
    E. E. Stoikova
    N. N. Dolgova
    A. A. Savel’ev
    A. V. Galukhin
    I. I. Stoikov
    I. S. Antipin
    G. A. Evtyugin
    Russian Chemical Bulletin, 2014, 63 : 223 - 231
  • [40] DIRECT POTENTIOMETRIC DETERMINATION OF POTASSIUM AND SODIUM IN BLOOD, SERUM, AND URINE
    MIYADA, DS
    INAMI, K
    MATSUYAM.G
    CLINICAL CHEMISTRY, 1970, 16 (06) : 528 - &